View larger
SOL-SC-2ST-0-DC-10MPPT-1000EQS 1318524 PHOENIX CONTACT String box for photovoltaic systems up to 1000 V DC f..
SOL-SC-2ST-0-DC-10MPPT-1000EQS
1318524
PHOENIX CONTACT
1 Pcs.
Automation > Photovoltaic DC Stringbox
Industry Solutions (IS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Categorized as a string box for photovoltaic systems up to 1000 V DC, the Phoenix Contact SOL-SC-2ST-0-DC-10MPPT-1000EQS manages multiple circuit inputs from solar panels. These enclosures combine array outputs efficiently and provide safe, organized connection points with robust surge protection for large-scale alternative energy installations.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: String combiner box (SCB)
- Insulation characteristics Protection class: II
- MPP voltage U N: max. 1000 V DC
- Non-load voltage U OC: max. 1100 V DC
- Current per string I max: max. 20 A
- Surge protection EN type: T1 / T2
- Protection level U p: ≤ 3.5 kV
- Total discharge current I total (10/350) µs: 5 kA
- Total discharge current I total (8/20) µs: 40 kA
- Number of inputs: Strings: 2 (per MPP tracker)
- Number of supported MPP trackers: 10
- DC Number of outputs: MPP tracker: 10
- Number of outputs: ±: 2 (per MPP tracker)
- DC input Type of cable entry: Cable gland
- Connection method: Push-in connection
- Cable cross section: 4 mm² ... 6 mm²
More info
▲| Product type | String combiner box (SCB) |
| Insulation characteristics | |
| Protection class | II |
| MPP voltage UN | max. 1000 V DC |
| Non-load voltage UOC | max. 1100 V DC |
| Current per string Imax | max. 20 A |
| Surge protection | |
| EN type | T1 / T2 |
| Protection level Up | ≤ 3.5 kV |
| Total discharge current Itotal(10/350) µs | 5 kA |
| Total discharge current Itotal(8/20) µs | 40 kA |
| Number of inputs: Strings | 2 (per MPP tracker) |
| Number of supported MPP trackers | 10 |
| DC | |
| Number of outputs: MPP tracker | 10 |
| Number of outputs: ± | 2 (per MPP tracker) |
| DC input | |
| Type of cable entry | Cable gland |
| Connection method | Push-in connection |
| Cable cross section | 4 mm² ... 6 mm² |
| External cable diameter | 5 mm ... 7 mm |
| Protective bonding and protective grounding conductor | |
| Type of cable entry | Cable gland |
| Connection method | Push-in connection |
| Cable cross section | 2x 16 mm² |
| External cable diameter | 2x 6 mm ... 13 mm |
| DC output | |
| Type of cable entry | Cable gland |
| Connection method | Push-in connection |
| Cable cross section | 4 mm² ... 6 mm² |
| External cable diameter | 5 mm ... 7 mm |
| Housing | |
| Width | 600 mm |
| Height | 400 mm |
| Depth | 230 mm |
| Material Housing | Polyester fiberglass reinforced |
| Material Cover/door | Polyester fiberglass reinforced |
| Ambient conditions | |
| Degree of protection | IP65 |
| Ambient temperature (operation) | -20 °C ... 50 °C |
| Standard designation | Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies |
| Standards/specifications | EN 61439-2 |