View larger
SOL-SC-2ST-0-DC-3MPPT-1001SE 1478915 PHOENIX CONTACT String box for photovoltaic installations up to 1000 V ..
SOL-SC-2ST-0-DC-3MPPT-1001SE
1478915
PHOENIX CONTACT
25 Pcs.
Automation > Photovoltaic DC Stringbox
Industry Solutions (IS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
SOL-SC-2ST-0-DC-3MPPT-1001SE 1478915 PHOENIX CONTACT String box for photovoltaic installations up to 1000 V enclosures organize and protect DC power feeds coming from solar panel arrays before they reach the inverter. These distribution assemblies typically house integrated surge protection and disconnecting elements to safeguard delicate power electronics from transient voltage spikes. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: String combiner box (SCB)
- Scope of delivery: SUNCLIX DC connector for connecting the SCB
- Insulation characteristics Protection class: II
- General MPP voltage U N: max. 1000 V DC
- Non-load voltage U OC: max. 1100 V DC
- Current per string I max: max. 20 A
- Total current MPP tracker: max. 40 A
- Surge protection EN type: T1
- IEC test classification: T1
- Protection level U p: ≤ 3.5 kV
- Total discharge current I total (10/350) µs: 5 kA
- Total discharge current I total (8/20) µs: 40 kA
- Short-circuit current rating I SCPV: 40 A
- DC Number of inputs: Strings: 2 (per MPP tracker)
- Number of supported MPP trackers: 3
- DC Number of outputs: MPP tracker: 3
More info
▲| Product type | String combiner box (SCB) |
| Scope of delivery | SUNCLIX DC connector for connecting the SCB |
| Insulation characteristics | |
| Protection class | II |
| General | |
| MPP voltage UN | max. 1000 V DC |
| Non-load voltage UOC | max. 1100 V DC |
| Current per string Imax | max. 20 A |
| Total current MPP tracker | max. 40 A |
| Surge protection | |
| EN type | T1 |
| IEC test classification | T1 |
| Protection level Up | ≤ 3.5 kV |
| Total discharge current Itotal(10/350) µs | 5 kA |
| Total discharge current Itotal(8/20) µs | 40 kA |
| Short-circuit current rating ISCPV | 40 A |
| DC | |
| Number of inputs: Strings | 2 (per MPP tracker) |
| Number of supported MPP trackers | 3 |
| DC | |
| Number of outputs: MPP tracker | 3 |
| Number of outputs: ± | 1 (per MPP tracker) |
| DC input | |
| Type of cable entry | SUNCLIX |
| Cable cross section | 2.5 mm² ... 6 mm² |
| Protective bonding and protective grounding conductor | |
| Type of cable entry | Cable gland |
| Cable cross section | 2x 16 mm² |
| External cable diameter | 6 mm ... 12 mm |
| DC output | |
| Type of cable entry | SUNCLIX |
| Cable cross section | 2.5 mm² ... 6 mm² |
| Housing | |
| Width | 361 mm |
| Height | 254 mm |
| Depth | 111 mm |
| Material Housing | Polycarbonate |
| Material Cover/door | Polycarbonate (transparent) |
| Ambient conditions | |
| Degree of protection | IP65 |
| Ambient temperature (operation) | -20 °C ... 55 °C |