Request QuoteProduct Overview
A Surge protection plug like the Phoenix Contact PT 2X1-24AC/FM-ST offers modular, pluggable transient voltage suppression for automation control networks and instrumentation circuits. These replaceable connector modules interface with dedicated base elements in electrical distribution boards to shield delicate automation electronics against line-side voltage spikes without requiring complete rewiring during maintenance cycles.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2920146
- Packing unit: 10 pc
- Note: Made to Order (non-returnable)
- Catalog page: Page 91 (TT-2011)
- GTIN: 4046356154062
- Weight per Piece (excluding packing): 27.540 g
- Custom tariff number: 85363010
- Country of origin: DE (Germany)
- Utilization restriction: EMC: class A product, see manufacturer's declaration in the download area
- Height: 44.8 mm
- Width: 17.5 mm
- Depth: 51.7 mm
- Horizontal pitch: 1 Div.
- Complete module height: 90 mm
- Complete module width: 17.7 mm
- Complete module depth: 65.5 mm
More info
▲Key Commercial Data
| Orderkey | 2920146 |
|---|---|
| Packing unit | 10 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 91 (TT-2011) |
| GTIN | 4046356154062 |
| Weight per Piece (excluding packing) | 27.540 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Dimensions
| Height | 44.8 mm |
|---|---|
| Width | 17.5 mm |
| Depth | 51.7 mm |
| Horizontal pitch | 1 Div. |
| Complete module height | 90 mm |
| Complete module width | 17.7 mm |
| Complete module depth | 65.5 mm |
General
| Housing material | PA 6.6 |
|---|---|
| Flammability rating according to UL 94 | V-0 |
| Color | black |
| Standards for cearances and creepage distances | VDE 0110-1 |
| IEC 60664-1 | |
| Mounting type | on base element |
| Type | Male |
| Direction of action | Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground |
Protective circuit
| IEC test classification | C1 |
|---|---|
| C2 | |
| C3 | |
| D1 | |
| VDE requirement class | C1 |
| C2 | |
| C3 | |
| D1 | |
| Nominal voltage UN | 24 V AC |
| Maximum continuous voltage UC | 40 V DC |
| 28 V AC | |
| Rated current | 300 mA (45°C) |
| Operating effective current ICat UC | ≤ 5 µA |
| Residual current IPE | ≤ 1 µA (with PT 2X1+F-BE) |
| ≤ 10 µA (Directly grounded) | |
| Nominal discharge current In(8/20) µs (line-earth) | 10 kA |
| Pulse discharge current Iimp(10/350) µs | 2.5 kA (per path) |
| Total discharge current Itotal(8/20) µs | 20 kA |
| Max. discharge current Imax(8/20) µs maximum (line-earth) | 10 kA |
| Nominal pulse current Ian (10/1000) µs (line-earth) | 23 A (25 °C) |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 70 V |
| Output voltage limitation at 1 kV/µs (line-signalground) spike | ≤ 70 V |
| Output voltage limitation at 1 kV/µs (line-earth) static | ≤ 55 V |
| Output voltage limitation at 1 kV/µs (line-signalground) static | ≤ 55 V |
| Residual voltage at In(line-earth) | ≤ 55 V |
| Residual voltage with Ian (10/1000) µs (line-earth) | ≤ 65 V |
| Voltage protection level Up(line-earth) | ≤ 55 V (C1 - 500 V / 250 A) |
| ≤ 55 V (C3 - 25 A) | |
| Voltage protection level Up(line-signalground) | ≤ 55 V (C1 - 500 V / 250 A) |
| ≤ 55 V (C3 - 25 A) | |
| Response time tA(line-earth) | ≤ 1 ns |
| Input attenuation aE, asym. | typ. 0.5 dB (≤ 1.5 MHz / 50 Ω) |
| typ. 0.2 dB (≤ 500 kHz / 150 Ω) | |
| Cut-off frequency fg (3 dB), asym. (GND) in 50 Ohm system | typ. 8 MHz |
| Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm system | typ. 3 MHz |
| Resistance in series | 4.7 Ω (7-8/11-12) |
| Surge protection fault message | Optical, remote indicator contact |
| Max. required back-up fuse | 315 mA (T) |
| Impulse durability (line-earth) | C2 - 10 kV/5 kA |
| D1 - 2.5 kA | |
| C3 - 10 A | |
| Alternating current carrying capacity (line-earth) | 5 A - 1 s |
Connection data
| Connection method | Screw connection (in connection with the base element) |
|---|---|
| Screw thread | M3 |
| Tightening torque | 0.8 Nm |
| Stripping length | 8 mm |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 12 |
Remote indication contact
| Switching function | N/C contact |
|---|---|
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Maximum operating voltage Umax.AC | 250 V AC |
| Max. operating current Imax | 0.2 A (250 V AC) |
| 0.2 A (220 V DC) | |
| 1 A (60 V AC) | |
| 1 A (60 V DC) |
Standards and Regulations
| Standards/regulations | IEC 61643-21 |
|---|---|
| DIN EN 61643-21 | |
| Standards/specifications | IEC 61643-21 2002 |