View larger
SACCEC-M12FSB-5CON-M16/0,5-900 1529742 PHOENIX CONTACT Bus system flat-type plug
SACCEC-M12FSB-5CON-M16/0,5-900
1529742
PHOENIX CONTACT
1 Pcs.
Cables > Circular connector, mounting (with cable)
Field Device Connectors (FDC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing a reliable pass-through interface, the SACCEC-M12FSB-5CON-M16/0,5-900 1529742 PHOENIX CONTACT Bus system flat-type plug connects external fieldbus networks to internal machine electronics. These panel connectors ensure stable data and power distribution across complex industrial architectures. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Cable length (EF000536): 0.5 mm
- Mounting method (EF000003): Front mounting
- Ambient temperature (EF002386): 85 °C
- Operating temperature (EF002393): -25 °C
- Rated voltage (EF000228): 48 V
- With shield connection (EF002535): Yes
- Screw-in thread (EF012303): M12
- Min. number of insertion cycles (EF012212): 100
More info
▲Key Commercial Data
| Orderkey | 1529742 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 425 (C-2-2017) |
| GTIN | 4017918982652 |
| Weight per Piece (excluding packing) | 62.300 g |
| Custom tariff number | 85444290 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 85 °C (Plug / socket) |
|---|---|
| Degree of protection | IP67 |
General
| Rated current at 40°C | 4 A |
|---|---|
| Rated voltage | 60 V |
| Rated surge voltage | 1.5 kV |
| Number of positions | 5 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | B - inverse |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Status display | No |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Test voltage | 2500 V |
| Insertion/withdrawal cycles | > 100 |
| Torque | 3 Nm ... 4 Nm (Installation-side) |
Material
| Flammability rating according to UL 94 | V0 |
|---|---|
| Contact material | CuZn |
| Contact surface material | Ni/Au |
| Contact carrier material | PA 6.6 |
| Material, knurls | Nickel-plated brass |
| Sealing material | NBR |
Standards and Regulations
| Standard designation | M12 connector |
|---|---|
| Standards/regulations | IEC 61076-2-101 |
| Flammability rating according to UL 94 | V0 |
Cable
| Cable type | INTERBUS |
|---|---|
| Cable type (abbreviation) | 900 |
| Signal type/category | INTERBUS |
| Cable structure | 3 x 2 x 0.22 mm² |
| Conductor cross section | 3x 2x 0.22 mm² |
| AWG signal line | 24 |
| Conductor structure signal line | 32x 0.10 mm |
| Wire colors | Green-yellow, white-brown, gray-pink |
| Twisted pairs | 2 cores to the pair |
| Overall twist | 3 pairs to the core |
| Shielding | Braided copper wires |
| External sheath, color | may green RAL 6017 |
| External cable diameter D | 8 mm |
| Minimum bending radius, fixed installation | 7.5 x D |
| Minimum bending radius, flexible installation | 15 x D |
| Number of bending cycles | 5000000 |
| Bending radius | 120 mm |
| Traversing path | 10 m |
| Traversing rate | 1.6 m/s |
| Acceleration | 3.2 m/s² |
| Cable weight | 70 kg/km |
| Outer sheath, material | PUR |
| Material conductor insulation | PE |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 5 GΩ*km |
| Loop resistance | ≤ 159.80 Ω/km |
| Cable capacity | ≤ 60 nF/km (At 800 Hz) |
| Wave impedance | 120 Ω ±20 % (at 64 kHz) |
| 100 Ω ±15 % (with 1 MHz) | |
| Near end crosstalk attenuation (NEXT) | ≥ 61 dB (at 772 kHz) |
| ≥ 59 dB (with 1 MHz) | |
| ≥ 55 dB (at 2 МHz) | |
| ≥ 50 dB (at 4 МHz) | |
| ≥ 46 dB (at 8 МHz) | |
| ≥ 44 dB (at 10 MHz) | |
| ≥ 41 dB (at 16 MHz) | |
| ≥ 40 dB (at 20 МHz) | |
| Attenuation | ≤ 15 dB/km (at 256 kHz) |
| ≤ 24 dB/km (at 772 kHz) | |
| ≤ 27 dB/km (with 1 MHz) | |
| ≤ 52 dB/km (at 4 МHz) | |
| ≤ 84 dB/km (at 10 MHz) | |
| ≤ 112 dB/km (at 16 MHz) | |
| ≤ 119 dB/km (at 20 МHz) | |
| Signal speed | 0.66 c |
| Coupling resistance | < 250.00 mΩ/m (at 30 MHz) |
| Nominal voltage, cable | 250 V (Peak value, not for high-power applications) |
| Test voltage Core/Core | 1500 Vrms |
| Test voltage Core/Shield | 1000 Vrms |
| Flame resistance | according to VDE 0472, Part 4, test type B |
| according to IEC 60332-1 | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| -30 °C ... 70 °C (cable, flexible installation) |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |