View larger
SPT 2,5/ 4-V-5,0 MC BU/GN 3RZ 1008524 PHOENIX CONTACT Terminal for printed circuit board, rated voltage: 400..
SPT 2,5/ 4-V-5,0 MC BU/GN 3RZ
1008524
PHOENIX CONTACT
60 Pcs.
Connectors > Printed circuit board terminal
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for high-performance connectivity, the Phoenix Contact SPT 2,5/ 4-V-5,0 MC BU/GN 3RZ serves as a reliable PCB terminal block for routing power and signals in industrial hardware. Terminal blocks of this category ensure stable electrical paths between external wiring harnesses and sensitive internal circuit components.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: PCB terminal block
- Product Family: SPT 2.5/.. -V
- Product Line: COMBICON Terminals M
- Number of poles: 4
- Step: 5 mm
- Number of connections: 4
- Number of rows: 1
- Number of potentials: 4
- Pin Layout: Linear Pinning
- Number of Welding Pins per Potential: 2
- Data maintenance status Article review: 00
- Rated Current I N: 24 A
- Rated voltage U N: 400 V
- Sizing voltage (III/3): 250 V
- Sizing impulse voltage (III/3): 4 kV
- Sizing voltage (III/2): 400 V
More info
▲| Product Type | PCB terminal block |
| Product Family | SPT 2.5/.. -V |
| Product Line | COMBICON Terminals M |
| Number of poles | 4 |
| Step | 5 mm |
| Number of connections | 4 |
| Number of rows | 1 |
| Number of potentials | 4 |
| Pin Layout | Linear Pinning |
| Number of Welding Pins per Potential | 2 |
| Data maintenance status | |
| Article review | 00 |
| Rated Current IN | 24 A |
| Rated voltage UN | 400 V |
| Sizing voltage (III/3) | 250 V |
| Sizing impulse voltage (III/3) | 4 kV |
| Sizing voltage (III/2) | 400 V |
| Sizing Impulse Voltage (III/2) | 4 kV |
| Sizing voltage (II/2) | 630 V |
| Sizing Impulse Voltage (II/2) | 4 kV |
| Connection technology | |
| Nominal cross-section | 2.5 mm² |
| Conductor connection | |
| Link | Push-in spring connection |
| Rigid conductor cross-section | 0.2 mm² ... 4 mm² |
| Flexible conductor cross-section | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Flexible conductor cross-section with cable lug without plastic collar | 0.25 mm² ... 2.5 mm² |
| Flexible conductor cross-section with mounted lug and plastic collar | 0.25 mm² ... 2.5 mm² |
| Length of the section to be stripped | 10 mm |
| Indications for ferrules without isolation collar | |
| Recommended crimping tool | 1212034 CRIMPFOX 6 |
| cable lug without insulating collar, in accordance with DIN 46228-1 | Cross-section: 0.25 mm²; Length: 7 mm |
| Cross-section: 0.34 mm²; Length: 7 mm | |
| Cross-section: 0.5 mm²; Length: 8 mm | |
| Cross-section: 0.75 mm²; Length: 8 mm | |
| Cross-section: 1 mm²; Length: 8 mm | |
| Cross-section: 1.5 mm²; Length: 8 mm | |
| Cross-section: 2.5 mm²; Length: 8 mm | |
| Indications for ferrules with isolation collar | |
| Recommended crimping tool | 1212034 CRIMPFOX 6 |
| cable lug with insulating collar, in accordance with DIN 46228-4 | Cross-section: 0.25 mm²; Length: 8 mm |
| Cross-section: 0.34 mm²; Length: 8 mm | |
| Cross-section: 0.5 mm²; Length: 8 mm 10 mm | |
| Cross-section: 0.75 mm²; Length: 8 mm 10 mm | |
| Cross-section: 1 mm²; Length: 8 mm 10 mm | |
| Cross-section: 1.5 mm²; Length: 8 mm 10 mm | |
| Cross-section: 2.5 mm²; Length: 10 mm | |
| Mounting type | Wave Soldering |
| Pin Layout | Linear Pinning |
| Material information - contacts | |
| note | Complies with WEEE/RoHS, no thread-like materials according to IEC 60068-2-82/JEDEC JESD 201 |
| Contact Material | Cu Alloy |
| Surface Finish | Galvanic tin plating |
| Metal Surface, Connection Point (Surface Layer) | Tin (4 - 8 μm Sn) |
| Metal Surface Welding Area (Surface Layer) | Tin (4 - 8 μm Sn) |
| Material information - case | |
| Color (Case) | multicolor () |
| Insulation material | PA |
| Insulation Material Group | The |
| CTI according to IEC 60112 | 600 |
| Combustibility class according to UL 94 | V0 |
| Flammability index of GWFI filament according to EN 60695-2-12 | 850 |
| GWIT filament ignition temperature according to EN 60695-2-13 | 775 |
| Brinell hardness test temperature according to EN 60695-10-2 | 125 °C |
| Step | 5 mm |
| Width [w] | 36.4 mm |
| Height [h] | 16.9 mm |
| Length [l] | 13.5 mm |
| Installation Height | 14.4 mm |
| Weld Shank Length [P] | 2.5 mm |
| Printed circuit board design | |
| Shank Distance | 8.2 mm |
| Bore diameter | 1.2 mm |
| Conductor Integrity and Stability Test | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Result | Test passed |
| Tensile test | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Conductor cross-section/conductor type/tensile force nominal value/actual value | 0.2 mm² / rigid / > 10 N |
| 0.2 mm² / flexible / > 10 N | |
| 4 mm² / rigid / > 60 N | |
| 2.5 mm² / flexible / > 50 N | |
| Ambient Temperature Test | |
| Test Specification | DIN EN IEC 60947-7-4 (VDE 0611-7-4):2019-10 |
| Heating verification requirement | The sum of the ambient temperature and the heating of the PCB terminal should not exceed the upper limit of the temperature. |
| Short-term current resistance | |
| Test Specification | DIN EN IEC 60947-7-4 (VDE 0611-7-4):2019-10 |
| Insulation Resistance | |
| Test Specification | DIN EN 60512-3-1:2003-01 |
| Insulation Resistance Between Contiguous Poles | > 5 MΩ |
| Air and Surface Clearance Distances 1. Insulation coordination | |
| Application | without lattice fitting piece |
| Test Specification | DIN EN IEC 60947-7-4 (VDE 0611-7-4):2019-10 |
| Insulation Material Group | The |
| Resistance to surface currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Rated insulation voltage (III/3) | 250 V |
| Rated impulse voltage (III/3) | 4 kV |
| Minimum clearance value - inhomogeneous range (III/3) | 3 mm |
| Minimum creepage value (III/3) | 3.2 mm |
| Rated Isolation Voltage (III/2) | 400 V |
| Rated impulse voltage (III/2) | 4 kV |
| Minimum creepage value - inhomogeneous range (III/2) | 3 mm |
| Minimum creepage value (III/2) | 3 mm |
| Rated Isolation Voltage (II/2) | 630 V |
| Rated Impulse Voltage (II/2) | 4 kV |
| Minimum creepage value - inhomogeneous range (II/2) | 3 mm |
| Minimum creepage value (II/2) | 3.2 mm |
| Air and Surface Clearance Distances 2. Insulation coordination | |
| Application | with RZ-SPT 2.5-2.5 |
| Test Specification | DIN EN IEC 60947-7-4 (VDE 0611-7-4):2019-10 |
| Insulation Material Group | The |
| Resistance to surface currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Rated insulation voltage (III/3) | 400 V |
| Rated impulse voltage (III/3) | 6 kV |
| Minimum clearance value - inhomogeneous range (III/3) | 5.5 mm |
| Minimum creepage value (III/3) | 5.5 mm |
| Rated Isolation Voltage (III/2) | 630 V |
| Rated impulse voltage (III/2) | 6 kV |
| Minimum creepage value - inhomogeneous range (III/2) | 5.5 mm |
| Minimum creepage value (III/2) | 5.5 mm |
| Rated Isolation Voltage (II/2) | 1000 V |
| Rated Impulse Voltage (II/2) | 6 kV |
| Minimum creepage value - inhomogeneous range (II/2) | 5.5 mm |
| Minimum creepage value (II/2) | 5.5 mm |
| Air and Surface Clearance Distances 3. Insulation coordination | |
| Application | with RZ-SPT 2.5-5.0 |
| Test Specification | DIN EN IEC 60947-7-4 (VDE 0611-7-4):2019-10 |
| Insulation Material Group | The |
| Resistance to surface currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Rated insulation voltage (III/3) | 630 V |
| Rated impulse voltage (III/3) | 8 kV |
| Minimum clearance value - inhomogeneous range (III/3) | 8 mm |
| Minimum creepage value (III/3) | 8 mm |
| Rated Isolation Voltage (III/2) | 800 V |
| Rated impulse voltage (III/2) | 8 kV |
| Minimum creepage value - inhomogeneous range (III/2) | 8 mm |
| Minimum creepage value (III/2) | 8 mm |
| Rated Isolation Voltage (II/2) | 1000 V |
| Rated Impulse Voltage (II/2) | 8 kV |
| Minimum creepage value - inhomogeneous range (II/2) | 8 mm |
| Minimum creepage value (II/2) | 8 mm |
| Vibration test | |
| Test Specification | DIN EN 60068-2-6 (VDE 0468-2-6):2008-10 |
| Frequency | 10 - 150 - 10 Hz |
| Sweep Speed | 1 octave/min |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Acceleration | 50 m/s² (60.1 Hz ... 150 Hz) |
| Test duration per axle | 2.5 h |
| Test Directions | X, Y, and Z axis |
| Glow Wire Test | |
| Test Specification | DIN EN 60695-2-10 (VDE 0471-2-10):2014-04 |
| Temperature | 850 °C |
| Duration of application | 5 s |
| Aging | |
| Test Specification | DIN EN IEC 60947-7-4 (VDE 0611-7-4):2019-10 |
| Environmental conditions | |
| Ambient temperature (operating) | -40 °C ... 105 °C (Depending on current flow curve/derating curve) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Relative humidity (transport and storage) | 30 % ... 70 % |
| Ambient temperature (mounting) | -5 °C ... 100 °C |
| Packaging | Packed in carton |