The SACC-DSI-M12MST-4CON-M16/1,0 1037080 PHOENIX CONTACT Flush-type connector, Power, 4-position, Plug, M12, T p.. provides a compact device-side interface for power distribution in compact drives and sensors. Equipment manufacturers integrate these panel receptacles to maintain standardized, threaded connection points directly on device housings.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Order information:: Lock nut is included in the scope of delivery
- Mounting type: Rear mounting
- Assembly note: With flat nut
- Product type: Circular connectors (device side)
- Sensor type: Power
- Number of positions: 4
- No. of cable outlets: 1
- Shielded: no
- Coding: T
- Thread type: M12
- Data management status Article revision: 05
- Insulation characteristics Overvoltage category: III
- Degree of pollution: 3
- Flammability rating according to UL 94: V0
- Seal material: FKM
- Contact material: CuZn
More info
▲| Notes on operation | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
| Order information: | Lock nut is included in the scope of delivery |
| Mounting type | Rear mounting |
| Assembly note | With flat nut |
| Product type | Circular connectors (device side) |
| Sensor type | Power |
| Number of positions | 4 |
| No. of cable outlets | 1 |
| Shielded | no |
| Coding | T |
| Thread type | M12 |
| Data management status | |
| Article revision | 05 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Flammability rating according to UL 94 | V0 |
| Seal material | FKM |
| Contact material | CuZn |
| Contact surface material | Au |
| Contact carrier material | PA |
| Material for screw connection | CuZn alloy, nickel-plated |
| Conductor material | Bare Cu litz wires |
| Rated surge voltage | 1.5 kV |
| 1.5 kV AC/DC | |
| Contact resistance | ≤ 3 mΩ |
| Insulation resistance | ≥ 100 MΩ |
| Nominal voltage UN | 63 V |
| Nominal current IN | 12 A |
| Test voltage | 1.5 kV |
| Conductor connection | |
| Connection method | Individual wires |
| Contact connection type | Pin |
| Conductor cross section | 1.31 mm² |
| Tightening torque | M12 connector |
| Mechanical data | |
| Insertion/withdrawal cycles | > 100 |
| Connection 1 | |
| Head design | Pin |
| Head thread type | M12 |
| Coding | T |
| Connection 2 | |
| Head design | free cable end |
| Cable length | 1 m |
| Cable type | UL/cUL stranded hook-up wire |
| Signal type/category | Power |
| Wire diameter incl. insulation | 2 mm |
| Single wire, color | black, brown, blue, white |
| Cable cross section | 1.31 mm² |
| Conductor material | Bare Cu litz wires |
| AWG signal line | 16 |
| Material wire insulation | mPPE |
| Halogen-free | yes |
| Flame resistance | in acc. to UL 1581 VW1 |
| Ambient temperature (operation) | -40 °C ... 105 °C (cable, fixed installation) |
| -20 °C ... 105 °C (Cable, flexible installation) |
| Ambient conditions | |
| Degree of protection | IP67 |
| IP65/IP67 | |
| Ambient temperature (operation) | -25 °C ... 85 °C (Plug / socket) |
| -20 °C ... 105 °C (Cable, flexible installation) | |
| -40 °C ... 105 °C (cable, fixed installation) | |
| Flame resistance | in acc. to UL 1581 VW1 |
| M12 | |
| Standard designation | M12 connector |
| Standards/specifications | IEC 61076-2-111 |