View larger
PSR-SCP-230AC/ESAM2/3X1/1X2/B 2901430 PHOENIX CONTACT Safety relays
PSR-SCP-230AC/ESAM2/3X1/1X2/B
2901430
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact PSR-SCP-230AC/ESAM2/3X1/1X2/B 2901430 safety relays provide reliable signal monitoring for emergency stop circuits and interlocking safety equipment, ensuring immediate interruption of machine power when triggered. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Screw connection
- Suitable for monitoring of position switches (EF007270): Yes
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): Yes
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): Yes
- Release-delay (EF001129): 0.3 s
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 22.5 mm
More info
▲Key Commercial Data
| Orderkey | 2901430 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 260 (C-6-2017) |
| GTIN | 4046356592185 |
| Weight per Piece (excluding packing) | 23.000 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Input data
| Rated control circuit supply voltage US | |
|---|---|
| Nominal input voltage UN | 230 V AC |
| Input voltage range in reference to UN | 0.85 ... 1.1 |
| Typical input current at UN | 22 mA |
| Voltage at input/start and feedback circuit | ~ 24 V DC |
| Typical response time | 50 ms (manual start) |
| 300 ms (automatic start) | |
| Typ. starting time with Us | 300 ms (when controlled via A1 or S11/S12) |
| Typical release time | 20 ms (when controlled via S11/S12) |
| 150 ms (when controlled via A1) | |
| Recovery time | 1 s |
| Operating voltage display | Green LED |
| Status display | 2 x green LEDs |
| Protective circuit | Surge protection Suppressor diode |
| Surge protection Varistor | |
| Maximum switching frequency | 0.5 Hz |
| Max. permissible overall conductor resistance | 50 Ω |
Output data
| Contact type | 3 enabling current paths |
|---|---|
| 1 signaling current path | |
| Contact material | AgSnO2, gold-flashed |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 10 V AC/DC |
| Limiting continuous current | 6 A (N/O contact) |
| 5 A (N/C contact) | |
| Maximum inrush current | 6 A |
| Inrush current, minimum | 10 mA |
| Sq. Total current | 72 A2(ITH2= I12+ I22+ I32) |
| Interrupting rating (ohmic load) max. | 144 W (at 24 V DC) |
| 230 W (at 48 V DC) | |
| 68 W (at 110 V DC) | |
| 88 W (at 220 V DC) | |
| 2000 VA (for 250 V AC) | |
| Maximum interrupting rating (inductive load) | 48 W (at 24 V DC) |
| 40 W (at 48 V DC) | |
| 35 W (at 110 V DC) | |
| 33 W (at 220 V DC) | |
| Switching capacity min. | 100 mW |
| Mechanical service life | approx. 107cycles |
| Switching capacity (360/h cycles) | 6 A (24 V DC) |
| 5 A (230 V AC) | |
| Output fuse | 10 A gL/gG NEOZED (Enabling current paths) |
| 6 A gL/gG NEOZED (Signaling current paths) |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 23 g |
| Mounting position | any |
| Mounting type | DIN rail mounting |
| Degree of protection | IP20 |
| IP54 | |
| Min. degree of protection of inst. location | IP54 |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Safety Integrity Level (SIL) | 1 (up to SIL 3 depending on the application) |
| 1 (up to SIL 3 depending on the application) | |
| Designation | EN ISO 13849 |
| Performance level (PL) | c (up to PL e depending on the application) |
| Category | 1 (up to Cat. 4 depending on the application) |
| Safety Integrity Level Claim Limit (SIL CL) | 1 (up to SILCL 3 depending on the application) |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178/VDE 0160 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | 4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV between A1-A2/logic/enabling and signaling current paths) |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |