View larger
CT 10-18FS+F/PE-24 2807926 PHOENIX CONTACT Surge protection plug
CT 10-18FS+F/PE-24
2807926
PHOENIX CONTACT
1 Pcs.
Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Operating as a surge protection plug, the Phoenix Contact CT 10-18FS+F/PE-24 2807926 effectively diverts high-voltage transients away from industrial automation electronics. These modular plugs are widely used in modular terminal block setups to maintain operational safety and protect signal lines from electrical noise and surges. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Nominal voltage DC (EF008799): 24 V
More info
▲Key Commercial Data
| Orderkey | 2807926 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 107 (C-6-2013) |
| GTIN | 4017918075408 |
| Weight per Piece (excluding packing) | 106.510 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 75 °C |
|---|---|
| Altitude | ≤ 2000 mm (amsl (above mean sea level)) |
| Degree of protection | IP20 |
General
| Housing material | PBT |
|---|---|
| Flammability rating according to UL 94 | V-0 |
| Color | jet black RAL 9005 |
| Standards for cearances and creepage distances | VDE 0110-1 |
| Mounting type | On CT-TERMIBLOCK and LSA-PLUS disconnect strip |
| Type | LSA-PLUS module |
| Direction of action | Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground |
| Arrester can be tested with CHECKMASTER from software version: | From SW rev. 1.00 |
Protective circuit
| IEC test classification | C1 |
|---|---|
| C2 | |
| C3 | |
| D1 | |
| Nominal voltage UN | 24 V DC |
| 24 V AC | |
| Maximum continuous voltage UC | 40 V DC |
| 28 V AC | |
| Rated current | 1.5 A AC (75 °C) |
| 350 mA DC (75 °C) | |
| Operating effective current ICat UC | ≤ 5 µA (18x) |
| Residual current IPE | ≤ 1 µA (19x) |
| Nominal discharge current In(8/20) µs (line-line) | 119 A (per path) |
| Nominal discharge current In(8/20) µs (line-earth) | 5 kA (per path) |
| Nominal discharge current In(8/20) µs (signalground-earth) | 5 kA (per path) |
| Pulse discharge current Iimp(10/350) µs (line-earth) | 2.5 kA |
| Pulse discharge current Iimp(10/350) µs (signalground-earth) | 2.5 kA |
| Total discharge current Itotal(8/20) µs | 10 kA |
| Max. discharge current Imax(8/20) µs maximum (line-line) | 119 A (per path) |
| Max. discharge current Imax(8/20) µs maximum (line-earth) | 5 kA (per path) |
| Nominal pulse current Ian (10/1000) µs (line-signalground) | 23 A |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 650 V |
| Output voltage limitation at 1 kV/µs (line-signalground) spike | ≤ 70 V |
| Output voltage limitation at 1 kV/µs (line-signalground) static | ≤ 60 V |
| Residual voltage at In(line-earth) | ≤ 30 V |
| Residual voltage at In(line-signalground) | ≤ 85 V |
| Residual voltage with Ian (10/1000) µs (line-signalground) | ≤ 65 V |
| Response time tA (line-signalground) | ≤ 1 ns |
| Response time tA(line-earth) | ≤ 100 ns |
| Input attenuation aE, asym. | typ. 0.1 dB (≤ 2 MHz / 50 Ω) |
| typ. 0.1 dB (≤ 200 kHz / 150 Ω) | |
| typ. 0.1 dB (≤ 80 kHz / 600 Ω) | |
| Cut-off frequency fg (3 dB), asym. (GND) in 50 Ohm system | typ. 10 MHz |
| Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm system | typ. 2.5 MHz |
| Cut-off frequency fg (3 dB), asym. (GND) in 600 Ohm system | typ. 650 kHz |
| Capacity (line-signalground) | typ. 1.1 nF (1 MHz) |
| Surge protection fault message | none |
| Impulse durability (line-earth) | C2 - 10 kV/5 kA |
| D1 - 2.5 kA | |
| Impulse durability (line-signalground) | C3 - 23 A |
| Impulse durability (signalground-earth) | D1 - 2.5 kA |
Connection data
| Connection method | can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips |
|---|---|
| Connection method IN | COMTRAB plug-in system |
| Connection method OUT | COMTRAB plug-in system |
Standards and Regulations
| Standards/specifications | IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012 |
|---|---|
| EN 61643-21 2001 + A1:2009 + A2:2013 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |