PACT RCP-4000A-UIRO-PT-D95 2906234 PHOENIX CONTACT Current transformer
PACT RCP-4000A-UIRO-PT-D95
2906234
PHOENIX CONTACT
1 Pcs.
Automation > Current transformer
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact PACT RCP-4000A-UIRO-PT-D95 is a current transformer engineered for high-amperage monitoring applications within heavy industrial power systems. Such devices are deployed to capture large alternating current values safely and translate them into usable signals for control instrumentation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated primary current (EF007405): 4000 A
- Calibrated (EF008836): No
- With contact protection (EF008186): No
- Snap mounting (EF007462): No
- With copper rail (EF007380): No
More info
▲Key Commercial Data
| Orderkey | 2906234 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 237 (C-5-2017) |
| GTIN | 4055626048284 |
| Weight per Piece (excluding packing) | 400.600 g |
| Custom tariff number | 85437090 |
| Country of origin | DE (Germany) |
Measuring transducer supply
| Nominal supply voltage | 24 V DC |
|---|---|
| Nominal supply voltage range | 9.6 V DC ... 30 V DC |
| Power consumption | ≤ 1 W (at IOUT= 20 mA, 9.6 V DC, 600 Ω load) |
Measuring coil input data
| Frequency measuring range | 40 Hz ... 20000 Hz |
|---|---|
| Position error | < 1 % |
| Linearity error | 0.1 % |
Measuring transducer input data
| Measuring ranges (current) | 100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A |
|---|---|
| Configurable/programmable | Via DIP switches |
Measuring coil signal output
| Output signal (at 50 Hz) | 100 mV (no load, at 1,000 A) |
|---|---|
| Output voltage (in no-load operation) | VOUT= M * dI/dt |
| Output voltage (sinusoidal, in no-load operation) | 100 mV (VOUT= 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A)) |
Measuring transducer signal output
| Current output signal | 0 mA ... 20 mA (via DIP switch) |
|---|---|
| 4 mA ... 20 mA (via DIP switch) | |
| 0 mA ... 10 mA (via DIP switch) | |
| 2 mA ... 10 mA (via DIP switch) | |
| 0 mA ... 21 mA (can be set via software) | |
| Voltage output signal | 0 V ... 10 V (via DIP switch) |
| 2 V ... 10 V (via DIP switch) | |
| 0 V ... 5 V (via DIP switch) | |
| 1 V ... 5 V (via DIP switch) | |
| 0 V ... 10.5 V (can be set via software) | |
| Load/output load current output | ≤ 600 Ω (20 mA) |
General data, measuring coil
| Length of measuring coil | 300 mm |
|---|---|
| Diameter of measuring coil | 8.3 mm ±0.2 mm |
| Length of signal cable | 3000 mm |
| Conductor structure signal line | 2x 0.22 mm (Signal (tinned)) |
| 1x 0.22 mm (Shielding (tinned)) | |
| Coil material | Elastollan |
| Housing material | PC |
| Insulation | double insulation |
| Rated insulation voltage | 1000 V AC (rms CAT III) |
| 600 V AC (rms CAT IV) | |
| Test voltage | 10.45 kV (DC / 1 min.) |
| Basic accuracy | |
| UL, USA/Canada | UL 61010 Recognized |
General data for measuring transducer
| Maximum transmission error | ≤ 0.5 % (From the range end value) |
|---|---|
| Frequency range | 16 Hz ... 1000 Hz |
| Housing material | PBT |
| Test voltage | 3 kV (50 Hz, 1 min.) |
| UL, USA/Canada | UL 508 Listed |
General data
| Standards/regulations | IEC 61010-1 |
|---|---|
| IEC 61010-2-032 | |
| Degree of pollution | 2 |
| Overvoltage category | II |
| Typical measuring error | < 1 % |
Connection data
| Connection name | Measuring transducer side |
|---|---|
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section AWG min. | 26 |
| Conductor cross section AWG max. | 12 |
| Connection method | Push-in connection |
| Stripping length | 10 mm |
Ambient conditions
| Ambient temperature (operation) | -30 °C ... 80 °C (Measuring coil) |
|---|---|
| -40 °C ... 70 °C (Measuring transducer) | |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C (Measuring coil) |
| -40 °C ... 85 °C (Measuring transducer) | |
| Maximum altitude | > 4000 m |
| Measuring coil degree of protection | IP67 (not assessed by UL) |
| Measuring transducer degree of protection | IP20 |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC Directive 2004/108/EC |
|---|---|
| Noise emission | EN 61000-6-4 |
| Standards/regulations | IEC 61010-1 |
| IEC 61010-2-032 | |
| Rated insulation voltage | 300 V |
| Degree of pollution | 2 |
| Overvoltage category | II |
| Electrical isolation | Reinforced insulation in accordance with IEC 61010-1 |
| Conformance | CE-compliant |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |