View larger
SACB-6/12-L-PT SCO P 1412059 PHOENIX CONTACT Sensor/actuator box, Connection method: M12-SPEEDCON-socket Pla..
SACB-6/12-L-PT SCO P
1412059
PHOENIX CONTACT
1 Pcs.
Cables > Passive sensor-actuator interface (without cable)
QUICKON Installation System (QPD)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact SACB-6/12-L-PT SCO P is a sensor/actuator box engineered to handle high-density signal distribution in automated production equipment. Such distribution boxes allow system designers to route multiple sensor lines efficiently while maintaining robust environmental resistance on the factory floor.
Specific pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Connectable conductor cross section (EF008200): 0.2 mm²
- Cable outer diameter for cable gland (EF007302): 7 mm
- Number of sensor-/actuator-slots (EF006939): 6
- Number of channels per connector slot (EF006885): 2
- Type of branches for sensor-/actuator cables (EF006972): M12
- Number of poles sensor/actuator slots (EF007402): 5
- Operating voltage (EF003983): 24 V
- Max. current carrying capacity per I/O signal (EF004037): 8 A
- Max. total current (EF004039): 8 A
- With LED indication (EF005950): Yes
- With potential separation (EF003272): No
- Connection for NPN-sensors (EF006817): No
- Operating temperature (EF002393): -25 °C
- Degree of protection (IP) (EF005474): IP65
- Width (EF000008): 54 mm
- Height (EF000040): 43 mm
More info
▲General
| Rated voltage | 24 V DC |
|---|---|
| Max. operating voltage Umax | 30 V DC |
| Current carrying capacity per I/O signal | 2 A |
| Current carrying capacity per slot | 4 A |
| Total rated current | 8 A (Higher ratings can be achieved with different configurations) |
| Number of positions | 5 |
| Number of slots | 6 |
| Flammability rating according to UL 94 | V0 |
| Sensor/actuator connection system | M12-SPEEDCON-socket |
Ambient conditions
| Degree of protection | IP65 |
|---|---|
| IP67 | |
| Ambient temperature (operation) | -25 °C ... 80 °C |
Local diagnostics function
| Local diagnostics | Supply voltage Green LED |
|---|---|
| Status display I/O Yellow LED |
Master cable connection data
| Connection method | Push-in-/Spring-cage connection |
|---|---|
| Conductor cross section min. (signal) | 0.2 mm² |
| Conductor cross section max. (signal) | 1 mm² |
| Conductor cross section AWG min. (signal) | 24 |
| Conductor cross section AWG max. (signal) | 16 |
| Conductor cross section min. (energy) | 0.2 mm² |
| Conductor cross section max. (energy) | 1 mm² |
| Conductor cross section AWG min. (energy) | 24 |
| Conductor cross section AWG max. (energy) | 16 |
| External cable diameter min. | 7 mm |
| External cable diameter max. | 12 mm |
| Stripping length | 8 mm |
| Tightening torque, cover screw | 1 Nm |
| Tightening torque, union nut | 2.5 Nm |
| Tightening torque slot sensor/actuator cable | 0.4 Nm |
| Tightening torque of mounting screw for fixing the housing | 0.5 Nm |
Insulation material
| Housing material | PBT |
|---|---|
| Material of the moulding mass | PUR |
| Contact material | Cu alloy |
| Contact surface material | Gold-plated |
| Contact carrier material | PA |
| Material of the contact carrier on the master cable side | PA |
| Material of threaded sleeve | PBT |
| O-ring material | NBR |
| Sealing material | NBR (Connector hood) |
Pin assignment
| Slot/position = Wire color or connection | 1 / 4 (A) = WH |
|---|---|
| 1 / 2 (B) = GY/PK | |
| 2 / 4 (A) = GN | |
| 2 / 2 (B) = RD/BU | |
| 3 / 4 (A) = YE | |
| 3 / 2 (B) = WH/GN | |
| 4 / 4 (A) = GY | |
| 4 / 2 (B) = BN/GN | |
| 5 / 4 (A) = PK | |
| 5 / 2 (B) = WH/YE | |
| 6 / 4 (A) = RD | |
| 6 / 2 (B) = YE/BN | |
| 1-4 / 1 (+ 24 V) = BN | |
| 1-6 / 3 (0 V) = BU | |
| 1-6 / 5 (PE) = GN/YE |