View larger
PSR-SCP-230UC/ESAM4/3X1/1X2/B 2901428 PHOENIX CONTACT Safety relays
PSR-SCP-230UC/ESAM4/3X1/1X2/B
2901428
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built to manage machine safety functions, the PSR-SCP-230UC/ESAM4/3X1/1X2/B 2901428 PHOENIX CONTACT Safety relays device monitors protective door switches, light curtains, and emergency stop chains in industrial environments. These components ensure that automated machinery halts safely whenever an operator breaches a safeguarded zone. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Screw connection
- Suitable for monitoring of position switches (EF007270): Yes
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): Yes
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): Yes
- Release-delay (EF001129): 0.04 s
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 22.5 mm
More info
▲Key Commercial Data
| Orderkey | 2901428 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 260 (C-6-2017) |
| GTIN | 4046356592062 |
| Weight per Piece (excluding packing) | 236.900 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Input data
| Rated control circuit supply voltage US | |
|---|---|
| Nominal input voltage UN | 230 V AC/DC |
| Input voltage range in reference to UN | 0.85 ... 1.1 |
| Typical input current at UN | 22 mA |
| Voltage at input/start and feedback circuit | ~ 24 V DC |
| Typical response time | 40 ms (man. start) |
| Typ. starting time with Us | 330 ms (when controlled via A1) |
| Typical release time | 150 ms (when controlled via A1) |
| 20 ms (when controlled via S11/S12 and S21/S22) | |
| Concurrence input 1/2 | ∞ |
| Recovery time | 1 s |
| Operating voltage display | Green LED |
| Status display | Green LED |
| Protective circuit | Surge protection Varistor 275 VRMS(A1-A2) |
| Surge protection Varistor | |
| Maximum switching frequency | 0.5 Hz |
| Max. permissible overall conductor resistance | 50 Ω |
Output data
| Contact type | 3 enabling current paths |
|---|---|
| 1 signaling current path | |
| Contact material | AgSnO2, + 0.2 µm Au |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 10 V AC/DC |
| Limiting continuous current | 6 A (N/O contact) |
| 5 A (N/C contact) | |
| Maximum inrush current | 6 A |
| Inrush current, minimum | 10 mA |
| Sq. Total current | 72 A2(ITH2= I12+ I22+ I32) |
| Interrupting rating (ohmic load) max. | 144 W (24 V DC, τ = 0 ms) |
| 230 W (48 V DC, τ = 0 ms) | |
| 68 W (110 V DC, τ = 0 ms) | |
| 88 W (220 V DC, τ = 0 ms) | |
| 2000 VA (250 V AC, τ = 0 ms) | |
| Maximum interrupting rating (inductive load) | 48 W (24 V DC, τ = 40 ms) |
| 40 W (48 V DC, τ = 40 ms) | |
| 35 W (110 V DC, τ = 40 ms) | |
| 33 W (220 V DC, τ = 40 ms) | |
| Switching capacity min. | 100 mW |
| Mechanical service life | approx. 107cycles |
| Switching capacity (360/h cycles) | 6 A (24 V DC) |
| 5 A (230 V AC) | |
| Output fuse | 10 A gL/gG NEOZED (N/O contact) |
| 6 A gL/gG NEOZED (N/C contact) |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 236.9 g |
| Mounting position | any |
| Mounting type | DIN rail mounting |
| Degree of protection | IP20 |
| IP54 | |
| Min. degree of protection of inst. location | IP54 |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | EN ISO 13849 |
| Performance level (PL) | e |
| Category | 4 |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 |
| Designation | EN 50156 |
| Safety Integrity Level (SIL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178/VDE 0160 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | 4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV between A1-A2/logic/enabling and signaling current paths) |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |