View larger
CB S-BE 2905067 PHOENIX CONTACT Base element
CB S-BE
2905067
PHOENIX CONTACT
30 Pcs.
Automation > Accessories/spare parts for electrical fuses/fuse holders
Over Current Protection
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact CB S-BE base element provides a stable mechanical foundation and electrical receptacle for modular circuit protection components in control cabinet layouts. Base elements streamline wiring architectures by allowing protective modules to be easily plugged into a standardized DIN rail interface. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Base element
- Product family: CB BE
- Type: Base element, PCB mounting
- General Rated insulation voltage U i: 80 V DC
- Rated surge voltage: 2.5 kV
- Insertion/withdrawal cycles: 50
- Main circuit Rated voltage: 80 V DC
- Rated current I N: 16 A
- Remote indication circuit Rated voltage: 80 V DC
- Rated current I N: 1 A
- Connection method: Solder connection
- Width: 12.3 mm
- Height: 34.8 mm
- Depth: 36.4 mm
- Color: gray (RAL 7042)
- Flammability rating according to UL 94: V0
More info
▲| Product type | Base element |
| Product family | CB BE |
| Type | Base element, PCB mounting |
| General | |
| Rated insulation voltage Ui | 80 V DC |
| 277 V AC | |
| Rated surge voltage | 2.5 kV |
| Insertion/withdrawal cycles | 50 |
| Main circuit | |
| Rated voltage | 80 V DC |
| 277 V AC | |
| Rated current IN | 16 A |
| Remote indication circuit | |
| Rated voltage | 80 V DC |
| 277 V AC | |
| Rated current IN | 1 A |
| Connection method | Solder connection |
| Dimensional drawing | |
| Width | 12.3 mm |
| Height | 34.8 mm |
| Depth | 36.4 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Housing material | PA 6.6 |
| Ambient conditions | |
| Degree of protection | IP30 (Plug-in area with plugged-in device) |
| IP00 (Connection area) | |
| Ambient temperature (operation) | -30 °C ... 60 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Humidity test | 240 h, 95 % RH, 40 °C |
| Standards/specifications | DIN EN 50155 |
| Standards/specifications | IEC 60068-2 |
| Mounting type | On PCB |