View larger
PT 2X1-24DC-ST 2856087 PHOENIX CONTACT Surge protection plug
PT 2X1-24DC-ST
2856087
PHOENIX CONTACT
1 Pcs.
Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for easy maintenance, the Phoenix Contact PT 2X1-24DC-ST surge protection plug securely clips into compatible base elements to defend instrumentation lines from transient voltages. Facilities rely on pluggable surge suppressors to minimize downtime during routine maintenance and component replacements. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Nominal voltage DC (EF008799): 24 V
More info
▲Key Commercial Data
| Orderkey | 2856087 |
|---|---|
| Packing unit | 10 pc |
| Catalog page | Page 112 (C-4-2017) |
| GTIN | 4017918599164 |
| Weight per Piece (excluding packing) | 20.100 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
Dimensions
| Height | 44.8 mm |
|---|---|
| Width | 17.5 mm |
| Depth | 51.7 mm |
| Horizontal pitch | 1 Div. |
| Complete module height | 90 mm |
| Complete module width | 17.7 mm |
| Complete module depth | 65.5 mm |
General
| Housing material | PA 6.6 |
|---|---|
| Flammability rating according to UL 94 | V-0 |
| Color | black |
| Standards for cearances and creepage distances | VDE 0110-1 |
| IEC 60664-1 | |
| Mounting type | on base element |
| Type | Male |
| Direction of action | Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground |
| Arrester can be tested with CHECKMASTER from software version: | From SW rev. 1.00 |
Protective circuit
| IEC test classification | C1 |
|---|---|
| C2 | |
| C3 | |
| D1 | |
| VDE requirement class | C1 |
| C2 | |
| C3 | |
| D1 | |
| Nominal voltage UN | 24 V DC |
| Maximum continuous voltage UC | 28 V DC |
| 20 V AC | |
| Rated current | 300 mA (45°C) |
| Operating effective current ICat UC | ≤ 5 µA |
| Residual current IPE | ≤ 1 µA (with PT 2X1+F-BE) |
| ≤ 10 µA (Directly grounded) | |
| Nominal discharge current In(8/20) µs (line-earth) | 10 kA |
| Pulse discharge current Iimp(10/350) µs | 2.5 kA (per path) |
| Total discharge current Itotal(8/20) µs | 20 kA |
| Max. discharge current Imax(8/20) µs maximum (line-earth) | 10 kA |
| Nominal pulse current Ian (10/1000) µs (line-earth) | 30 A |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 45 V |
| ≤ 600 V (with PT 2X1+F-BE) | |
| Output voltage limitation at 1 kV/µs (line-earth) static | ≤ 40 V |
| Residual voltage at In(line-earth) | ≤ 40 V |
| Residual voltage with Ian (10/1000) µs (line-earth) | ≤ 50 V |
| Voltage protection level Up(line-earth) | ≤ 60 V (C1 - 1 kV/500 A) |
| ≤ 80 V (C2 - 10 kV / 5 kA) | |
| ≤ 70 V (6 kV / 3 kA) | |
| ≤ 50 V (C3 - 30 A) | |
| Response time tA(line-earth) | ≤ 1 ns |
| Input attenuation aE, asym. | 0.5 dB (≤ 1 MHz) |
| 0.3 dB (≤ 400 kHz / 150 Ω) | |
| Cut-off frequency fg (3 dB), asym. (PE) in 50 Ohm system | typ. 4.5 MHz |
| Capacity (line-earth) | typ. 0.7 nF |
| Resistance in series | 4.7 Ω ±10 % (7-8/11-12) |
| Surge protection fault message | none |
| Max. required back-up fuse | 315 mA (T) |
| Impulse durability (line-earth) | C2 - 10 kV/5 kA |
| D1 - 2.5 kA |
Connection data
| Connection method | Screw connection (in connection with the base element) |
|---|---|
| Screw thread | M3 |
| Tightening torque | 0.8 Nm |
| Stripping length | 8 mm |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 12 |
Connection, equipotential bonding
| Stripping length | 8 mm |
|---|---|
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 4 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |