View larger
EMG 17-OV- 24DC/240AC/3 2954235 PHOENIX CONTACT Solid-state relay module
EMG 17-OV-24DC/240AC/3
2954235
PHOENIX CONTACT
1 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Housing power-switching semiconductors in a modular profile, the EMG 17-OV- 24DC/240AC/3 2954235 PHOENIX CONTACT Solid-state relay module isolates control circuits from higher-voltage alternating current loads. Engineers integrate these modules into switchgear assemblies to handle frequent switching cycles without mechanical degradation. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Input voltage (EF003840): 19.2 V
- Type of voltage (input voltage) (EF003033): DC
- Output voltage (EF003933): 48 V
- Type of output voltage (EF008222): AC
- Rated operation current Ie (EF001443): 3 A
- Type of digital output (EF003601): Electronic
- With LED indication (EF005950): Yes
More info
▲Key Commercial Data
| Orderkey | 2954235 |
|---|---|
| Packing unit | 10 pc |
| Catalog page | Page 141 (IF-2011) |
| GTIN | 4017918084899 |
| Weight per Piece (excluding packing) | 81.360 g |
| Custom tariff number | 85364190 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Degree of protection | IP20 |
Input data
| Nominal input voltage UN | 24 V DC |
|---|---|
| Input voltage range in reference to UN | 0.8 ... 1.2 |
| Input voltage range | 19.2 V DC ... 28.8 V DC |
| Switching threshold "0" signal in reference to UN | ≤ 0.4 |
| Switching threshold "1" signal in reference to UN | ≥ 0.8 |
| Typical input current at UN | 3.6 mA |
| Typical response time | 10 ms |
| Typical turn-off time | 10 ms |
| Operating voltage display | Yellow LED |
| Type of protection | Reverse polarity protection |
| Surge protection | |
| Protective circuit/component | Polarity protection diode |
| Varistor | |
| Transmission frequency | 25 Hz |
Output data
| Output nominal voltage | 240 V AC |
|---|---|
| Output voltage range | 48 V AC ... 280 V AC (50 Hz ... 60 Hz) |
| Limiting continuous current | 3 A (see derating curve) |
| Min. load current | 50 mA |
| Leakage current | 4 mA (in off state) |
| Surge current | 160 A (t = 10 ms) |
| Max. load value | 128 A2s (I2x t where t = 10 ms) |
| Peak offstate voltage | 600 V (Periodic peak reverse voltage) |
| Voltage drop at max. limiting continuous current | ≤ 1 V |
| Output circuit | 2-wire, floating |
| Type of protection | RC element |
| Surge protection | |
| Protective circuit/component | RC element |
| Varistor |
Connection data, input side
| Connection name | Input side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
Connection data, output side
| Connection name | Output side |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
General
| Test voltage input/output | 3.5 kV AC |
|---|---|
| 3.5 kV AC | |
| Mounting position | horizontal |
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Flammability rating according to UL 94 | V0 |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| Degree of pollution | 2 |
| Overvoltage category | III |
Standards and Regulations
| Standards/regulations | IEC 60664 |
|---|---|
| EN 50178 | |
| Insulation | Basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |