View larger
PLC-OSC-LPE-24DC/48DC/100 2903171 PHOENIX CONTACT Single-channel pulse expansion module, input: 24 V DC, out..
PLC-OSC-LPE-24DC/48DC/100
2903171
PHOENIX CONTACT
1 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact PLC-OSC-LPE-24DC/48DC/100 Single-channel pulse expansion module, input: 24 V DC, out.. acts as a specialized interface component designed to lengthen short pulse signals in automated production lines. Pulse expanders are commonly deployed in machinery control loops to ensure reliable signal processing by downstream controllers that require longer dwell times. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Input voltage (EF003840): 19.2 V
- Type of voltage (input voltage) (EF003033): DC
- Output voltage (EF003933): 3 V
- Type of output voltage (EF008222): DC
- Rated operation current Ie (EF001443): 0.1 A
- Type of digital output (EF003601): Electronic
- With LED indication (EF005950): Yes
More info
▲Product description
DIP switch settings:
Function
DIP A low - no restart when triggered again (default)
DIP A high - restart when triggered again
DIP B low - input pulse time > 2 ms (default)
DIP B high - input pulse time > 100 us
Pulse expansion times
DIP 1 - 10 ms
DIP 2 - 20 ms
DIP 3 - 40 ms
DIP 4 - 80 ms
DIP 5 - 160 ms
DIP 6 - 320 ms
DIP 7 - 640 ms
DIP 8 - 1280 ms
No DIP switch set: no switching function for the output
If the input signal is longer than the selected time, the output is switched off after removal of the input signal.
The settings are applied after a voltage reset of the rated control supply voltage.
Dimensions
| Width | 6.2 mm |
|---|---|
| Height | 80 mm |
| Depth | 86 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 75 °C |
| Degree of protection | IP20 |
Input data
| "0" signal switching threshold in reference to UC | < 0.4 |
|---|---|
| "1" signal switching threshold in reference to UC | > 0.8 |
| Status display | Yellow LED |
| Operating voltage display | Green LED |
| Type of protection | Protection against polarity reversal |
| Surge protection | |
| Surge voltage protection | > 33 V DC |
Output data
| Output voltage range | 3 V DC ... 48 V DC |
|---|---|
| Limiting continuous current | 100 mA |
| Surge voltage protection | > 54 V DC |
| Voltage drop at max. limiting continuous current | < 1 V DC |
| Output circuit | 3-conductor, ground-referenced |
| Type of protection | Protection against polarity reversal |
| Surge protection | |
| Free running |
Connection data, input side
| Connection name | Input side |
|---|---|
| Connection method | Screw connection |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
General
| Test voltage input/output | 2.5 kVrms(50 Hz, 1 min.) |
|---|---|
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Designation | Air clearances and creepage distances between the power circuits |
| Standards/regulations | DIN EN 50178 |
| Rated insulation voltage | 50 V DC |
| Pollution degree | 2 |
| Overvoltage category | II |