View larger
VS-PPC/PL-OE-93K-LI/5,0 1419175 PHOENIX CONTACT Bus system cable
VS-PPC/PL-OE-93K-LI/5,0
1419175
PHOENIX CONTACT
1 Pcs.
Automation > Sensor-actuator patch cord
Field Device Connectors (FDC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact VS-PPC/PL-OE-93K-LI/5,0 is a bus system cable configured to facilitate communication lines between industrial networking infrastructure and specialized machinery. It supports robust digital data exchange protocols across demanding plant layouts. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Data cable preassembled
- Application: Standard
- Sensor type: Sercos
- Number of positions: 4
- No. of cable outlets: 1
- Shielded: yes
- Cable outlet: straight
- Data management status Article revision: 08
- Insulation characteristics Overvoltage category: I
- Degree of pollution: 2
- Status display: no
- Transmission medium: Copper
- Transmission characteristics (category): CAT5
- Transmission speed: 100 Mbps
- Mechanical data Insertion/withdrawal cycles: ≥ 250
- Color: black
More info
▲| Product type | Data cable preassembled |
| Application | Standard |
| Sensor type | Sercos |
| Number of positions | 4 |
| No. of cable outlets | 1 |
| Shielded | yes |
| Cable outlet | straight |
| Data management status | |
| Article revision | 08 |
| Insulation characteristics | |
| Overvoltage category | I |
| Degree of pollution | 2 |
| Status display | no |
| Transmission medium | Copper |
| Transmission characteristics (category) | CAT5 |
| Transmission speed | 100 Mbps |
| Mechanical data | |
| Insertion/withdrawal cycles | ≥ 250 |
| Color | black |
| Flammability rating according to UL 94 | V0 |
| Outer sheath, material | PVC |
| Conductor material | Tin-plated Cu litz wires |
| Connection 1 | |
| Type | Plug straight RJ45 |
| Locking type | Push Pull |
| Material | Plastic |
| Degree of protection | IP67 |
| Connection 2 | |
| Type | free cable end |
| Cable length | 5.00 m |
| Sercos III [93K] | |
| Dimensional drawing | |
| Shielded | yes |
| UL AWM Style | 21694 (60 °C / 600 V) |
| Cable weight | 68 kg/km |
| Cable type | Sercos III |
| Cable type (abbreviation) | 93K |
| Signal type/category | Sercos CAT5 (IEC 11801), 100 Mbps |
| Cable structure | 1x4xAWG22/7, SF/TQ |
| External cable diameter | 6.50 mm ±0.2 mm |
| Outer sheath, material | PVC |
| External sheath, color | signal red RAL 3020 |
| Thickness, outer sheath | approx. 0.90 mm |
| Material, inner sheath | PVC |
| Conductor material | Tin-plated Cu litz wires |
| Conductor structure signal line | 7x 0.25 mm |
| AWG signal line | 22 |
| Conductor cross section | 4x 0.34 mm² |
| Material wire insulation | PE |
| Wire diameter incl. insulation | approx. 1.55 mm |
| Single wire, color | white, yellow, blue, orange |
| Type of pair shielding | Aluminum-lined polyester foil |
| Overall twist | Star quad |
| Shielding | Tinned copper braided shield |
| Nominal voltage, cable | 600 V |
| Test voltage Core/Core | 2000 V (50 Hz, 1 min.) |
| Test voltage Core/Shield | 2000.00 V (50 Hz, 1 min.) |
| Cable resistance | ≤ 120 Ω/km |
| Cable insulation resistance | ≥ 0.5 GΩ*km |
| Coupling resistance | ≤ 20.00 mΩ/m (at 10 Hz) |
| Wave impedance | 100 Ω ±15 Ω (at 100 MHz) |
| Signal runtime | 5.3 ns/m |
| Minimum bending radius, fixed installation | 3 x D |
| Minimum bending radius, flexible installation | 7 x D |
| Resistance to oil | Resistant to oil to a limited extent |
| Flame resistance | according to UL 1685 (CSA FT 4) |
| Other resistance | UV resistant (according to UL 1581, Section 1200) |
| Ambient temperature (operation) | -40 °C ... 70 °C (Cable, flexible installation) |
| -40 °C ... 70 °C (cable, fixed installation) | |
| Ambient conditions | |
| Degree of protection | IP65 |
| IP67 | |
| IP65/IP67 | |
| Ambient temperature (operation) | -40 °C ... 70 °C (cable, fixed installation) |
| -40 °C ... 70 °C (Cable, flexible installation) | |