PHOENIX CONTACT PSR-SPP-24DC/URML4/3X1/1X2/B PSR-SPP-24DC/URML4/3X1/1X2/B 2903584 PHOENIX CONTACT Extension module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PSR-SPP-24DC/URML4/3X1/1X2/B 2903584 PHOENIX CONTACT Extension module

PSR-SPP-24DC/URML4/3X1/1X2/B

2903584

PHOENIX CONTACT

1 Pcs.

Extension module Contact extension 1 channel or 2 channel for OSSD signals (e.g. light curtain), 3 NO contacts, 1 NC contact, up to cat.4PLe depending on EN@ISO13849, SIL3 depending on EN62061, plug-in push-in terminal, width: 22.5mm 1- or 2-channel contact extension for OSSD signals (e.g., light grid), 3 N/O contacts, 1 N/C contact, up to Cat. 4 PL e in accordance with EN ISO 13849, SIL 3 in accordance with EN IEC 62061, pluggable Push-in terminal block, width: 22.5 mm

Automation > Device for monitoring of safety-related circuits
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact PSR-SPP-24DC/URML4/3X1/1X2/B is an extension module used to expand the contact capacity of primary safety relays in industrial machine control panels. Expansion modules allow a single safety controller to monitor multiple zones or safely switch higher loads simultaneously. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Note on application Note on application: Only for industrial use
  • Product type: Safety relays
  • Product family: PSRclassic
  • Application: Extension module
  • Mechanical service life: approx. 10 7 cycles
  • Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
  • Data management status Article revision: 06
  • Times Typical response time: 125 ms (For U s autostart)
  • Typical release time: 10 ms (on demand via the sensor circuit)
  • Recovery time: 1 s (following demand of the safety function)
  • Maximum power dissipation for nominal condition: 16.44 W (U S = 26.4 V, I L ² = 72 A², P Total max = 2.04 W + 14.4 W)
  • Nominal operating mode: 100% operating factor
  • Digital: Logic (S12, S22) Description of the input: safety-related
  • Number of inputs: 2
  • Input voltage range "0" signal: 0 V DC ... 5 V DC
  • Input voltage range "1" signal: 20.4 V ... 26.4 V

More info

▲
Technical data

Notes
Note on application
Note on applicationOnly for industrial use

Product properties
Product typeSafety relays
Product familyPSRclassic
ApplicationExtension module
Mechanical service lifeapprox. 107cycles
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Data management status
Article revision06
Times
Typical response time125 ms (For Usautostart)
Typical release time10 ms (on demand via the sensor circuit)
Recovery time1 s (following demand of the safety function)

Electrical properties
Maximum power dissipation for nominal condition16.44 W (US= 26.4 V, IL² = 72 A², PTotal max= 2.04 W + 14.4 W)
Nominal operating mode100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage250 V
Rated surge voltage/insulation4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths.)

Input data
Digital: Logic (S12, S22)
Description of the inputsafety-related
Number of inputs2
Input voltage range "0" signal0 V DC ... 5 V DC
Input voltage range "1" signal20.4 V ... 26.4 V
Input current range "0" signal0 mA ... 2 mA
Inrush currentmax. 110 mA (typically with US, Δt = 3 ms)
Filter timemax. 2 ms (Test pulse width low test pulses, at 100 ms test pulse rate)
No brightness test pulses / high test pulses permitted.
Concurrence∞
Max. permissible overall conductor resistance50 Ω
Protective circuitSuppressor diode
Current consumption38 mA (typical, at 24 V)

Output data
Relay: Enabling current paths (13/14, 23/24, 33/34)
Output description2 N/O contacts each in series, safety-related, floating
Number of outputs3
Contact switching type3 enabling current paths
Contact materialAgSnO2
Switching voltagemin. 10 V
max. 250 V AC/DC
Switching capacitymin. 100 mW
Inrush currentmin. 10 mA
max. 6 A
Switching capacity in accordance with IEC 60947-5-15 A (AC15)
6 A (DC13)
Limiting continuous current6 A (Observe derating and load limit curve)
Sq. Total current72 A2(observe derating)
Switching frequencymax. 0.5 Hz
Mechanical service life10x 106cycles
Output fuse10 A gL/gG
4 A gL/gG (for low-demand applications)
Relay: Signaling current path (41/42)
Output description2 N/C contacts parallel, non-safety-related, floating
Number of outputs1
Contact switching type1 signaling current path
Contact materialAgSnO2
Switching voltagemin. 10 V AC/DC
max. 250 V AC/DC
Switching capacitymin. 100 mW
Inrush currentmin. 10 mA
max. 6 A
Switching capacity in accordance with IEC 60947-5-11.5 A (AC15)
2 A (DC13)
Limiting continuous current6 A
Sq. Total current36 A2
Switching frequencymax. 0.5 Hz
Mechanical service life10x 106cycles
Output fuse6 A gL/gG

Connection data
Connection technology
pluggableyes
Conductor connection
Connection methodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section AWG24 ... 16
Stripping length8 mm

Signaling
Status display2 x LED (green)

Dimensions
Width22.5 mm
Height117.5 mm
Depth114.5 mm

Material specifications
Color (Housing)yellow (RAL 1018)
Housing materialPolyamide

Characteristics
Safety data
Stop category0
Safety data: EN ISO 13849
Category4
Performance level (PL)e (5 A DC13; 5 A AC15; 8760 switching cycles/year)
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL)3
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL)3
Safety data: EN IEC 62061
Safety Integrity Level (SIL)3

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Min. degree of protection of inst. locationIP54
Ambient temperature (operation)-20 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (operation)10 Hz ... 150 Hz, amplitude 0.15 mm, 2g

Approvals
CE
IdentificationCE-compliant

Standards and regulations
Air clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 60947-1

Mounting
Mounting typeDIN rail mounting
Mounting positionvertical or horizontal

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.