PHOENIX CONTACT C-SAT-BOX C-SAT-BOX 2880561 PHOENIX CONTACT Surge protection device View larger
Images are for illustrative purposes only. Please refer to data sheet for details

C-SAT-BOX 2880561 PHOENIX CONTACT Surge protection device

C-SAT-BOX

2880561

PHOENIX CONTACT

1 Pcs.

Surge protection device Surge protection for antenna splitters in satellite installations. IN and OUT via F connectors, 5 channels for signals from satellite installations and terrestrial antennas, grounding on the outside of the housing.

Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Serving as a surge protection device, the Phoenix Contact C-SAT-BOX 2880561 protects sensitive measurement and control electronics from damaging voltage transients. Industrial installations rely on these components to absorb high-energy surges on signal paths, preventing costly downtime and equipment failure in automated infrastructure. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Nominal voltage AC (EF008798): 14 V

More info

▲

Key Commercial Data

Orderkey2880561
Packing unit1 pc
Catalog pagePage 180 (C-4-2017)
GTIN4046356048941
Weight per Piece (excluding packing)228.240 g
Custom tariff number85363010
Country of originDE (Germany)

Dimensions

Height31.5 mm
Width144.9 mm
Depth71.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 4000 m (amsl (above mean sea level))
Degree of protectionIP40

General

Housing materialZinc die-cast
Colorsilver
Standards for cearances and creepage distancesIEC 60664-1
DIN VDE 0110-1
Overvoltage categoryII
Degree of pollution2
Mounting typeScrew mounting
TypeHousing for surface mounting
Number of positions5
Direction of actionLine-Shield/Earth Ground

Protective circuit

IEC test classificationB2
C1
C2
C3
D1
Nominal voltage UN14 V DC (vertical)
18 V DC (horizontal)
Maximum continuous voltage UC20 V DC
Rated current400 mA
Operating effective current ICat UC≤ 2 µA (per channel)
Residual current IPE≤ 2 µA (per channel)
Nominal discharge current In(8/20) µs (line-shield)2.5 kA
Total discharge current Itotal(8/20) µs10 kA
Max. discharge current Imax(8/20) µs maximum (line-shield)2.5 kA
Nominal pulse current Ian (10/1000) µs (Core-Shield)100 A
Nominal pulse current Ian (10/700) µs (Core-Shield)100 A
Output voltage limitation at 1 kV/µs (line-shield) static≤ 80 V
Voltage protection level Up(line-shield)≤ 500 V (C2 - 4 kV / 2 kA)
≤ 120 V (C3 - 100 A)
Response time tA (line-shield)≤ 1 ns
Input attenuation aE, asym.≤ 1 dB (5 MHz ... 2,2 GHz / 75 Ω)
≤ 3 dB (5 MHz ... 2,4 GHz / 75 Ω)
Near-end crosstalk attenuation≥ 40 dB (5 MHz ... 2,4 GHz / 75 Ω)
Cut-off frequency fg (3 dB), asym. (shield) in 75 Ohm system> 2.5 GHz
Frequency range47 MHz ... 2.5 GHz
Inductivity in seriestyp. 5 µH (f = 10 kHz)
Resistance in series3.3 Ω ±20 %
Surge protection fault messagenone
Impulse durability (line-shield)B2 - 4 kV/100 A
C1 - 1 kV/500 A
C2 - 4 kV/2 kA
C3 - 100 A
D1 - 500 A
Impulse durability (shield-earth)C2 - 10 kA
D1 - 5 kA

Connection data

Connection methodF connector
Connection method INF connector, female
Connection method OUTF connector, female

Connection, equipotential bonding

Connection methodScrew connection

Standards and Regulations

Standards/specificationsIEC 61643-21 2000 + A1:2008 + A2:2012
EN 61643-21 2013
EN 50083-2 CLASS-A

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.