PHOENIX CONTACT SAC-8P-M12MS/60,0-PUR SH SAC-8P-M12MS/60,0-PUR SH 1553407 PHOENIX CONTACT Sensor/actuator cable, 8-pole, M12 straight connector, codi.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-8P-M12MS/60,0-PUR SH 1553407 PHOENIX CONTACT Sensor/actuator cable, 8-pole, M12 straight connector, codi..

SAC-8P-M12MS/60,0-PUR SH

1553407

PHOENIX CONTACT

5 Pcs.

Sensor/actuator cable, 8-pole, M12 straight connector, coding: A, to free cable end, cable length: 60 m Cable for sensors/actuators Sensor/actuator cable, 8-position, Plug straight M12, coding: A, connected with unwired, on free cable end, cable length: 60 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact model SAC-8P-M12MS/60,0-PUR SH is a sensor/actuator cable designed to facilitate reliable signal transmission between field devices and control systems in automated industrial setups. These factory-assembled lines provide the necessary physical link for sensors and actuators, maintaining signal integrity in complex machinery.

Exact pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Product type: Sensor/actuator cable
  • Number of positions: 8
  • Application: Standard
  • No. of cable outlets: 1
  • Shielded: yes
  • Coding: A
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Flammability rating according to UL 94: HB
  • Material of grip body: TPU, hardly inflammable, self-extinguishing
  • Contact material: CuZn
  • Contact surface material: Ni/Au
  • Contact carrier material: TPU GF
  • Material for screw connection: Zinc die-cast, nickel-plated
  • Contact resistance: ≤ 5 mΩ
  • Insulation resistance: ≥ 100 MΩ

More info

▲
Technical data

Product properties
Product typeSensor/actuator cable
Number of positions8
ApplicationStandard
No. of cable outlets1
Shieldedyes
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94HB
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties
Contact resistance≤ 5 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN30 V AC
30 V DC
Nominal current IN2 A
Protective circuitunwired

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayNo
Status display presentNo

Connector
Connection 1
TypePlug straight M12
Number of positions8
Coding typeA
Connection 2
Typefree cable end

Cable/line
Cable length60 m
PUR halogen-free black [PUR]
Dimensional drawing
Shieldedyes
UL AWM Style20549 / 10493 (80°C/300 V)
Cable weight53 kg/km
Cable typePUR halogen-free black
Short symbolLiF9YC11Y
Cable type (abbreviation)PUR
External cable diameter5.9 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorblack-gray RAL 7021
Thickness, outer sheathapprox. 0.5 mm
Conductor materialBare Cu litz wires
Conductor structure signal line32x 0.10 mm
AWG signal line24
Conductor cross section8x 0.25 mm² (Signal line)
Material wire insulationPP
Thickness, insulationapprox. 0.2 mm
Wire diameter incl. insulation1.17 mm ±0.02 mm
Single wire, colorbrown, white, green, yellow, gray, pink, blue, red
Overall twist8 wires around filler to the core
ShieldingTinned copper braided shield
Optical shield covering85 %
Nominal voltage, cable≤ 300 V AC
Test voltage Core/Shield≥ 2000 V AC (for 60 s)
Test voltage, cable≥ 3000 V AC (Spark test)
Cable resistance≤ 78 Ω/km (at 20 °C)
Cable insulation resistance≥ 1 GΩ*km (at 20 °C)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Number of bending cycles2000000
Minimum bending radius, drag chain applications10 x D
Traversing path10 m
Traversing rate3 m/s
Acceleration10 m/s²
Halogen-freein accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Resistance to oilin accordance with IEC 60811-404
Flame resistancein acc. with UL FT-2
according to UL 758/1581 (horizontal)
in accordance with UL 758/1581 FT2
According to DIN EN 60332-2-2 (20 s)
Other resistancehydrolysis and microbe resistant
Resistant to salt water
low-abrasion
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Special propertiesFlexible cable conduit capable
Ambient temperature (operation)-25 °C ... 80 °C (Cable, flexible installation)
-40 °C ... 80 °C (cable, fixed installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
-25 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (Cable, flexible installation)

Standards and regulations
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.