Engineered as a compact relay module, the Phoenix Contact ST-REL3-KG 24/21AU provides dependable signal conditioning and electrical isolation between control systems and industrial actuators. These interface modules prevent ground loops and protect sensitive logic boards from high-voltage transients.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Relay Module
- Operating mode: 100% operating factor
- Mechanical service life: approx. 2x 10 7 cycles
- Data management status Date of last data management: 02.05.2024
- Article revision: 05
- Maximum power dissipation for nominal condition: 0.5 W
- Test voltage (Winding/contact): 2.5 kV AC (50 Hz, 1 min., winding/contact)
- Coil side Nominal input voltage U N: 24 V AC/DC
- Input voltage range: 19.2 V AC/DC ... 26.4 V AC/DC (20 °C)
- Drive and function: monostable
- Drive (polarity): polarized
- Typical input current at U N: 21 mA
- Typical response time: 7 ms
- Typical release time: 11 ms (with DC)
- Protective circuit: Bridge rectifier, varistor
- Operating voltage display: yes
More info
▲| Product type | Relay Module |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 2x 107cycles |
| Data management status | |
| Date of last data management | 02.05.2024 |
| Article revision | 05 |
| Maximum power dissipation for nominal condition | 0.5 W |
| Test voltage (Winding/contact) | 2.5 kV AC (50 Hz, 1 min., winding/contact) |
| Coil side | |
| Nominal input voltage UN | 24 V AC/DC |
| Input voltage range | 19.2 V AC/DC ... 26.4 V AC/DC (20 °C) |
| Drive and function | monostable |
| Drive (polarity) | polarized |
| Typical input current at UN | 21 mA |
| Typical response time | 7 ms |
| Typical release time | 11 ms (with DC) |
| Protective circuit | Bridge rectifier, varistor |
| Operating voltage display | yes |
| Switching | |
| Contact switching type | 1 changeover contact |
| Type of switch contact | Double contact |
| Contact material | AgPd60, hard gold-plated |
| Maximum switching voltage | 30 V AC |
| 36 V DC | |
| Limiting continuous current | 0.5 A |
| Maximum inrush current | 0.2 A |
| Interrupting rating (ohmic load) max. | 5 W (at 24 V DC) |
| Switching: when the gold layer is destroyed | |
| Note | the following values are applicable if a gold layer is destroyed |
| Maximum switching voltage | 125 V AC |
| 150 V DC | |
| Limiting continuous current | 2 A |
| Maximum inrush current | 2 A |
| Interrupting rating (ohmic load) max. | 29 W (at 24 V DC) |
| 29 W (at 48 V DC) | |
| 29 W (at 60 V DC) | |
| Width | 20.8 mm |
| Height | 33 mm |
| Depth | 66.5 mm |
| Color | green (RAL 6021) |
| Ambient conditions | |
| Ambient temperature (operation) | -20 °C ... 50 °C |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Standards/regulations | DIN VDE 0110b, Gr. C for 250 V DC |
| IEC 60255/DIN VDE 0435 (in relevant parts) | |
| DIN EN 50178/VDE 0160 (in relevant parts) | |
| EN 60730/DIN VDE 0631 | |
| DIN VDE 0160 (in relevant parts) |
| Mounting type | Plug-in mounting |