View larger
SAC-8P-MS/ 3,5-PUR SH SCO 1426523 PHOENIX CONTACT Cable for sensors/actuators, 8-pole, PUR halogen-free, bla..
SAC-8P-MS/ 3,5-PUR SH SCO
1426523
PHOENIX CONTACT
25 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact cable for sensors/actuators part number SAC-8P-MS/ 3,5-PUR SH SCO provides secure, shielded signal transmission for multi-wire control loops in industrial automation environments. Factory-molded connector cables safeguard data integrity against electrical noise. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: One million four hundred twenty six thousand five hundred twenty three
- Packing unit: 1 PCS
- Sales key: BF1CMA -
- Minimum order quantity: 25 PCS
- Weight per piece (package included): 22,220 g
- Custom tariff number: Eighty five million four hundred forty four thousand two hundred ninety
- Length of cable: 3.5 m
- Ambient temperature (operation): -25 °C ... 90 °C (plug / connector female)
- Rated current at 40 ℃: Two
- Rated voltage: 30 V AC
- Number of positions: Eight
- Insulation resistance: ≥ 100 MΩ
- Coding: A - standard
- Standards/regulations: M12 connector IEC 61076-2-101
- Status display: No
- Protective circuit/component: without circuit
More info
▲Cable, sensor-actuator, 8-pin, PUR without halogenated, black-grey RAL 7021, shielded, straight Male M12 SPEEDCON, A-coded, on the ends of conductor the free, cable length: 3.5 m
Commercial data
| The code for the order | One million four hundred twenty six thousand five hundred twenty three |
|---|---|
| Pieces/pack. | 1 PCS |
| Sales key | BF1CMA - |
| The amount of minimum order | 25 PCS |
| GTIN | Four trillion fifty five billion six hundred twenty six million four hundred sixty three thousand one |
| Weight per piece (package included) | 22,220 g |
| Number customs tariff | Eighty five million four hundred forty four thousand two hundred ninety |
Size
| Length. cable | 3.5 m |
|---|
Environmental conditions
| Ambient temperature (operation) | -25 °C ... 90 °C (plug / connector female) |
|---|
General
| Rated current at 40 ℃ | Two |
|---|---|
| Rating voltage | 30 V AC |
| 30 V DC | |
| N. of poles | Eight |
| Insulation resistance | ≥ 100 MΩ |
| Encoding | A - standard |
| Rules/Provisions | M12 connector IEC 61076-2-101 |
| Signalling status of | No |
| Circuit/component protection | without circuit |
| Overvoltage category | II |
| Pollution degree | Three |
| Number of operating cycles, | ≥ 100 |
Material
| Class behaviour according to UL 94 | HB |
|---|---|
| Contact material | CuZn |
| Material surface contacts | Ni/Au |
| Insert material latch | TPU GF |
| Material handles | TPU, hardly inflammable, self-extinguishing |
| Nut material | Zinc die-cast, nickel-plated |
Regulations and requirements
| Definition standard | M12 Connector |
|---|---|
| Rules/Provisions | IEC 61076-2-101 |
| Class behaviour according to UL 94 | HB |
Cable
| Cable type | EVEN without halogenated black |
|---|---|
| Cable type (abbreviation) | WHILE |
| Abbreviation cables | LiF9YC11Y |
| UL AWM Style | 20549 / 10493 (80 °C / 300 V) |
| Conductor cross section | 8x 0.25 mm2 (signal Line) |
| Signal line AWG | Twenty four |
| Tree conductor signal line | 32x 0.10 mm |
| Wire diameter including insulation | 1.17 mm ±0.02 mm |
| Insulation wall thickness | ca. 0.2 mm |
| Color wire | brown, white, green, yellow, grey, pink, blue, red |
| Lay the entire | 8 wires around filler to the soul |
| Shielding | Wire braid tinned copper |
| Cover screen optical | 85 % |
| External sheath, color | grey-black RAL 7021 |
| Wall thickness outer jacket | ca. 0.5 mm |
| Cable outer diameter D | 5.9 mm ±0.2 mm |
| Bend radius, minimum, fixed | 5 x D |
| Bend radius, minimum, flexible | 10 x D |
| The number of cycles of bending | Two million |
| Bend radius, minimum, insert cable drag chains | 10 x D |
| Positioning movement | 10 m |
| Positioning speed | 3 m/s |
| Acceleration | 10 m/s2 |
| The weight of the cable | 53 kg/km |
| Outer sheath, material | WHILE |
| Material insulation wire | PP |
| The conductive material | Cu wire bare |
| Insulation resistance | ≥ 1 GΩ*km (at 20 °C) |
| resistance of the conductor | ≤ 78 Ω/km (at 20 °C) |
| Rated voltage of cable | ≤ 300 V AC |
| Test voltage cable | ≥ 3000 V AC (Spark test) |
| Test voltage wire/shield | ≥ 2000 V AC (for 60 s) |
| Special features | drag chain |
| Flame resistance | in accordance with UL FT-2 |
| according to the UL 758/1581 (horizontal) | |
| according to the UL 758/1581 FT2 | |
| according to DIN EN 60332-2-2 (20 s) | |
| The absence of halogens | according to DIN VDE 0472 Part 815 |
| in accordance with DIN EN 50267-2-1 | |
| The other resistance | Resistance to hydrolysis and microbes |
| sea-water resistant | |
| non-adherent | |
| non-adherent | |
| UV-resistant in accordance with DIN EN ISO 4892-2-A | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| -25 °C ... 80 °C (cable, mobile installation) |
Environmental Product Compliance
| REACh SVHC | |
|---|---|
| Lead 7439-92-1 | |
| China RoHS | Period for proper use: unlimited = EFUP-and |
| Any hazardous substances above the threshold values |
Rankings
eCl@ss
| eCl@ss 6.0 | Twenty seven million two hundred seventy nine thousand two hundred |
|---|---|
| eCl@ss 7.0 | Twenty seven million two hundred seventy nine thousand two hundred eighteen |
| eCl@ss 9.0 | Twenty seven million sixty thousand three hundred eleven |
ETIM
| ETIM 5.0 | EC001855 |
|---|---|
| ETIM 6.0 | EC001855 |
| ETIM 7.0 | EC001855 |