View larger
SOL-SC-1ST-0-DC-2MPPT-2000SE 1105828 PHOENIX CONTACT String combiner box for photovoltaic systems up to 1000..
SOL-SC-1ST-0-DC-2MPPT-2000SE
1105828
PHOENIX CONTACT
1 Pcs.
Automation > Photovoltaic DC Stringbox
Industry Solutions (IS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact SOL-SC-1ST-0-DC-2MPPT-2000SE string combiner box for photovoltaic systems up to 1000.. functions as an integrated terminal enclosure that combines solar string inputs into main DC transmission lines. These units help streamline maintenance operations in large solar fields by centralizing surge suppression and disconnect points into a single protected housing. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1105828
- Packing unit: 1
- GTIN: 4055626990507
- System voltage: 1000 V DC (U max )
- Number of string inputs: 1 (per MPP tracker)
- Current per string (max.): 40 A (I max )
- Number of outputs: 1 (per MPP tracker)
- Number of supported MPP trackers: 2
- Surge protective device: T2
- Protection level U p: ≤ 3.7 kV
- Total discharge current I total (8/20) µs: 40 kA
- Type of cable entry: Cable gland
- Cable cross section string input: 2.5 mm² ... 6 mm²
- Sealing area string input: 3 mm ... 6.5 mm
- Cable cross section output: 2.5 mm² ... 6 mm²
- Sealing area output: 3 mm ... 6.5 mm
More info
▲System parameter
| System voltage | 1000 V DC (Umax) |
|---|---|
| Number of string inputs | 1 (per MPP tracker) |
| Current per string (max.) | 40 A (Imax) |
| Number of outputs | 1 (per MPP tracker) |
| Number of supported MPP trackers | 2 |
Safety equipment
| Surge protective device | T2 |
|---|---|
| Protection level Up | ≤ 3.7 kV |
| Total discharge current Itotal(8/20) µs | 40 kA |
Cable entry
| Type of cable entry | Cable gland |
|---|---|
| Cable cross section string input | 2.5 mm² ... 6 mm² |
| Sealing area string input | 3 mm ... 6.5 mm |
| Cable cross section output | 2.5 mm² ... 6 mm² |
| Sealing area output | 3 mm ... 6.5 mm |
| Cable cross section grounding | 16 mm² (2 x) |
| Sealing area grounding | 6 mm ... 12 mm (2x) |
General data
| Material cover/door | Polycarbonate (transparent) |
|---|---|
| Degree of protection | IP65 |
| Protection class | II |
Dimensions
| Outer dimensions: width, height, depth | 254 mm x 180 mm x 111 mm (Housing dimensions) |
|---|
Classifications
eCl@ss
| eCl@ss 10.0.1 | 27142422 |
|---|---|
| eCl@ss 5.1 | 27371890 |
| eCl@ss 7.0 | 27142422 |
| eCl@ss 8.0 | 27142422 |
| eCl@ss 9.0 | 27142422 |