View larger
SOL-SC-2ST-0-DC-2MPPT-1300FS 1137059 PHOENIX CONTACT String combiner box for photovoltaic systems up to 1000..
SOL-SC-2ST-0-DC-2MPPT-1300FS
1137059
PHOENIX CONTACT
1 Pcs.
Automation > Photovoltaic DC Stringbox
Industry Solutions (IS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact SOL-SC-2ST-0-DC-2MPPT-1300FS string combiner box for photovoltaic systems up to 1000.. functions as a centralized collection point for solar panel strings, merging multiple DC circuits into fewer main lines. Such junction boxes are essential in large-scale photovoltaic power plants for organizing field cabling while housing vital protective gear against lightning and electrical surges. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1137059
- Packing unit: 1
- GTIN: 4063151073619
- Custom tariff number: 85371098
- System voltage: 1000 V DC (U max )
- Number of string inputs: 2
- Current per string (max.): 20 A (I max )
- Number of outputs: 1
- Number of supported MPP trackers: 2
- Switching capacity: 50 A (1000 V)
- Rated operating current at DC-PV1: 20 A
- Surge protective device: T1 / T2
- Protection level U p: ≤ 3.5 kV
- Total discharge current I total (8/20) µs: 40 kA
- Total discharge current I total (10/350) µs: 5 kA
- Type of cable entry: Cable gland
More info
▲System parameter
| System voltage | 1000 V DC (Umax) |
|---|---|
| Number of string inputs | 2 |
| Current per string (max.) | 20 A (Imax) |
| Number of outputs | 1 |
| Number of supported MPP trackers | 2 |
| Switching capacity | 50 A (1000 V) |
| Rated operating current at DC-PV1 | 20 A |
Safety equipment
| Surge protective device | T1 / T2 |
|---|---|
| Protection level Up | ≤ 3.5 kV |
| Total discharge current Itotal(8/20) µs | 40 kA |
| Total discharge current Itotal(10/350) µs | 5 kA |
Cable entry
| Type of cable entry | Cable gland |
|---|---|
| Cable cross section string input | 2.5 mm² ... 6 mm² |
| Sealing area string input | 3 mm ... 6.5 mm |
| Cable cross section output | 2.5 mm² ... 6 mm² |
| Sealing area output | 3 mm ... 6.5 mm |
| Cable cross section grounding | 16 mm² (2x) |
| Sealing area grounding | 6 mm ... 12 mm (2x) |
| Cable cross section emergency stop | 3x 0.14 mm² ... 2.5 mm² (230 V AC) |
| 2x 0.14 mm² ... 2.5 mm² (Remote indication contact, potential-free, max. 24 V DC) | |
| Sealing area emergency stop | 6 mm ... 12 mm |
General data
| Material cover/door | Polyester fiberglass reinforced |
|---|---|
| Degree of protection | IP65 |
| Protection class | I |
Dimensions
| Outer dimensions: width, height, depth | 400 mm x 400 mm x 200 mm (Housing dimensions) |
|---|
Classifications
eCl@ss
| eCl@ss 10.0.1 | 27142422 |
|---|---|
| eCl@ss 5.1 | 27371890 |
| eCl@ss 7.0 | 27142422 |
| eCl@ss 8.0 | 27142422 |
| eCl@ss 9.0 | 27142422 |