PHOENIX CONTACT SAC-3P-MR/ 5,0-28R SCO RAIL SAC-3P-MR/ 5,0-28R SCO RAIL 1407300 PHOENIX CONTACT Sensor/actuator cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-3P-MR/ 5,0-28R SCO RAIL 1407300 PHOENIX CONTACT Sensor/actuator cable

SAC-3P-MR/ 5,0-28R SCO RAIL

1407300

PHOENIX CONTACT

1 Pcs.

Sensor/actuator cable Sensor/actuator cable, 3-pole halogen-free, shielded, M12 angled connector, coding: A SPEEDCON, to free cable end, cable length: 5 m, For railway applications Sensor/actuator cable, 3-position, PE-X halogen-free, black, shielded, Plug angled M12 SPEEDCON, coding: A, on free cable end, cable length: 5 m, For railway applications

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A sensor/actuator cable connects industrial field devices, such as proximity switches and control valves, back to centralized I/O modules and controllers. This SAC-3P-MR/ 5,0-28R SCO RAIL 1407300 sensor/actuator cable by Phoenix Contact is built to handle the demanding electrical and mechanical requirements of rolling stock applications.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Sensor/actuator cable
  • Application: Railway applications
  • Number of positions: 3
  • No. of cable outlets: 1
  • Shielded: yes
  • Coding: A
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Flammability rating according to UL 94: V0
  • Material of grip body: PA 6.6
  • Contact material: CuSn
  • Contact surface material: Ni/Au
  • Contact carrier material: PA 6.6
  • Material for screw connection: Zinc die-cast, nickel-plated
  • Insulation resistance: ≥ 100 MΩ
  • Nominal voltage U N: 48 V AC

More info

▲
Technical data

Notes
GeneralFurther products with variable cable type and variable cable length can be found in the accessories section

Product properties
Product typeSensor/actuator cable
ApplicationRailway applications
Number of positions3
No. of cable outlets1
Shieldedyes
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Material of grip bodyPA 6.6
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayno
Status display presentNo

Connection data
Conductor connection
Tightening torque0.4 Nm (M12 connector)

Connector
Connection 1
TypePlug angled M12 SPEEDCON
Number of positions3
Locking typeSPEEDCON
Coding typeA
Connection 2
Typefree cable end

Cable/line
Cable length5 m
Shielded black RADOX® [28R]
Dimensional drawing
Cable weight51 kg/km
Number of positions3
Shieldedyes
Cable typeShielded black RADOX® [28R]
Conductor structure signal line19x 0.18 mm
AWG signal line20
Conductor cross section3x 0.5 mm²
Wire diameter incl. insulation1.43 mm
External cable diameter5.30 mm ±0.3 mm
Outer sheath, materialPE-X
External sheath, colorblack
Conductor materialTin-plated Cu litz wires
Material wire insulationPE-X
Single wire, colorwhite 1, white 2, white 3
Overall twist3 wires, twisted
Max. conductor resistance≤ 40.1 Ω/km
Nominal voltage, cable600 V AC (Core-ground, U0)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, Um)
≤ 900 V DC (Core-ground, V0)
≤ 1500 V DC (Line-line)
Test voltage3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
Minimum bending radius, fixed installation3 x D
Minimum bending radius, flexible installation4 x D
Smallest bending radius, fixed installation16 mm
Smallest bending radius, movable installation22 mm
Halogen-freein accordance with EN 50267-2-1
Flame resistanceEN 60332-1-2
EN 50266
EN 50305, 9.1.2
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Fume corrosivenessEN 50267-2-2
Fume toxicityBS 6853 B.1
EN 50305, 9.2
Concentration of fumesBS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Other resistanceResistance to fuels (according to IRM 903, 168 h at 70 °C)
Ambient temperature (operation)-50 °C ... 120 °C (cable, fixed installation)
-25 °C ... 90 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
Ambient temperature (operation)-40 °C ... 85 °C (Plug / socket)

Standards and regulations
M12
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101
Standard designationShock, vibration
Standards/specificationsEN 50155

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.