PHOENIX CONTACT SACC-CI-M12FS-8CON-L180-THR SH SACC-CI-M12FS-8CON-L180-THR SH 1551422 PHOENIX CONTACT Flush-type connector View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SACC-CI-M12FS-8CON-L180-THR SH 1551422 PHOENIX CONTACT Flush-type connector

SACC-CI-M12FS-8CON-L180-THR SH

1551422

PHOENIX CONTACT

60 Pcs.

Flush-type connector Plug-in Mounting Connector, 8-Pole, Female Connection, Straight, M12, Coding: A , Printed Circuit Board Mounting, THR Solder Connection, RoHS II Alternative Product Without Exception 6c (Pb< 0.1%) Item Code: 1239981 Contact carrier, 8-position, Socket, straight, M12, coding: A, PCB mounting, THR solder connection, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1239981

Connectors > Contact insert for circular connectors
Field Device Connectors (FDC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact flush-type connector (part number SACC-CI-M12FS-8CON-L180-THR SH) functions as a shielded interface component engineered to connect high-density signal lines to control system circuit boards while protecting against electromagnetic interference. These receptacles are commonly integrated into instrumentation and feedback loops where signal integrity is critical.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Contact insert
  • Application: Signal
  • Number of positions: 8
  • Seal present: yes
  • Shielded: yes
  • Coding: A
  • Thread type: M12
  • Data management status Article revision: 05
  • Insulation characteristics Overvoltage category: III
  • Degree of pollution: 3
  • Rated surge voltage: 0.8 kV
  • Contact resistance: ≤ 3 mΩ
  • Insulation resistance: ≥ 100 MΩ
  • Nominal voltage U N: 30 V
  • Nominal current I N: 2 A
  • Connection method: THR solder connection

More info

▲
Technical data

Notes
Notes on operationThe electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.

Product properties
Product typeContact insert
ApplicationSignal
Number of positions8
Seal presentyes
Shieldedyes
CodingA
Thread typeM12
Data management status
Article revision05
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Electrical properties
Rated surge voltage0.8 kV
Contact resistance≤ 3 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN30 V
Nominal current IN2 A

Connection data
Connection methodTHR solder connection

Material specifications
Flammability rating according to UL 94V0
Seal materialFKM / EPDM
Contact materialCuZn
Contact surface materialAu
Contact carrier materialPPA

Connector
Connection 1
Head designSocket
Head cable outletstraight
Head thread typeM12
CodingA

Cable/line
Ambient temperature (operation)-40 °C ... 85 °C (cable, fixed installation)
-25 °C ... 85 °C (Cable, flexible installation)

Mechanical properties
Mechanical data
Insertion/withdrawal cycles> 100

Environmental and real-life conditions
Ambient conditions
Degree of protection (when plugged in)IP67 (correctly plugged in and locked)
Degree of protectionIP67 (correctly plugged in and locked)
IP67
Ambient temperature (operation)-25 °C ... 85 °C (Plug / socket)
-40 °C ... 85 °C (without mechanical actuation)
-25 °C ... 85 °C (Cable, flexible installation)
-40 °C ... 85 °C (cable, fixed installation)

Standards and regulations
M12
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Mounting
Mounting typePCB mounting

Packaging specifications
Type of packagingTray

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.