HC-B 24-A-DT-PER-F 1648490 PHOENIX CONTACT Terminal adapter
HC-B 24-A-DT-PER-F
1648490
PHOENIX CONTACT
1 Pcs.
Connectors > Contact insert for rectangular connectors
Industrial plug-in connectors/interfaces
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact part number HC-B 24-A-DT-PER-F 1648490 functions as a terminal adapter designed to transition cabinet wiring directly to heavy-duty connector interfaces. Terminal adapters are widely utilized in industrial control panels to simplify complex wiring layouts and streamline the transition from internal terminal blocks to external cable assemblies. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- General: For HEAVYCON-ADVANCE mounting flange and HEAVYCON panel mounting base of B24 type:
- General: Connectors may be operated only when there is no load/voltage.:
- Product type: Terminal adapter:
- Product family: HC-B:
- Series: HC-B:
- Type: B24:
- Number of positions: 24:
- Connection profile: 24+PE:
- Contact numbering: 1 - 24:
- Type: for the right side of the control cabinet:
- Data management status Article revision: 09:
- Insulation characteristics Overvoltage category: III:
- Degree of pollution: 3:
- Rated voltage (III/3): 500 V:
- Rated surge voltage: 6 kV:
- Rated current: 16 A:
More info
▲| General | For HEAVYCON-ADVANCE mounting flange and HEAVYCON panel mounting base of B24 type |
| General | Connectors may be operated only when there is no load/voltage. |
| Product type | Terminal adapter |
| Product family | HC-B |
| Series | HC-B |
| Type | B24 |
| Number of positions | 24 |
| Connection profile | 24+PE |
| Contact numbering | 1 - 24 |
| Type | for the right side of the control cabinet |
| Data management status | |
| Article revision | 09 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Rated voltage (III/3) | 500 V |
| Rated surge voltage | 6 kV |
| Rated current | 16 A |
| SCCR | 5 kA (UL 2237) |
| Connection technology | |
| Connection technology | Push-in connection |
| Conductor connection | |
| Conductor cross section | 0.5 mm² ... 2.5 mm² |
| Connection cross section AWG | 22 ... 12 |
| Stripping length of the individual wire | 10 mm (13 mm with ferrule) |
| Dimensional drawing | |
| Width | 34 mm |
| Height | 72.1 mm |
| Length | 111 mm |
| Drill hole distance, horizontal | 104 mm |
| Drill hole distance, vertical | 27 mm |
| Flammability rating according to UL 94 | V0 |
| Contact material | Copper alloy |
| Contact surface material | Ag |
| Contact carrier material | PA |
| Standards/regulations | PA: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Stripping length of the individual wire | 10 mm (13 mm with ferrule) |
| Mechanical data | |
| Insertion/withdrawal cycles | ≥ 500 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -40 °C ... 125 °C |
| Constructional and testing regulations | DIN EN 61984 |
| DIN EN 60664 | |
| IEC 60352 | |
| Tests | DIN EN 61984 |
| DIN EN 60664 | |
| IEC 60352 | |
| Testing | |
| Standards/regulations | PA: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Assembly note | To ensure correct use, installation in housing with IP54 protection or better is required |
| Connectors may be plugged in only when there is no load/voltage. |