View larger
ST-REL2-KG230AC/1AU 2826486 PHOENIX CONTACT Relay connectors
ST-REL2-KG230AC/1AU
2826486
PHOENIX CONTACT
1 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Safeguard control circuits using the Phoenix Contact ST-REL2-KG230AC/1AU relay connector. These components serve as standard switching interfaces in automation networks, routing logical commands from PLCs to heavy-duty actuators while maintaining circuit isolation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Relay Module
- Operating mode: 100% operating factor
- Mechanical service life: approx. 2x 10 7 cycles
- Data management status Date of last data management: 02.05.2024
- Article revision: 12
- Maximum power dissipation for nominal condition: 1.15 W
- Test voltage (Winding/contact): 2.5 kV AC (50 Hz, 1 min., winding/contact)
- Coil side Nominal input voltage U N: 230 V AC
- Input voltage range: 184 V AC ... 243.8 V AC (20 °C)
- Mains frequency: 50/60 Hz
- Drive and function: monostable
- Drive (polarity): polarized
- Typical input current at U N: 5 mA
- Typical response time: 4 ms ... 10 ms (with AC)
- Typical release time range: 4 ms ... 10 ms (with AC)
- Protective circuit: Bridge rectifier
More info
▲| Product type | Relay Module |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 2x 107cycles |
| Data management status | |
| Date of last data management | 02.05.2024 |
| Article revision | 12 |
| Maximum power dissipation for nominal condition | 1.15 W |
| Test voltage (Winding/contact) | 2.5 kV AC (50 Hz, 1 min., winding/contact) |
| Coil side | |
| Nominal input voltage UN | 230 V AC |
| Input voltage range | 184 V AC ... 243.8 V AC (20 °C) |
| Mains frequency | 50/60 Hz |
| Drive and function | monostable |
| Drive (polarity) | polarized |
| Typical input current at UN | 5 mA |
| Typical response time | 4 ms ... 10 ms (with AC) |
| Typical release time range | 4 ms ... 10 ms (with AC) |
| Protective circuit | Bridge rectifier; Bridge rectifier |
| Surge protection; Varistor | |
| Operating voltage display | yes |
| Switching | |
| Contact switching type | 1 N/O contact |
| Type of switch contact | Double contact |
| Contact material | AgPd60, hard gold-plated |
| Maximum switching voltage | 30 V AC |
| 36 V DC | |
| Limiting continuous current | 0.5 A |
| Maximum inrush current | 0.2 A |
| Interrupting rating (ohmic load) max. | 5 W (at 24 V DC) |
| Switching: when the gold layer is destroyed | |
| Note | the following values are applicable if a gold layer is destroyed |
| Maximum switching voltage | 125 V AC |
| 150 V DC | |
| Limiting continuous current | 2 A |
| Maximum inrush current | 2 A |
| Interrupting rating (ohmic load) max. | 29 W (at 24 V DC) |
| 29 W (at 48 V DC) | |
| 29 W (at 60 V DC) | |
| 60 VA (for 250 V AC) | |
| Width | 14.6 mm |
| Height | 33 mm |
| Depth | 66.5 mm |
| Color | green (RAL 6021) |
| Ambient conditions | |
| Ambient temperature (operation) | -20 °C ... 50 °C |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Standards/regulations | DIN VDE 0110b, Gr. C for 250 V DC |
| IEC 60255/DIN VDE 0435 (in relevant parts) | |
| DIN EN 50178/VDE 0160 (in relevant parts) | |
| EN 60730/DIN VDE 0631 | |
| DIN VDE 0160 (in relevant parts) |
| Mounting type | Plug-in mounting |