A Phoenix Contact SOL-SC-1ST-0-DC-1MPPT-1300FS string combiner box for photovoltaic systems up to 1000.. aggregates solar string currents into an organized feed before the main power conversion stage. Such modular boxes streamline industrial PV wiring while shielding sensitive equipment from unexpected voltage spikes. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1137053
- Packing unit: 1
- GTIN: 4063151074302
- Custom tariff number: 85371098
- System voltage: 1000 V DC (U max )
- Number of string inputs: 1
- Current per string (max.): 40 A (I max )
- Number of outputs: 1
- Number of supported MPP trackers: 1
- Switching capacity: 50 A (1000 V)
- Rated operating current at DC-PV1: 40 A
- Surge protective device: T1 / T2
- Protection level U p: ≤ 3.5 kV
- Total discharge current I total (8/20) µs: 40 kA
- Total discharge current I total (10/350) µs: 5 kA
- Type of cable entry: Cable gland
More info
▲System parameter
| System voltage | 1000 V DC (Umax) |
|---|---|
| Number of string inputs | 1 |
| Current per string (max.) | 40 A (Imax) |
| Number of outputs | 1 |
| Number of supported MPP trackers | 1 |
| Switching capacity | 50 A (1000 V) |
| Rated operating current at DC-PV1 | 40 A |
Safety equipment
| Surge protective device | T1 / T2 |
|---|---|
| Protection level Up | ≤ 3.5 kV |
| Total discharge current Itotal(8/20) µs | 40 kA |
| Total discharge current Itotal(10/350) µs | 5 kA |
Cable entry
| Type of cable entry | Cable gland |
|---|---|
| Cable cross section string input | 2.5 mm² ... 6 mm² |
| Sealing area string input | 3 mm ... 6.5 mm |
| Cable cross section output | 2.5 mm² ... 6 mm² |
| Sealing area output | 3 mm ... 6.5 mm |
| Cable cross section grounding | 16 mm² (2x) |
| Sealing area grounding | 6 mm ... 12 mm (2x) |
| Cable cross section emergency stop | 3x 0.14 mm² ... 2.5 mm² (230 V AC) |
| 2x 0.14 mm² ... 2.5 mm² (Remote indication contact, potential-free, max. 24 V DC) | |
| Sealing area emergency stop | 6 mm ... 12 mm |
General data
| Material cover/door | Polyester fiberglass reinforced |
|---|---|
| Degree of protection | IP65 |
| Protection class | I |
Dimensions
| Outer dimensions: width, height, depth | 400 mm x 400 mm x 200 mm (Housing dimensions) |
|---|
Classifications
eCl@ss
| eCl@ss 10.0.1 | 27142422 |
|---|---|
| eCl@ss 5.1 | 27371890 |
| eCl@ss 7.0 | 27142422 |
| eCl@ss 8.0 | 27142422 |