Phoenix Contact PSR-SCP- 24UC/THC4/2X1/1X2 2963721 PHOENIX CONTACT Safety relays are specialized electrical control components utilized in industrial automation to reliably interrupt circuits and protect personnel during emergency stop or hazard events. These safety devices continuously monitor machine safeguarding peripherals such as light curtains, safety gates, and emergency buttons, ensuring immediate cessation of hazardous motion when a fault or trip condition is detected. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- With feedback circuit (EF003343): Yes
- With start input (EF003342): Yes
- Suitable for safety functions (EF001597): Yes
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 22.5 mm
- Height (EF000040): 99 mm
- Depth (EF000049): 114.5 mm
More info
▲Key Commercial Data
| Orderkey | 2963721 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 262 (C-6-2017) |
| GTIN | 4017918818692 |
| Weight per Piece (excluding packing) | 193.300 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | max. 2000 m (Above sea level) |
Input data
| Nominal input voltage UN | 24 V AC/DC |
|---|---|
| Input voltage range | 20.4 V AC/DC ... 26.4 V AC/DC |
| Input voltage range in reference to UN | 0.85 ... 1.1 |
| Typical input current at UN | 125 mA AC |
| 60 mA DC | |
| Voltage at input/start and feedback circuit | approx. 24 V DC |
| Typical response time | 50 ms |
| Typical release time | 20 ms |
| Concurrence input 1/2 | < 0.5 s |
| Recovery time | 1 s |
| Operating voltage display | Green LED |
| Status display | Green LED |
| Protective circuit | Fuse PTC resistor |
| Surge protection Suppressor diode |
Output data
| Contact type | 2 enabling current paths |
|---|---|
| 1 signaling current path | |
| Contact material | AgSnO2, + 0.2 µm Au |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 15 V AC/DC |
| Limiting continuous current | 6 A (N/O contact) |
| 5 A (N/C contact) | |
| Maximum inrush current | 6 A |
| Inrush current, minimum | 25 mA |
| Interrupting rating (ohmic load) max. | 144 W (24 V DC, τ = 0 ms) |
| 288 W (48 V DC, τ = 0 ms) | |
| 110 W (110 V DC, τ = 0 ms) | |
| 88 W (220 V DC, τ = 0 ms) | |
| 1500 VA (250 V AC, τ = 0 ms) | |
| Maximum interrupting rating (inductive load) | 42 W (24 V DC, τ = 40 ms) |
| 42 W (48 V DC, τ = 40 ms) | |
| 42 W (110 V DC, τ = 40 ms) | |
| 42 W (220 V DC, τ = 40 ms) | |
| Switching capacity min. | 0.4 W |
| Mechanical service life | approx. 107cycles |
| Switching capacity (360/h cycles) | 4 A (24 V DC) |
| 4 A (230 V AC) | |
| Output fuse | 10 A gL/gG NEOZED (N/O contact) |
| 6 A gL/gG NEOZED (N/C contact) |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 193.3 g |
| Mounting position | any |
| Mounting type | DIN rail mounting |
| Degree of protection | IP20 |
| IP54 | |
| Min. degree of protection of inst. location | IP54 |
| Housing color | yellow |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Type class | IIIC |
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | EN ISO 13849 |
| Performance level (PL) | e |
| Category | 4 |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178/VDE 0160 |
| Rated insulation voltage | 250 V |
| Rated surge voltage/insulation | 6 kV / Safe isolation, increased insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |