View larger
SACB-4/ 4-SC SCO P 1452929 PHOENIX CONTACT Sensor/actuator box, Application: Standard, Connection method: M1..
SACB-4/ 4-SC SCO P
1452929
PHOENIX CONTACT
1 Pcs.
Cables > Passive sensor-actuator interface (without cable)
QUICKON Installation System (QPD)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact SACB-4/ 4-SC SCO P sensor/actuator box offers structured signal collection for industrial field devices and control units. These passive junction blocks are utilized across factory floors to minimize point-to-point wiring efforts and ensure dependable communication links in automated processes.
Exact pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Connectable conductor cross section (EF008200): 0.2 mm²
- Cable outer diameter for cable gland (EF007302): 7 mm
- Number of sensor-/actuator-slots (EF006939): 4
- Number of channels per connector slot (EF006885): 1
- Type of branches for sensor-/actuator cables (EF006972): M12
- Number of poles sensor/actuator slots (EF007402): 4
- Operating voltage (EF003983): 120 V
- Max. current carrying capacity per I/O signal (EF004037): 12 A
- Max. total current (EF004039): 12 A
- With LED indication (EF005950): No
- With potential separation (EF003272): No
- Connection for NPN-sensors (EF006817): Yes
More info
▲General
| Rated voltage | 120 V |
|---|---|
| Current carrying capacity per I/O signal | 2 A |
| Current carrying capacity per slot | 4 A |
| Total rated current | 12 A |
| Number of positions | 4 |
| Number of slots | 4 |
| Flammability rating according to UL 94 | V0 |
| Sensor/actuator connection system | M12-SPEEDCON-socket |
Ambient conditions
| Degree of protection | IP65 |
|---|---|
| IP67 | |
| Ambient temperature (operation) | -25 °C ... 80 °C |
Master cable data/connection data
| Connection method | Spring-cage connection |
|---|---|
| Conductor cross section min. (signal) | 0.2 mm² |
| Conductor cross section max. (signal) | 0.5 mm² |
| Conductor cross section AWG min. (signal) | 24 |
| Conductor cross section AWG max. (signal) | 20 |
| Stripping length (signal) | 6 mm |
| Conductor cross section min. (energy) | 0.2 mm² |
| Conductor cross section max. (energy) | 1.5 mm² |
| Conductor cross section AWG min. (energy) | 24 |
| Conductor cross section AWG max. (energy) | 16 |
| Stripping length (power) | 10 mm |
| External cable diameter min. | 7 mm |
| External cable diameter max. | 12 mm |
| Stripping length | 50 mm (Master cable) |
| Tightening torque, cover screw | 1 Nm |
| Tightening torque, union nut | 2.5 Nm |
| Tightening torque slot sensor/actuator cable | 0.4 Nm |
| Tightening torque of mounting screw for fixing the housing | 0.5 Nm |
Insulation material
| Housing material | PBT |
|---|---|
| Material of the moulding mass | PUR |
| Contact material | Cu alloy |
| Contact surface material | Gold-plated |
| Contact carrier material | PA |
| Material of threaded sleeve | PBT |
| O-ring material | NBR |
| Sealing material | NBR (Connector hood) |
Pin assignment
| Slot/position = Wire color or connection | 1 / 4 (A) = WH |
|---|---|
| 2 / 4 (A) = GN | |
| 3 / 4 (A) = YE | |
| 4 / 4 (A) = GY | |
| 1-4 / 1 (+ 120 V) = BN | |
| 1-4 / 3 (0 V) = BU | |
| 1-4 / 5 (PE) = GN/YE |