View larger
PSR-SCP- 24UC/ESAM4/3X1/1X2/B 2900509 PHOENIX CONTACT Safety relays
PSR-SCP-24UC/ESAM4/3X1/1X2/B
2900509
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for industrial safety functions, this Phoenix Contact PSR-SCP-24UC/ESAM4/3X1/1X2/B safety relay monitors emergency stop circuits and protective door interlocks to safely halt hazardous machinery. Safety relays are foundational elements in machine safeguarding architectures, providing reliable signal processing and immediate power interruption when a risk is detected. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Note on application Note on application: Only for industrial use
- Product type: Safety relays
- Product family: PSRclassic
- Application: Emergency stop
- Mechanical service life: approx. 10 7 cycles
- Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Data management status Article revision: 06
- Maximum power dissipation for nominal condition: 16.44 W (U S = 26.4 V, I L ² = 72 A², P Total max = 2.04 W + 14.4 W)
- Nominal operating mode: 100% operating factor
- Rated surge voltage/insulation: See section “Insulation coordination”
- General Rated control circuit supply voltage U S: 24 V DC -15 % / +10 %
- Power consumption at U S: typ. 1.68 W (DC)
- Rated control supply current I S: typ. 70 mA
- Input voltage range in reference to U N: 0.85 ... 1.1
- Typical input current at U N: 70 mA DC (at Us)
- Inrush current: < 3.5 A (Δt = 3 ms at U s )
More info
▲| Note on application | |
| Note on application | Only for industrial use |
| Product type | Safety relays |
| Product family | PSRclassic |
| Application | Emergency stop |
| Safety door | |
| Mechanical service life | approx. 107cycles |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Data management status | |
| Article revision | 06 |
| Maximum power dissipation for nominal condition | 16.44 W (US= 26.4 V, IL² = 72 A², PTotal max= 2.04 W + 14.4 W) |
| Nominal operating mode | 100% operating factor |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V |
| Rated surge voltage/insulation | See section “Insulation coordination” |
| General | |
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
| Power consumption at US | typ. 1.68 W (DC) |
| Rated control supply current IS | typ. 70 mA |
| Input voltage range in reference to UN | 0.85 ... 1.1 |
| Typical input current at UN | 70 mA DC (at Us) |
| Inrush current | < 3.5 A (Δt = 3 ms at Us) |
| < 100 mA (Δt = 500 ms, with Us/Ixat S12) | |
| > -100 mA (Δt = 300 ms, with Us/Ixat S22) | |
| < 6 mA (with Us/Ixto S34) | |
| < 6 mA (with Us/Ixto S35) | |
| Current consumption | typ. 38 mA (S12) |
| typ. -38 mA (S22) | |
| typ. 0 mA (with Us/Ixto S34) | |
| typ. 1 mA (with Us/Ixto S35) | |
| Voltage at input/start and feedback circuit | approx. 24 V DC |
| Filter time | 5 ms (at A1 in the event of voltage dips at Us) |
| No test pulses permitted | |
| Typical response time | 100 ms (Monitored/manual start) |
| 150 ms (automatic start) | |
| Typ. starting time with Us | 250 ms (when controlled via A1) |
| Typical release time | 20 ms (on demand via the sensor circuit) |
| 45 ms (on demand via A1) | |
| Concurrence | ∞ |
| Recovery time | 1 s (following demand of the safety function) |
| < 1 s (Boot time) | |
| Protective circuit | Surge protection; Suppressor diode |
| Max. permissible overall conductor resistance | approx. 50 Ω (Input and start circuits at US) |
| Operating voltage display | Green LED |
| Status display | LED (green) |
| Contact switching type | 3 enabling current paths |
| 1 signaling current path | |
| Contact material | AgSnO2, + 0.2 µm Au |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 10 V AC/DC |
| Limiting continuous current | 6 A (Observe derating and load limit curve) |
| Maximum inrush current | 6 A |
| Inrush current, minimum | 10 mA |
| Sq. Total current | 72 A2(Enabling current paths) |
| 36 A2(Signaling current path 41/42) | |
| Interrupting rating (ohmic load) max. | see load limit curve |
| Switching capacity min. | 100 mW |
| Switching capacity in accordance with IEC 60947-5-1 | 6 A (DC13, enabling current paths) |
| 5 A (AC15, enabling current paths) | |
| 2 A (DC13, signaling current paths) | |
| 1.5 A (AC15, signaling current paths) | |
| Output fuse | 10 A gL/gG (Enabling current paths) |
| 4 A gL/gG (Low-demand enabling current paths) | |
| 6 A gL/gG (Signaling current path) |
| Connection technology | |
| pluggable | yes |
| Conductor connection | |
| Connection method | Screw connection |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Width | 22.5 mm |
| Height | 99 mm |
| Depth | 114.5 mm |
| Color (Housing) | yellow (RAL 1018) |
| Housing material | Polyamide |
| Safety data | |
| Stop category | 0 |
| Safety data: EN ISO 13849 | |
| Category | 4 |
| Performance level (PL) | e (5 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Safety data: IEC 61508 - High demand | |
| Safety Integrity Level (SIL) | 3 |
| Safety data: IEC 61508 - Low demand | |
| Safety Integrity Level (SIL) | 3 |
| Safety data: EN IEC 62061 | |
| Safety Integrity Level (SIL) | 3 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| CE | |
| Identification | CE-compliant |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | DIN EN 60947-1 |
| Mounting type | DIN rail mounting |
| Assembly note | See derating curve |
| Mounting position | vertical or horizontal |