View larger
ST-REL3-SG-B 24/21/M 2898155 PHOENIX CONTACT Relay connectors
ST-REL3-SG-B 24/21/M
2898155
PHOENIX CONTACT
1 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact ST-REL3-SG-B 24/21/M Relay connectors unit is engineered to provide secure plug-and-play signal switching within complex automation architectures. These modular relay connectors facilitate rapid installation and efficient maintenance inside industrial control systems.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product type: Relay Module
- Operating mode: 100% operating factor
- Mechanical service life: approx. 10 7 cycles
- Data management status Date of last data management: 02.05.2024
- Article revision: 09
- Overvoltage category: II
- Pollution degree: 2
- Maximum power dissipation for nominal condition: 0.19 W
- Test voltage (Winding/contact): 2 kV rms (50 Hz, 1 min., winding/contact)
- Rated surge voltage: 2.5 kV
- Coil side Nominal input voltage U N: 24 V DC
- Input voltage range: 19.2 V DC ... 26.4 V DC (20 °C)
- Drive and function: bistable
- Drive (polarity): polarized
- Typical input current at U N: typ. 8 mA
- Typical response time: 5 ms
More info
▲| Product type | Relay Module |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 107cycles |
| Data management status | |
| Date of last data management | 02.05.2024 |
| Article revision | 09 |
| Insulation characteristics: Air clearances and creepage distances between the power circuits | |
| Insulation | Basic insulation |
| Overvoltage category | II |
| Pollution degree | 2 |
| Maximum power dissipation for nominal condition | 0.19 W |
| Test voltage (Winding/contact) | 2 kVrms(50 Hz, 1 min., winding/contact) |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 2.5 kV |
| Coil side | |
| Nominal input voltage UN | 24 V DC |
| Input voltage range | 19.2 V DC ... 26.4 V DC (20 °C) |
| Drive and function | bistable |
| Drive (polarity) | polarized |
| Typical input current at UN | typ. 8 mA |
| Typical response time | 5 ms |
| Typical release time | 5 ms |
| Pulse time range | 30 ms ... 5 s |
| Coil voltage | 24 V DC |
| Protective circuit | Freewheeling diode; Freewheeling diode |
| Reverse polarity protection; Polarity protection diode | |
| Switching | |
| Contact switching type | 1 changeover contact |
| Type of switch contact | Single contact |
| Contact material | AgSnO |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 5 V (At 5 V) |
| 24 V (at 24 V) | |
| Limiting continuous current | 6 A |
| Maximum inrush current | 8 A |
| Min. switching current | 1 mA (at 24 V) |
| 100 mA (At 5 V) | |
| Interrupting rating (ohmic load) max. | 144 W (at 24 V DC) |
| 43 W (at 48 V DC) | |
| 42 W (at 60 V DC) | |
| 55 W (at 110 V DC) | |
| 100 W (at 220 V DC) | |
| 1500 VA (for 250 V AC) | |
| Switching: when the gold layer is destroyed | |
| Maximum switching voltage | 250 V AC/DC |
| Limiting continuous current | 6 A |
| Maximum inrush current | 8 A |
| Interrupting rating (ohmic load) max. | 120 W (at 24 V DC) |
| 40 W (at 48 V DC) | |
| 35 W (at 60 V DC) | |
| 30 W (at 110 V DC) | |
| 55 W (at 220 V DC) | |
| 1500 VA (for 250 V AC) | |
| Width | 20.8 mm |
| Height | 33 mm |
| Depth | 66.5 mm |
| Color | green (RAL 6021) |
| Ambient conditions | |
| Ambient temperature (operation) | -40 °C ... 50 °C |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | DIN EN 50178 |
| Mounting type | Plug-in mounting |
| Assembly note | in rows with zero spacing |
| Mounting position | any |