SPT 2,5/10-V-5,0 GY BD:33-4-Q 1846738 PHOENIX CONTACT Terminal for printed circuit board, nominal current: 2..
SPT 2,5/10-V-5,0 GY BD:33-4-Q
1846738
PHOENIX CONTACT
1000 Pcs.
Connectors > Printed circuit board terminal
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact SPT 2,5/10-V-5,0 GY BD:33-4-Q terminal for printed circuit board serves as a reliable interface component that mounts directly onto electronics substrates to receive external cabling. Terminal blocks of this classification streamline internal device wiring and signal distribution.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: Printed Circuit Board Terminal
- Product Family: SPT 2.5/.. -V
- Product Line: COMBICON Terminals M
- Number of poles: 10
- Step: 5 mm
- Number of connections: 10
- Number of rows: 1
- Number of potentials: 10
- Pin Design: Linear Pin Arrangement
- Number of Solder Pins Per Potential: 2
- Data Maintenance Status Article Review: 00
- Nominal Current I N: 24 A
- Nominal voltage U N: 400 V
- Sizing voltage (III/3): 250 V
- Dimensioning transient voltage (III/3): 4 kV
- Dimensioning voltage (III/2): 400 V
More info
▲| Product Type | Printed Circuit Board Terminal |
| Product Family | SPT 2.5/.. -V |
| Product Line | COMBICON Terminals M |
| Number of poles | 10 |
| Step | 5 mm |
| Number of connections | 10 |
| Number of rows | 1 |
| Number of potentials | 10 |
| Pin Design | Linear Pin Arrangement |
| Number of Solder Pins Per Potential | 2 |
| Data Maintenance Status | |
| Article Review | 00 |
| Nominal Current IN | 24 A |
| Nominal voltage UN | 400 V |
| Sizing voltage (III/3) | 250 V |
| Dimensioning transient voltage (III/3) | 4 kV |
| Dimensioning voltage (III/2) | 400 V |
| Dimensioning Transient Voltage (III/2) | 4 kV |
| Nominal voltage (II/2) | 630 V |
| Dimensioning transient voltage (II/2) | 4 kV |
| Connection technology | |
| Nominal Section | 2.5 mm² |
| Connecting Conductors | |
| Connection type | Push-in spring connection |
| Rigid conductor section | 0.2 mm² ... 4 mm² |
| Flexible conductor section | 0.2 mm² ... 2.5 mm² |
| AWG Conductor Section | 24 ... 12 |
| Flexible conductor section with toe cap, without plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Flexible conductor section with toe cap, with plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Peel Length | 10 mm |
| Facts about toe caps without an insulated collar | |
| Recommended crimp pliers | 1212034 CRIMPFOX 6 |
| toe caps without insulating collar, according to DIN 46228-1 | Cross-section: 0.25 mm²; Length: 7 mm |
| Cross-section: 0.34 mm²; Length: 7 mm | |
| Cross-section: 0.5 mm²; Length: 8 mm | |
| Section: 0.75 mm²; Length: 8 mm | |
| Section: 1 mm²; Length: 8 mm | |
| Section: 1.5 mm²; Length: 8 mm | |
| Section: 2.5 mm²; Length: 8 mm | |
| Facts about Insulated Collar Toe Caps | |
| Recommended crimp pliers | 1212034 CRIMPFOX 6 |
| toe caps with insulated collar, according to DIN 46228-4 | Cross-section: 0.25 mm²; Length: 8 mm |
| Cross-section: 0.34 mm²; Length: 8 mm | |
| Cross-section: 0.5 mm²; Length: 8 mm ... 10 mm | |
| Cross-section: 0.75 mm²; Length: 8 mm ... 10 mm | |
| Cross-section: 1 mm²; Length: 8 mm ... 10 mm | |
| Cross-section: 1.5 mm²; Length: 8 mm ... 10 mm | |
| Cross-section: 2.5 mm²; Length: 10 mm | |
| Type of mounting | Wave soldering |
| Pin Design | Linear Pin Arrangement |
| Material data - contact | |
| Observation | WEEE/RoHS compliant, filament-free according to IEC 60068-2-82/JEDEC JESD 201 |
| Contact material | Cu Alloy |
| Surface Characteristics | Galvanically tinned |
| Metal surface of the terminal point (top layer) | Tin (4 - 8 μm Sn) |
| Metal surface weld area (top layer) | Tin (4 - 8 μm Sn) |
| Material data - housing | |
| Color (Housing) | Grey (7042) |
| Insulating material | PA |
| Insulating material group | I |
| CTI according to IEC 60112 | 600 |
| Flammability class according to UL 94 | V0 |
| Flammability number of GWFI incandescent filaments according to EN 60695-2-12 | 850 |
| Ignition temperature of incandescent filaments GWIT according to EN 60695-2-13 | 775 |
| Ball hardness test temperature according to EN 60695-10-2 | 125 °C |
| Step | 5 mm |
| Width [w] | 51.4 mm |
| Height [h] | 16.9 mm |
| Length [l] | 13.5 mm |
| Overall Height | 14.4 mm |
| Weld Pin Length [P] | 2.5 mm |
| Printed circuit board design | |
| Spacing between rods | 8.2 mm |
| Hole diameter | 1.2 mm |
| Checking for damage to conductors and loosening | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Result | Approved Test |
| Tensile Test | |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Conductor Section/Conductor Type/Tensile Force Nominal Value/Actual Value | 0.2 mm² / rigid / > 10 N |
| 0.2 mm² / flexible / > 10 N | |
| 4 mm² / rigid / > 60 N | |
| 2.5 mm² / flexible / > 50 N | |
| Heating Verification | |
| Test Specification | DIN EN IEC 60947-7-4 (VDE 0611-7-4):2019-10 |
| Heating test requirement | The sum of the ambient temperature and the heating of the PCB connection terminal cannot exceed the upper limit temperature. |
| Short-term permissible current | |
| Test Specification | DIN EN IEC 60947-7-4 (VDE 0611-7-4):2019-10 |
| Insulation resistance | |
| Test Specification | DIN EN 60512-3-1:2003-01 |
| Insulation Resistance Adjacent Poles | > 5 MΩ |
| Creepage Lines & Air Isolation Distances 1. Coordination of insulations | |
| application | without intermediate step piece |
| Test Specification | DIN EN IEC 60947-7-4 (VDE 0611-7-4):2019-10 |
| Insulating material group | I |
| Resistance to leakage currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Sizing Insulation Voltage (III/3) | 250 V |
| Nominal transient voltage (III/3) | 4 kV |
| minimum value of air insulation distance - non-homogeneous field (III/3) | 3 mm |
| Minimum creepage line value (III/3) | 3.2 mm |
| Sizing Insulation Voltage (III/2) | 400 V |
| Nominal transient voltage (III/2) | 4 kV |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (III/2) | 3 mm |
| Minimum creepage line value (III/2) | 3 mm |
| Sizing Insulation Voltage (II/2) | 630 V |
| Nominal transient voltage (II/2) | 4 kV |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (II/2) | 3 mm |
| Minimum creepage line value (II/2) | 3.2 mm |
| Creepage Lines & Air Isolation Distances 2. Coordination of insulations | |
| application | with RZ-SPT 2.5-2.5 |
| Test Specification | DIN EN IEC 60947-7-4 (VDE 0611-7-4):2019-10 |
| Insulating material group | I |
| Resistance to leakage currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Sizing Insulation Voltage (III/3) | 400 V |
| Nominal transient voltage (III/3) | 6 kV |
| minimum value of air insulation distance - non-homogeneous field (III/3) | 5.5 mm |
| Minimum creepage line value (III/3) | 5.5 mm |
| Sizing Insulation Voltage (III/2) | 630 V |
| Nominal transient voltage (III/2) | 6 kV |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (III/2) | 5.5 mm |
| Minimum creepage line value (III/2) | 5.5 mm |
| Sizing Insulation Voltage (II/2) | 1000 V |
| Nominal transient voltage (II/2) | 6 kV |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (II/2) | 5.5 mm |
| Minimum creepage line value (II/2) | 5.5 mm |
| Leakage Lines & Air Isolation Distances 3. Isolation coordination | |
| application | with RZ-SPT 2.5-5.0 |
| Test Specification | DIN EN IEC 60947-7-4 (VDE 0611-7-4):2019-10 |
| Insulating material group | I |
| Resistance to leakage currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Sizing Insulation Voltage (III/3) | 630 V |
| Nominal transient voltage (III/3) | 8 kV |
| minimum value of air insulation distance - non-homogeneous field (III/3) | 8 mm |
| Minimum creepage line value (III/3) | 8 mm |
| Sizing Insulation Voltage (III/2) | 800 V |
| Nominal transient voltage (III/2) | 8 kV |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (III/2) | 8 mm |
| Minimum creepage line value (III/2) | 8 mm |
| Sizing Insulation Voltage (II/2) | 1000 V |
| Nominal transient voltage (II/2) | 8 kV |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (II/2) | 8 mm |
| Minimum creepage line value (II/2) | 8 mm |
| Vibration test | |
| Test Specification | DIN EN 60068-2-6 (VDE 0468-2-6):2008-10 |
| frequency | 10 - 150 - 10 Hz |
| Sweep speed | 1 octave/min |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Acceleration | 50 m/s² (60.1 Hz ... 150 Hz) |
| Test duration per axis | 2.5 h |
| Test Directions | X, Y, and Z axes |
| Essay filam. incandescent | |
| Test Specification | DIN EN 60695-2-10 (VDE 0471-2-10):2014-04 |
| Temperature | 850 °C |
| Performance Time | 5 s |
| Aging | |
| Test Specification | DIN EN IEC 60947-7-4 (VDE 0611-7-4):2019-10 |
| Environmental conditions | |
| Ambient Temperature (Service) | -40 °C ... 105 °C (Depending on the current carrying capacity/derating curve) |
| Ambient Temperature (Storage/Transport) | -40 °C ... 70 °C |
| Relative humidity of the air (storage/transport) | 30 % ... 70 % |
| Ambient Temperature (Mounting) | -5 °C ... 100 °C |
| Type of packaging | Boxed Packaging |