View larger
PSR-SPP- 24UC/URM4/5X1/2X2/B 2981046 PHOENIX CONTACT Extension module
PSR-SPP-24UC/URM4/5X1/2X2/B
2981046
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An extension module like the Phoenix Contact PSR-SPP- 24UC/URM4/5X1/2X2/B 2981046 is utilized in industrial automation setups to expand the input and output capabilities of existing safety relay systems. These units help monitor critical circuit paths and allow expansion without fully redesigning the safety architecture.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2981046
- Packing unit: 1 pc
- Catalog page: Page 263 (C-6-2017)
- GTIN: 4017918915520
- Weight per Piece (excluding packing): 20.400 g
- Custom tariff number: 85371098
- Country of origin: DE (Germany)
- Utilization restriction: EMC: class A product, see manufacturer's declaration in the download area
- Width: 22.5 mm
- Height: 112 mm
- Depth: 114.5 mm
- Ambient temperature (operation): -20 °C ... 55 °C (observe derating)
- Ambient temperature (storage/transport): -40 °C ... 70 °C
- Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
- Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
- Maximum altitude: max. 2000 m (Above sea level)
More info
▲Key Commercial Data
| Orderkey | 2981046 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 263 (C-6-2017) |
| GTIN | 4017918915520 |
| Weight per Piece (excluding packing) | 20.400 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | max. 2000 m (Above sea level) |
Input data
| Rated control circuit supply voltage US | 24 V AC/DC -15 % / +10 % |
|---|---|
| Rated control supply current IS | typ. 81 mA AC |
| typ. 71 mA DC | |
| Power consumption at US | typ. 1.94 W (AC) |
| typ. 1.7 W (DC) | |
| Inrush current | 175 mA (Δt = 5 ms at Us) |
| Typ. starting time with Us | < 20 ms (when controlled via A1) |
| Typical release time | < 20 ms (when controlled via A1) |
| Recovery time | < 1 s |
| Operating voltage display | 1 x green LED |
| Protective circuit | Surge protection Varistor |
| Maximum switching frequency | 1 Hz |
| Filter time | 2 ms (at A1 in the event of voltage dips at Us) |
Output data
| Contact type | 5 enabling current paths |
|---|---|
| 1 confirmation current path | |
| 1 signaling current path | |
| Contact material | AgSnO2 |
| Maximum switching voltage | 250 V AC/DC (Observe the load curve) |
| Minimum switching voltage | 5 V AC/DC |
| Limiting continuous current | 6 A (N/O contact, pay attention to the derating) |
| 6 A (N/C contact) | |
| Maximum inrush current | 20 A (Δt 100 ms) |
| Inrush current, minimum | 10 mA |
| Sq. Total current | 72 A2(observe derating) |
| Interrupting rating (ohmic load) max. | 144 W (24 V DC, τ = 0 ms) |
| 288 W (48 V DC, τ = 0 ms) | |
| 110 W (110 V DC, τ = 0 ms) | |
| 88 W (220 V DC, τ = 0 ms) | |
| 1500 VA (250 V AC, τ = 0 ms) | |
| Maximum interrupting rating (inductive load) | 42 W (24 V DC, τ = 40 ms) |
| 42 W (48 V DC, τ = 40 ms) | |
| 42 W (110 V DC, τ = 40 ms) | |
| 42 W (220 V DC, τ = 40 ms) | |
| Switching capacity min. | 50 mW |
| Mechanical service life | 10x 106cycles |
| Switching capacity (360/h cycles) | 4 A (24 V DC) |
| 4 A (230 V AC) | |
| Output fuse | 10 A gL/gG (N/O contact) |
| 6 A gL/gG (N/C contact) |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 20.4 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| IP54 | |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
Connection data
| Connection method | Spring-cage connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
| Designation | EN ISO 13849 |
| Performance level (PL) | e (In conjunction with suitable evaluating device) |
| Category | 4 (In conjunction with suitable evaluating device) |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 (In conjunction with suitable evaluating device) |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178/VDE 0160 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Basic insulation 4 kV: between all current paths and housing Safe isolation, reinforced insulation 6 kV: between A1/A2, 11/12, 23/24, 71/72 and 33/34, 43/44, 53/54, 63/64 |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Conformance | CE-compliant |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |