View larger
SACC-DSI-FSD-4CON-PG9/0,5 SCO 1551529 PHOENIX CONTACT Bus system flat-type plug
SACC-DSI-FSD-4CON-PG9/0,5 SCO
1551529
PHOENIX CONTACT
1 Pcs.
Cables > Circular connector, mounting (with cable)
Field Device Connectors (FDC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact SACC-DSI-FSD-4CON-PG9/0,5 SCO 1551529 PHOENIX CONTACT Bus system flat-type plug enables fast, secure integration of industrial communication cabling through enclosure partitions. Panel bus connectors ensure standardized linking between modular automation hardware and peripheral nodes. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Cable length (EF000536): 0.5 mm
- Mounting method (EF000003): Back wall mounting
- Ambient temperature (EF002386): 85 °C
- Operating temperature (EF002393): -25 °C
- Rated voltage (EF000228): 250 V
- With shield connection (EF002535): No
- Screw-in thread (EF012303): M12
- Core cross section (EF000018): 0.34 mm²
- Min. number of insertion cycles (EF012212): 100
More info
▲Key Commercial Data
| Orderkey | 1551529 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 42 (C-2-2017) |
| GTIN | 4046356153614 |
| Weight per Piece (excluding packing) | 22.300 g |
| Custom tariff number | 85444290 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 85 °C (Plug / socket) |
|---|---|
| Degree of protection | IP67 |
General
| Note | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
|---|---|
| This product corresponds to the PROFINET Cabling and Interconnection Technology Guideline for PROFINET regulations, version 2.00, order no: 2.252, Chapter 8.2 Connectors for Outside Environment (Balanced cabling) | |
| Rated current at 40°C | 4 A |
| Rated voltage | 250 V |
| Rated surge voltage | 2.5 kV |
| Number of positions | 4 |
| Insulation resistance | ≥ 100 MΩ |
| Coding | D - data |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Status display | No |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Connection method | Individual wires |
| Insertion/withdrawal cycles | ≥ 100 |
| Torque | 3 Nm ... 4 Nm (Installation-side) |
| Mounting type | Rear mounting Pg9 With flat nut |
Material
| Flammability rating according to UL 94 | V0 |
|---|---|
| Contact material | CuZn |
| Contact surface material | Ni/Au |
| Contact carrier material | PA 6.6 |
| Material, knurls | Zinc die-cast, nickel-plated |
| Sealing material | FKM |
Cable
| Cable type | TPE litz wire |
|---|---|
| Conductor cross section | 0.34 mm² |
| AWG signal line | 22 |
| Conductor structure signal line | 7x 0.25 mm |
| Core diameter including insulation | 1.2 mm ±0.07 mm |
| Thickness, insulation | 0.21 mm |
| Wire colors | Yellow, orange, white, blue |
| Material conductor insulation | TPE |
| Conductor material | Tin-plated Cu litz wires |
| Standards/specifications | M12 connector IEC 61076-2-101 |
| Insulation resistance | ≥ 20 MΩ*km |
| Conductor resistance | ≤ 57.6 mΩ/m |
| Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
| Nominal voltage, cable | 300 V |
| Test voltage, cable | 2000 V AC |
| Ambient temperature (operation) | -40 °C ... 85 °C (without mechanical actuation) |
| -40 °C ... 85 °C (cable, fixed installation) | |
| -25 °C ... 85 °C (cable, flexible installation) |
Standards and Regulations
| Standard designation | M12 connector |
|---|---|
| Standards/regulations | IEC 61076-2-101 |
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |