Safety relays built by Phoenix Contact under part number PSR-SCP-24DC/ESP4/2X1/1X2 are protective switching devices designed to monitor safety circuits and interlocking elements in industrial control systems. These components routinely integrate into machine safety chains to manage fault detection and safely interrupt power to actuators when protective barriers are breached or emergency stops are triggered.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Screw connection
- Suitable for monitoring of position switches (EF007270): Yes
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): Yes
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): Yes
- Release-delay (EF001129): 0.06 s
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 22.5 mm
More info
▲Key Commercial Data
| Orderkey | 2981020 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 288 (C-6-2017) |
| GTIN | 4017918911065 |
| Weight per Piece (excluding packing) | 199.600 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Input data
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
|---|---|
| Rated control supply current IS | typ. 50 mA DC |
| Power consumption at US | 1.2 W |
| Inrush current | 1 A (Δt <10 ms at Us) |
| Typical response time | 60 ms (Automatic/manual start) |
| Typical release time | 20 ms |
| Recovery time | approx. 1 s |
| Operating voltage display | Green LED |
| Status display | Green LED |
| Protective circuit | Surge protection Suppressor diode, 33 V (A1 - A2, Y2 - A2) |
| Reverse polarity protection | |
| Filter time | max. 3 ms (Test pulse duration) |
Output data
| Contact type | 2 enabling current paths |
|---|---|
| 1 signaling current path (type B according to EN 50205) | |
| Contact material | AgSnO2, gold-flashed |
| Maximum switching voltage | 250 V AC/DC (Observe the load curve) |
| Minimum switching voltage | 10 V |
| Limiting continuous current | 6 A (N/O contact/N/C contact, high demand) |
| 4 A (N/O contact, for low-demand applications) | |
| Maximum inrush current | 6 A |
| Inrush current, minimum | 10 mA |
| Sq. Total current | 72 A2(observe derating) |
| Interrupting rating (ohmic load) max. | 144 W (24 V DC, τ = 0 ms) |
| 200 W (48 V DC, τ = 0 ms) | |
| 77 W (110 V DC, τ = 0 ms) | |
| 70 W (220 V DC, τ = 0 ms) | |
| 1500 VA (250 V AC, τ = 0 ms) | |
| Maximum interrupting rating (inductive load) | 42 W (24 V DC, τ = 40 ms) |
| 40 W (48 V DC, τ = 40 ms) | |
| 35 W (110 V DC, τ = 40 ms) | |
| 33 W (220 V DC, τ = 40 ms) | |
| Switching capacity min. | 0.2 W |
| Mechanical service life | approx. 107cycles |
| Switching capacity (360/h cycles) | 5 A (24 V (DC13)) |
| 5 A (230 V (AC 15)) | |
| Output fuse | 6 A gL/gG NEOZED (High demand) |
| 4 A gL/gG NEOZED (Low demand) |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 199.6 g |
| Mounting position | On horizontal and vertical DIN rail |
| Mounting type | DIN rail mounting |
| Degree of protection | IP20 |
| IP54 | |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | EN ISO 13849 |
| Performance level (PL) | e |
| Category | 4 |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178/VDE 0160 |
| Rated insulation voltage | 250 V |
| Rated surge voltage/insulation | 6 kV / Safe isolation, increased insulation |
| Basic insulation 4 kV between all current paths and housing | |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Conformance | CE-compliant |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |