PHOENIX CONTACT VAL-MS 60/FM VAL-MS 60/FM 2868033 PHOENIX CONTACT Type 2 surge arrester View larger
Images are for illustrative purposes only. Please refer to data sheet for details

VAL-MS 60/FM 2868033 PHOENIX CONTACT Type 2 surge arrester

VAL-MS 60/FM

2868033

PHOENIX CONTACT

1 Pcs.

Type 2 surge arrester Surge arrester consisting of a base element with FM remote indication contact and a prot. plug. with high-power varistor, for mounting on NS 35/7.5, 1 channel Surge arrester consisting of base element with remote indicator contact and protective connector with high-capacity varistor, for mounting on NS 35/7.5, 1-channel

Automation > Surge protection device for power supply systems
Trabtech (TT)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact VAL-MS 60/FM Type 2 surge arrester is utilized in industrial automation environments to limit surge voltages and protect electrical machinery from transient disturbances. Installed within main or sub-distribution enclosures, this component helps ensure reliable power quality and minimizes downtime risks. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Product type: Surge arrester
  • Product family: VALVETRAB MS
  • IEC test classification: II
  • EN type: T2
  • IEC power supply system: TN
  • Type: DIN rail module, two-section, divisible
  • Number of positions: 1
  • Surge protection fault message: Optical, remote indicator contact
  • Data management status Article revision: 13
  • Insulation characteristics Overvoltage category: III
  • Pollution degree: 2
  • Nominal frequency f N: 50 Hz (60 Hz)
  • Indicator/remote signaling Connection name: Remote fault indicator contact
  • Switching function: Changeover contact
  • Operating voltage: 5 V AC ... 250 V AC
  • Operating current: 5 mA AC ... 1 A AC

More info

▲
Technical data

Product properties
Product typeSurge arrester
Product familyVALVETRAB MS
IEC test classificationII
T2
EN typeT2
IEC power supply systemTN
TypeDIN rail module, two-section, divisible
Number of positions1
Surge protection fault messageOptical, remote indicator contact
Data management status
Article revision13
Insulation characteristics
Overvoltage categoryIII
Pollution degree2

Electrical properties
Nominal frequency fN50 Hz (60 Hz)
Indicator/remote signaling
Connection nameRemote fault indicator contact
Switching functionChangeover contact
Operating voltage5 V AC ... 250 V AC
30 V DC
Operating current5 mA AC ... 1 A AC
1 A DC

Connection data
Connection methodScrew connection
Screw threadM5
Tightening torque3 Nm (1.5 mm² ... 16 mm²)
4.5 Nm (25 mm² ... 35 mm²)
Stripping length16 mm
Conductor cross section flexible1.5 mm² ... 25 mm²
Conductor cross section rigid1.5 mm² ... 35 mm²
Conductor cross section AWG15 ... 2
Connection methodFork-type cable lug
Conductor cross section flexible1.5 mm² ... 16 mm²
Remote fault indicator contact
Connection methodPlug-in/screw connection via COMBICON
Screw threadM2
Tightening torque0.25 Nm
Stripping length7 mm
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16

Dimensions
Dimensional drawing
Width17.6 mm
Height98.8 mm
Depth65.7 mm (incl. DIN rail 7.5 mm)
Horizontal pitch1 Div.

Material specifications
Colorblack (RAL 9005)
Flammability rating according to UL 94V-0
CTI value of material600
Insulating materialPA 6.6/PBT
Material groupI
Housing materialPA 6.6
PBT

Protective circuit
Mode of protectionL-PEN
Direction of action1L-N/PE
Nominal voltage UN60 V AC (TN)
60 V DC
-48 V DC (RRH)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC75 V AC
100 V DC
Rated load current IL80 A
Residual current IPE≤ 0.45 mA
Standby power consumption PC≤ 35 mVA
Nominal discharge current In(8/20) µs15 kA
Maximum discharge current Imax(8/20) µs40 kA
Short-circuit current rating ISCCR25 kA
Voltage protection level Up≤ 0.55 kV
Residual voltage Ures≤ 0.55 kV (at In)
≤ 0.425 kV (at 10 kA)
≤ 0.325 kV (at 5 kA)
≤ 0.275 kV (at 3 kA)
TOV behavior at UT100 V AC (5 s / withstand mode)
Response time tA≤ 25 ns
Max. backup fuse with V-type through wiring80 A AC (gG)
Max. backup fuse with branch wiring125 A AC (gG)
50 A DC (gG)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl)
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

Approvals
UL specifications
Maximum continuous operating voltage MCOV (L-N)75 V AC
Maximum continuous operating voltage MCOV (L+) - (L-)100 V DC
Nominal discharge current In(L-N)10 kA
Nominal discharge current In(L+) - (L-)10 kA
Mode of protectionL-N
(L+) - (L-)
Nominal voltage60 V AC
Nominal voltage60 V DC
Power distribution systemSingle phase
Nominal frequency50/60 Hz
Measured limiting voltage MLV (L-N)630 V
Measured limiting voltage MLV (L+) - (L-)810 V
SPD Type4CA
UL indicator/remote signaling
Operating voltage125 V AC
AC operating current1 A AC
UL connection data
Tightening torque30 lbf-in.
Conductor cross section AWG14 ... 2

Standards and regulations
Standards/specificationsIEC 61643-11
Note2011
Standards/specificationsEN 61643-11