View larger
AXL F SSI1 AO1 1H 2688433 PHOENIX CONTACT Special function module
AXL F SSI1 AO1 1H
2688433
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - function-/technology module
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact AXL F SSI1 AO1 1H is a special function module built for advanced data acquisition and signal processing within Axioline industrial networks. Hybrid function modules handle specialized sensor interfaces and analog tasks simultaneously to streamline system architectures. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Number of functions (EF003244): 2
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
- Number of HW-interfaces serial TTY (EF003024): 0
- Number of HW-interfaces parallel (EF003026): 0
- Number of HW-interfaces wireless (EF006933): 0
- Number of HW-interfaces USB (EF003025): 0
- Number of HW-interfaces other (EF003027): 0
- With optical interface (EF003028): No
- Supporting protocol for EtherCAT (EF017564): No
- Supporting protocol for TCP/IP (EF003050): No
- Supporting protocol for PROFIBUS (EF003052): Yes
More info
▲Key Commercial Data
| Orderkey | 2688433 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 122 (C-6-2017) |
| GTIN | 4046356644952 |
| Weight per Piece (excluding packing) | 135.000 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
Dimensions
| Dimensional drawing | |
|---|---|
| Width | 35 mm |
| Height | 126.1 mm |
| Depth | 54 mm |
| Note on dimensions | The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP20 |
Connection data
| Designation | Axioline F connector |
|---|---|
| Connection method | Push-in connection |
| Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
General
| Mounting type | DIN rail |
|---|---|
| Net weight | 135 g |
| Note on weight specifications | with connectors and bus base module |
Interfaces
| Designation | Axioline F local bus |
|---|---|
| No. of channels | 2 |
| Connection method | Bus base module |
| Transmission speed | 100 Mbps |
Axioline potentials
| Designation | Axioline F local bus supply (UBus) |
|---|---|
| Supply voltage | 5 V DC (via bus base module) |
| Current consumption | max. 140 mA |
| Power consumption | max. 0.7 W |
| Designation | Supply voltage input UI |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC including all tolerances, including ripple |
| Current consumption | max. 60 mA (Supply of the SSI interface and the analog output (20 mA), without sensor supply) |
| Power consumption | max. 1.4 W (Supply of the SSI interface and the analog output (20 mA), without sensor supply) |
| Type of protection | Surge protection of the supply voltage |
| Polarity reversal protection of the supply voltage | |
| Transient protection |
Encoder inputs
| Input name | SSI interface |
|---|---|
| Description of the input | RS-422 interface according to SSI specification |
| Number of inputs | 1 |
| Connection method | Push-in connection |
| Encoder signals | Single-turn and multi-turn encoder, length measuring sticks |
| Input frequency | to 2 MHz (Can be parameterized: 67.5 kHz, 125 kHz (default), 250 kHz, 500 kHz, 1 MHz, 2 MHz) |
| Parity | Even, odd or no parity |
| Transmission frequency | 2 MHz |
| Adjustable resolution | 8 ... 56 bit |
| Encoder supply voltage | 24 V DC (UI- 0.5 V) |
Encoder data
| Nominal output voltage | 24 V DC (UI- 0.5 V) |
|---|---|
| Voltage range | 19.5 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current carrying capacity | max. 500 mA |
| Type of protection | Surge protection |
| Short-circuit/overload protection | |
| Transient protection |
Analog outputs
| Number of outputs | 1 |
|---|---|
| Connection method | Push-in connection |
| Connection technology | 2-wire (shielded, twisted pair) |
| Output name | Analog outputs |
| D/A conversion time | 5 µs |
| D/A resolution | 16 bit |
| Type of protection | Surge protection |
| Short-circuit and overload protection | |
| Transient protection | |
| Protective circuit/component | Electronic (35 V, permanent) |
| Electronic | |
| Suppressor diode | |
| Data formats | IB IL, S7-compatible, standardized representation |
| Measured value representation | 16 bits |
| Representation of output values | 16 bits (15 bits + sign) |
| Current output signal | 0 mA ... 20 mA |
| 4 mA ... 20 mA | |
| -20 mA ... 20 mA | |
| Load/output load current output | max. 500 Ω |
| Voltage output signal | 0 V ... 5 V |
| -5 V ... 5 V | |
| 0 V ... 10 V | |
| -10 V ... 10 V | |
| Load/output load voltage output | > 2 kΩ |
| Precision | typ. 0.1 % (of output range final value) |
| Permissible cable length | max. 250 m |
Electrical isolation
| Test section | Logic 500 V AC 50 Hz 1 min. |
|---|---|
| SSI I/O (24 V supply) 500 V AC 50 Hz 1 min. | |
| Functional earth ground 500 V AC 50 Hz 1 min. | |
| Analog I/O 500 V AC 50 Hz 1 min. |
Standards and Regulations
| Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
|---|---|
| Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g | |
| Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
| Protection class | III, IEC 61140, EN 61140, VDE 0140-1 |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
| No hazardous substances above threshold values |