SACC-DSI-M12MS-5CON-M16/0,5 SHS 1426132 PHOENIX CONTACT Male mounting mainstream. p/ sensors/actuators 5-pin..
SACC-DSI-M12MS-5CON-M16/0,5 SHS
1426132
PHOENIX CONTACT
1 Pcs.
Connectors > Sensor-actuator connector chassis
Field Device Connectors (FDC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact SACC-DSI-M12MS-5CON-M16/0,5 SHS male mounting connector provides a standardized interface for sensors and actuators directly integrated into equipment housings. Device-side circular connectors are commonly utilized on control cabinets, junction boxes, and motor housings to establish dependable, shielded communication paths.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of mounting: Rear wall mount
- Installation instructions: with flat nut
- Product Type: Circular connectors (equipment side)
- Sensor Type: Universal
- Number of poles: 5
- Number of Cable Outlets: 1
- Shielded: No
- Codification: to
- Insulation Properties Surge Category: Ii
- Degree of pollution: 3
- Flammability class according to UL 94: V0
- Gasket material: FKM
- Contact material: CuZn
- Material: Contact Surface: Au
- Contact Support Material: AP 6.6
- Screw connection material: Zinc die-cast iron, nickel-plated
More info
▲| Observation regarding the operation | The electrical and mechanical values listed require a pair of plug-in connectors that are properly assembled and locked. If the plug-in connector is unlocked and there is a danger of contamination, the plug-in connector must be closed with a cap > IP54. In addition, influences by conductors, lines, or assembly of printed circuit boards must be considered. |
| Safety Indication | |
| Safety Notes | WARNING: Connectors should not be plugged in or unplugged under load. Failure to comply and improper use can result in property damage and personal injury. |
| • WARNING: Serve only products in perfect condition. Products should be checked regularly for damage. Remove defective products immediately. Replace damaged products. It is not possible to repair them. | |
| • WARNING: only qualified personnel specialized in electrical engineering can install and use the product, always taking into account the following safety indications. Specialized personnel must be familiar with the fundamentals of electrical engineering. You must be able to identify and avoid hazards. The corresponding symbol on the packaging indicates that personnel specialized in electrical engineering are required for installation and operation. | |
| • The products are suitable for the areas of application of the construction of electrical equipment, control systems and systems. | |
| • If connectors are used outdoors, they must be protected in particular from environmental influences. | |
| • Ready-made products may not be tampered with or opened in an unauthorized manner. | |
| • Use only mating connectors that comply with the technical data of the specified standards (e.g. those indicated on the product accessories on the website on phoenixcontact.com/products). | |
| • The user is responsible for using the product directly in conjunction with products from other manufacturers. | |
| • With operating voltages > 50 V AC, electrically conductive connector housings must be grounded | |
| • When laying the cable, check that the tensile load applied to the connectors does not exceed the limits set out in the standards. | |
| • Please note the relevant technical data. You will find the data: or in the product or on the packaging label or in the documentation provided or on the website phoenixcontact.com/products by selecting the product | |
| • Only use the tool recommended by Phoenix Contact | |
| • Do not close plugged-in connectors with a cap. You will find the right accessory in the accessories section of the article, under phoenixcontact.com/products | |
| • Check that the functional or protective ground is properly connected. | |
| • When grouping several electrical circuits together in one cable and/or connector, VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 apply | |
| • The connector heats up during normal operation. Depending on the ambient conditions, the surface of the connector may also heat up. In this case, the user will be responsible for affixing the warning indications (e.g. DIN EN ISO 13732-1:2008-12). | |
| Type of mounting | Rear wall mount |
| Installation instructions | with flat nut |
| Product Type | Circular connectors (equipment side) |
| Sensor Type | Universal |
| Number of poles | 5 |
| Number of Cable Outlets | 1 |
| Shielded | No |
| Codification | to |
| Insulation Properties | |
| Surge Category | Ii |
| Degree of pollution | 3 |
| Flammability class according to UL 94 | V0 |
| Gasket material | FKM |
| Contact material | CuZn |
| Material: Contact Surface | Au |
| Contact Support Material | AP 6.6 |
| Screw connection material | Zinc die-cast iron, nickel-plated |
| Conductive Material | Tinned Cu Conductor |
| Dimensioning Transient Voltage | 1.5 kV |
| Contact resistance | ≤ 3 mΩ |
| Insulation resistance | ≥ 100 MΩ |
| Nominal voltage UN | 60 V |
| Nominal Current IN | 4 A |
| Max. Conductor Resistance | 57.6 mΩ/m |
| Connecting Conductors | |
| Connection type | Single braided threads |
| Tightening torque | 3 Nm ... 4 Nm (on the mounting side) |
| Mechanical data | |
| Plug Cycles | > 100 |
| Connection 1 | |
| Header construction | Male connector |
| Header thread type | M12 |
| Codification | to |
| Cable length | 0.5 m |
| Cable type | TPE braided yarn |
| Signal Type/Category | Universal |
| Conductor diameter incl. insulation | 1.2 mm ±0.07 mm |
| Single Driver, Color | black, brown, blue, white, gray |
| Line Section | 0.34 mm² |
| Conductive Material | Tinned Cu Conductor |
| Conductor Construction Signal Cable | 7x 0.25 mm |
| AWG Signal Line | 22 |
| Material: Conductor Insulation | TPE |
| Wall Thickness Insulation | 0.21 mm (Conductor Insulation) |
| Nominal Voltage Cable | 300 V |
| Test Voltage Cable | 2000 V AC |
| Line Resistance | ≤ 57.6 mΩ/m |
| Line Insulation Resistance | ≥ 20 MΩ*km |
| Ambient Temperature (Service) | -40 °C ... 85°C (cable, fixed arrangement) |
| -25°C ... 85°C (Cable, Mobile Arrangement) |
| Environmental conditions | |
| Protection Index | IP67 (In plugged in state) |
| IP65 (In plugged in state) | |
| IP65/IP67 | |
| Ambient Temperature (Service) | -25 °C ... 85°C (male/female) |
| -40 °C ... 85°C (without mechanical drive) | |
| -25°C ... 85°C (Cable, Mobile Arrangement) | |
| -40 °C ... 85°C (cable, fixed arrangement) | |
| M12 | |
| Denomination of standard | M12 connector |
| Rules/Provisions | IEC 61076-2-101 |