View larger
ST-REL2-KG 24/1AU 2823722 PHOENIX CONTACT Relay connectors
ST-REL2-KG 24/1AU
2823722
PHOENIX CONTACT
1 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Relay modules like the ST-REL2-KG 24/1AU 2823722 PHOENIX CONTACT Relay connectors function as critical interface links inside electrical control panels, isolating delicate electronics from high-power loads. They are commonly employed across industrial automation systems to route signals and protect downstream hardware from electrical faults.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Relay Module
- Operating mode: 100% operating factor
- Mechanical service life: approx. 2x 10 7 cycles
- Data management status Date of last data management: 02.05.2024
- Article revision: 07
- Maximum power dissipation for nominal condition: 0.5 W
- Test voltage (Winding/contact): 2.5 kV AC (50 Hz, 1 min., winding/contact)
- Coil side Nominal input voltage U N: 24 V AC/DC
- Input voltage range: 19.2 V AC/DC ... 26.4 V AC/DC (20 °C)
- Drive and function: monostable
- Drive (polarity): polarized
- Typical input current at U N: 21 mA
- Typical response time: 7 ms (with DC)
- Typical release time: 11 ms (with DC)
- Protective circuit: Bridge rectifier, varistor
- Operating voltage display: yes
More info
▲| Product type | Relay Module |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 2x 107cycles |
| Data management status | |
| Date of last data management | 02.05.2024 |
| Article revision | 07 |
| Maximum power dissipation for nominal condition | 0.5 W |
| Test voltage (Winding/contact) | 2.5 kV AC (50 Hz, 1 min., winding/contact) |
| Coil side | |
| Nominal input voltage UN | 24 V AC/DC |
| Input voltage range | 19.2 V AC/DC ... 26.4 V AC/DC (20 °C) |
| Drive and function | monostable |
| Drive (polarity) | polarized |
| Typical input current at UN | 21 mA |
| Typical response time | 7 ms (with DC) |
| Typical release time | 11 ms (with DC) |
| Protective circuit | Bridge rectifier, varistor |
| Operating voltage display | yes |
| Switching | |
| Contact switching type | 1 N/O contact |
| Type of switch contact | Double contact |
| Contact material | AgPd60, hard gold-plated |
| Maximum switching voltage | 30 V AC |
| 36 V DC | |
| Limiting continuous current | 0.5 A |
| Maximum inrush current | 0.2 A |
| Interrupting rating (ohmic load) max. | 5 W (at 24 V DC) |
| Switching: when the gold layer is destroyed | |
| Note | the following values are applicable if a gold layer is destroyed |
| Maximum switching voltage | 125 V AC |
| 150 V DC | |
| Limiting continuous current | 2 A |
| Maximum inrush current | 2 A |
| Interrupting rating (ohmic load) max. | 29 W (at 24 V DC) |
| 29 W (at 48 V DC) | |
| 29 W (at 60 V DC) | |
| 60 VA (for 250 V AC) | |
| Width | 14.6 mm |
| Height | 33 mm |
| Depth | 66.5 mm |
| Color | green (RAL 6021) |
| Ambient conditions | |
| Ambient temperature (operation) | -20 °C ... 50 °C |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Standards/regulations | DIN VDE 0110b, Gr. C for 250 V DC |
| IEC 60255/DIN VDE 0435 (in relevant parts) | |
| DIN EN 50178/VDE 0160 (in relevant parts) | |
| EN 60730/DIN VDE 0631 | |
| DIN VDE 0160 (in relevant parts) |
| Mounting type | Plug-in mounting |