View larger
SACB-6Q/4P-SC 1683646 PHOENIX CONTACT Sensor/actuator box
SACB-6Q/4P-SC
1683646
PHOENIX CONTACT
1 Pcs.
Cables > Passive sensor-actuator interface (with cable)
QUICKON Installation System (QPD)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered to streamline industrial connectivity, this Phoenix Contact SACB-6Q/4P-SC sensor/actuator box collects input and output lines from distributed field devices into a single routing hub. These hardware blocks reduce installation complexity and improve system reliability in automated manufacturing cells. Pricing, availability, and delivery terms are confirmed per enquiry via RFQ.
- Orderkey: 1683646
- Packing unit: 1 pc
- Catalog page: Page 273 (C-2-2017)
- GTIN: 4017918170974
- Weight per Piece (excluding packing): 218.200 g
- Custom tariff number: 85366990
- Country of origin: PL (Poland)
- Rated voltage: 120 V
- Max. operating voltage U max: 135 V
- Current carrying capacity per I/O signal: 4 A
- Current carrying capacity per slot: 4 A
- Total rated current: 12 A
- Number of positions: 4
- Number of slots: 6
- Flammability rating according to UL 94: V0
- Sensor/actuator connection system: QUICKON
More info
▲Key Commercial Data
| Orderkey | 1683646 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 273 (C-2-2017) |
| GTIN | 4017918170974 |
| Weight per Piece (excluding packing) | 218.200 g |
| Custom tariff number | 85366990 |
| Country of origin | PL (Poland) |
General
| Rated voltage | 120 V |
|---|---|
| Max. operating voltage Umax | 135 V |
| Current carrying capacity per I/O signal | 4 A |
| Current carrying capacity per slot | 4 A |
| Total rated current | 12 A |
| Number of positions | 4 |
| Number of slots | 6 |
| Flammability rating according to UL 94 | V0 |
| Sensor/actuator connection system | QUICKON |
Master cable data/connection data
| Connection method | Spring-cage connection |
|---|---|
| Conductor cross section min. (signal) | 0.14 mm² |
| Conductor cross section max. (signal) | 1 mm² |
| Conductor cross section AWG min. (signal) | 26 |
| Conductor cross section AWG max. (signal) | 17 |
| Stripping length (signal) | 10 mm |
| Conductor cross section min. (energy) | 0.2 mm² |
| Conductor cross section max. (energy) | 1.5 mm² |
| Conductor cross section AWG min. (energy) | 24 |
| Conductor cross section AWG max. (energy) | 16 |
| External cable diameter min. | 6.5 mm |
| External cable diameter max. | 9.5 mm |
| Stripping length | 70 mm (Master cable) |
| Tightening torque, union nut | 2.5 Nm |
Conductor data
| Structure of individual litz in acc. with VDE 0295 / smallest wire diameter | Class 2-6 // 0.34 mm²: 0.1 mm; 0.5 - 0.75 mm²: 0.15 mm |
|---|---|
| Wire insulation material | PVC / PE |
| Wire diameter including insulation | ≤ 2.5 mm |
| Minimum external conductor diameter | 4 mm |
| Maximum external conductor diameter | 7.5 mm |
| Tightening torque, union nut | 2.5 Nm |
| Wrench size, union nut | 22 mm |
| Note on the frequency of connections | if the conductor is connected more than once, seal and cap may need to be replaced. |
| Conductor cross section flexible min. | 0.34 mm² |
| Conductor cross section flexible max. | 0.75 mm² |
| Conductor cross section AWG min. | 22 |
| Conductor cross section AWG max. | 18 |
Insulation material
| Housing material | PA |
|---|---|
| Material of the moulding mass | PUR |
| Contact material | Steel/copper |
| Contact surface material | Sn |
| Contact carrier material | PA 6.6 |
| Material of contact, master cable side | CuZn |
| Material of contact surface, master cable side | NiSn |
| Material of the contact carrier on the master cable side | PA 6.6 V0 |
Pin assignment
| Slot/position = Wire color or connection | 1 / 4 (A) = 1 / 4 |
|---|---|
| 2 / 4 (A) = 2 / 4 | |
| 3 / 4 (A) = 3 / 4 | |
| 4 / 4 (A) = 4 / 4 | |
| 5 / 4 (A) = 5 / 4 | |
| 6 / 4 (A) = 6 / 4 | |
| 1-6 / 1 (+ 120 V) = UN | |
| 1-6 / 3 (0 V) = 0 V | |
| 1-6 / 5 (PE) = PE |
Standards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |