This Phoenix Contact AXL F PSDI8/4 1F safety module functions as an intelligent processing node within Axioline F industrial automation stations, evaluating safety-related signals from emergency stops or light curtains. Safety modules are essential for monitoring hazardous machine zones and executing reliable interlock reactions.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Width: 53.6 mm
- Height: 126.1 mm
- Depth: 54 mm
- Note on dimensions: Housing dimensions
- Note on application Note on application: Only for industrial use
- Axioline F local bus Connection method: Bus base module
- Module Input address area: 5 Byte
- Output address area: 5 Byte
- Required parameter data: 22 Byte ((I-and F-parameters))
- Required configuration data: 10 Byte
- Digital: Input name: Digital inputs
- Description of the input: IEC 61131-2 type 3
- Number of inputs: 4 (for 2-channel assignment)
- Connection method: Push-in connection
- Connection technology: 2-, 3-, 4-conductor
- Input voltage: 24 V DC (via clock outputs T1 and T2 or external supply)
More info
▲| Dimensional drawing | |
| Width | 53.6 mm |
| Height | 126.1 mm |
| Depth | 54 mm |
| Note on dimensions | Housing dimensions |
| Note on application | |
| Note on application | Only for industrial use |
| Axioline F local bus | |
| Connection method | Bus base module |
| Module | |
| Input address area | 5 Byte |
| Output address area | 5 Byte |
| Required parameter data | 22 Byte ((I-and F-parameters)) |
| Required configuration data | 10 Byte |
| Digital: | |
| Input name | Digital inputs |
| Description of the input | IEC 61131-2 type 3 |
| Number of inputs | 4 (for 2-channel assignment) |
| 8 (for 1-channel assignment) | |
| Cable length | max. 1000 m (200 m from the clock output to the safe input (total based on forward and return path)) |
| Connection method | Push-in connection |
| Connection technology | 2-, 3-, 4-conductor |
| Input voltage | 24 V DC (via clock outputs T1 and T2 or external supply) |
| Input voltage range | -3 V DC ... 30 V DC |
| Nominal input voltage UIN | 24 V DC |
| Nominal input current at UIN | typ. 4.2 mA |
| Typical input current per channel | 4.2 mA |
| Input filter time | 1.5 ms |
| 3 ms (Default) | |
| 5 ms | |
| 15 ms | |
| Product type | I/O component |
| Product family | Axioline F |
| Application | Functional safety |
| PROFIsafe | |
| only for connection to Phoenix Contact or Siemens controller | |
| Type | modular |
| Data management status | |
| Article revision | 12 |
| Maximum power dissipation for nominal condition | 2 W |
| Transmission medium | Copper |
| Potentials | |
| Protective circuit | Protection against polarity reversal, EMC protective circuit, undervoltage detection |
| Potentials: Axioline F local bus supply (UBus) | |
| Supply voltage | 5 V DC (via bus base module) |
| Current draw | max. 310 mA |
| typ. 280 mA (all inputs set; supply by UIof 19.2 V DC ... 30 V DC) | |
| Potentials: Supply for digital input modules (UI) | |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current draw | typ. 9 mA (all inputs set; supply from UIwith 30 V DC; without supply to the sensors via clock supplies T1 and T2) |
| Connection technology | |
| Connection name | Axioline F connector |
| pluggable | yes |
| Conductor connection | |
| Connection method | Push-in connection |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
| Axioline F connector | |
| Connection method | Push-in connection |
| Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
| Ambient conditions | |
| Ambient temperature (operation) | -35 °C ... 60 °C (Mounting position: any) |
| Degree of protection | IP20 |
| Air pressure (operation) | 70 kPa ... 108 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 75 % (on average, 85% infrequently, non-condensing) |
| Permissible humidity (storage/transport) | 10 % ... 75 % (non-condensing) |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Mounting type | DIN rail mounting |