View larger
IB IL 24 PSDOR 4-PAC 2985864 PHOENIX CONTACT Safety-oriented decentral relay output module, IP20 degree of p..
IB IL 24 PSDOR 4-PAC
2985864
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - digital I/O module
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact IB IL 24 PSDOR 4-PAC 2985864 PHOENIX CONTACT Safety-oriented decentral relay output module, IP20 degree of p.. acts as a safety-rated switching interface designed to interrupt hazardous machine motion when tripped. Decentralized safety relay modules provide reliable power disconnection to critical loads, fulfilling safety integrity requirements in industrial machine safeguarding.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Voltage type (supply voltage) (EF002991): DC
- Number of digital inputs (EF001992): 0
- Number of digital outputs (EF001993): 0
- Digital inputs configurable (EF008516): No
- Digital outputs configurable (EF008520): No
- Type of voltage (input voltage) (EF003033): DC
- Short-circuit protection, outputs available (EF003203): No
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
- Number of HW-interfaces serial TTY (EF003024): 0
- Number of HW-interfaces parallel (EF003026): 0
- Number of HW-interfaces wireless (EF006933): 0
More info
▲Product description
The safety module is an output module from the Inline product range, designed for use in an INTERBUS-Safety or PROFIsafe system. The safety module can be used as part of an Inline station at any point within an INTERBUS-Safety or PROFIsafe Inline system.
The transmission speed of the safety module can be set to 500 kbaud or 2 Mbaud using a switch. Only one transmission speed must be used uniformly within a station. The module has four safe digital relay outputs, each with two relay contacts. The outputs can be parameterized according to the application and enable the integration of actuators in the safe INTERBUS system (INTERBUS-Safety) and in the PROFIsafe system.
The safety-related segment circuit can be switched on or off using suitable wiring.
When the output is switched off, the supply to the subsequent modules is disconnected safely.
The module also has two clock outputs with assigned alarm inputs for monitoring external contact extensions.
Depending on the installation and parameterization, in these systems the safety module can achieve the following safety integrity:
– Up to category 4 according to standard EN 954-1
– Up to SIL 3 according to standards EN 61508 and EN 62061
– Up to PL e according to standard EN ISO 13849-1
Dimensions
| Width | 73.2 mm |
|---|---|
| Height | 119.8 mm |
| Depth | 71.5 mm |
| Note on dimensions | Housing dimensions |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 70 °C |
| Permissible humidity (operation) | 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.) |
| Permissible humidity (storage/transport) | 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.) |
| Air pressure (operation) | 80 kPa ... 108 kPa (up to 2000 m above sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above mean sea level) |
| Degree of protection | IP20 |
Interfaces
| Fieldbus system | INTERBUS |
|---|---|
| Designation | Inline local bus |
| Connection method | Inline data jumper |
| Transmission speed | 500 kBit/ / 2 MBit/s (can be switched) |
Digital outputs
| Output name | Relay output |
|---|---|
| Connection method | Spring-cage connection |
| 2-wire | |
| Number of outputs | 4 (Safety relays) |
| Output voltage | 24 V DC (US- 1 V) |
| Nominal output voltage | 24 V DC (Inline connector) |
| Output current | max. 4 A (Inline connector, pro contact, observe derating) |
| max. 6 A (COMBICON connector, pro contact, observe derating) | |
| Maximum output current per channel | 4 A |
Power supply for module electronics
| Supply voltage | 24 V DC (via voltage jumper) |
|---|---|
| Supply voltage range | 19.2 V DC ... 30 V DC |
| Communications power UL | 7.5 V (via voltage jumper) |
| Current consumption | max. 360 mA (from the local bus) |
General
| Net weight | 386 g |
|---|---|
| Note on weight specifications | with connectors |
| Mounting type | DIN rail |
| Category according to EN 13849-1 | 4 |
Inline potentials
| Communications power UL | 7.5 V DC (see safety data) |
|---|---|
| Current consumption from UL | max. 360 mA |
| Main circuit supply UM | 24 V DC |
| Supply voltage range UM | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption from UM | typ. 30 mA (all outputs set including actuator current) |
| max. 0.03 A | |
| Segment supply voltage US | 24 V |