PHOENIX CONTACT SACB-6/ 6-40,0PUR SCO SACB-6/ 6- 40,0PUR SCO 1532900 PHOENIX CONTACT Distribution box, application: Standard, number of plug-in st.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SACB-6/ 6- 40,0PUR SCO 1532900 PHOENIX CONTACT Distribution box, application: Standard, number of plug-in st..

SACB-6/ 6-40,0PUR SCO

1532900

PHOENIX CONTACT

10 Pcs.

Distribution box, application: Standard, number of plug-in stations: 6, number of poles: 4, coding: A, occupation of plug-in stations: simple, status indication: No. main cable connection: Fixed connection 180°, PUR/PVC, cable length: 40 m, shielding: no Distributor box, application: Standard, number of slots: 6, number of positions: 4, coding: A, slot assignment: single, status display: No; master cable connection: Fixed connection 180°, PUR/PVC, cable length: 40 m, shielding: no

Cables > Passive sensor-actuator interface (with cable)
QUICKON Installation System (QPD)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Streamline machine wiring architectures using the Phoenix Contact SACB-6/ 6-40,0PUR SCO distribution box, designed to centralize multiple field device connections in automation systems. Distribution boxes reduce wiring complexity by consolidating sensor and actuator signals into a single trunk line.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Distributor boxes with M8 to M12 slots
  • Number of positions: 4
  • Application: Standard
  • Number of slots: 6
  • Coding: A
  • Material: Die-cast zinc
  • Flammability rating according to UL 94: V0
  • Seal material: NBR
  • Contact material: Cu alloy
  • Contact surface material: gold-plated
  • Contact carrier material: PA
  • Conductor connection Connection method: Fixed connection
  • Status display present: No
  • Max. operating voltage U max: 135 V
  • Nominal voltage U N: 120 V AC
  • Rated current, total: 12 A

More info

▲
Technical data

Notes
GeneralNOTE:Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties.
GeneralUnused slots are to be sealed off prior to commissioning. Suitable sealing elements are to be found under "Accessories".

Product properties
Product typeDistributor boxes with M8 to M12 slots
Number of positions4
ApplicationStandard
Number of slots6
CodingA

Material specifications
MaterialDie-cast zinc
PBT
PUR
Flammability rating according to UL 94V0
Seal materialNBR
Contact materialCu alloy
Contact surface materialgold-plated
Contact carrier materialPA

Connection data
Conductor connection
Connection methodFixed connection

Signaling
Status display presentNo

Electrical properties
Max. operating voltage Umax135 V
Nominal voltage UN120 V AC
120 V DC
Rated current, total12 A
Max. current carrying capacity per path2 A
Current carrying capacity per slot4 A

Cable/line
Cable length40 m
PUR/PVC black [PUR]
Dimensional drawing
Shieldedno
UL AWM Style20549
Cable weight96.6 kg/km
Cable typePUR/PVC black
Short symbolLiYY11Y-HF
Cable type (abbreviation)PUR
External cable diameter8 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorblack RAL 9005
Material, inner sheathPVC
Conductor materialBare Cu litz wires
Conductor structure signal line19x 0.15 mm
AWG signal line22
Conductor structure, voltage supply42x 0.15 mm
Conductor cross section6x 0.34 mm² (Signal line)
AWG power supply18
Material wire insulationPVC
Thickness, insulation≥ 0.15 mm (Inner sheath)
Wire diameter incl. insulation1.3 mm ±0.1 mm (Signal line)
1.8 mm ±0.1 mm (power line)
Single wire, colorbrown, blue, green/yellow, white, green, yellow, gray, pink, red
Overall twistWires twisted in layers
Nominal voltage, cable300 V
Test voltage, cable2000 V
Minimum bending radius, fixed installation7.5 x D
Minimum bending radius, flexible installation10 x D
Number of bending cycles1500000
Bending radius80 mm
Traversing path2 m
Traversing rate2 m/s
Resistance to oilaccording to VDE 0472 Part 803
Flame resistanceDIN EN 50265
Other resistanceHighly resistant to acids, alkaline solutions and solvents
Special propertiesSilicone-free
Ambient temperature (operation)-5 °C ... 80 °C (Cable, flexible installation)
-40 °C ... 90 °C (cable, fixed installation)

Standards and regulations
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
IP69K
Ambient temperature (operation)-30 °C ... 90 °C

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.