PHOENIX CONTACT SAC-8P-M12MS/20-513/M12FS SH8 SAC-8P-M12MS/20-513/M12FS SH8 1408750 PHOENIX CONTACT Sensor/actuator cable SAC-8P-M12MS/20-513/M12FS SH8 14.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-8P-M12MS/20-513/M12FS SH8 1408750 PHOENIX CONTACT Sensor/actuator cable SAC-8P-M12MS/20-513/M12FS SH8 14..

SAC-8P-M12MS/20-513/M12FS SH8

1408750

PHOENIX CONTACT

50 Pcs.

Sensor/actuator cable - SAC-8P-M12MS/20-513/M12FS SH8 - 1408750 Sensor/actuator cable, 8-pole, halogen-free, greyish-black RAL 7021, shielded, M12 straight male connector, encoding: A, to M12 straight connection female, coding: A, cable length: 20 m, Customer variant Sensor/actuator cable, 8-position, PUR halogen-free, black-gray RAL 7021, shielded, Plug straight M12, coding: A, on Socket straight M12, coding: A, cable length: 20 m, Customer version

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact SAC-8P-M12MS/20-513/M12FS SH8 sensor/actuator cable provides multi-conductor signal routing between distributed field devices and control system inputs. Extended-length shielded assemblies like this support complex automation nodes while minimizing noise disruption in industrial layouts. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Sensor/actuator cable
  • Number of positions: 8
  • No. of cable outlets: 1
  • Shielded: yes
  • Coding: A
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Flammability rating according to UL 94: HB
  • Seal material: NBR
  • Material of grip body: TPU, hardly inflammable, self-extinguishing
  • Contact material: CuZn
  • Contact surface material: Ni/Au
  • Contact carrier material: TPU GF
  • Material for screw connection: Zinc die-cast, nickel-plated
  • Insulation resistance: ≥ 100 MΩ
  • Nominal voltage U N: 30 V AC

More info

▲
Technical data

Product properties
Product typeSensor/actuator cable
Number of positions8
No. of cable outlets1
Shieldedyes
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94HB
Seal materialNBR
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties
Insulation resistance≥ 100 MΩ
Nominal voltage UN30 V AC
30 V DC
Nominal current IN2 A

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayno
Status display presentNo

Connector
Connection 1
TypePlug straight M12
Number of positions8
Coding typeA
Connection 2
TypeSocket straight M12
Number of positions8
Coding typeA

Cable/line
Cable length20 m
PUR halogen-free black [513]
Cable weight49 kg/km
UL AWM Style20549 / 10493 (80°C/300 V)
Number of positions7
Shieldedyes
Cable typePUR halogen-free black [513]
Conductor typeRound cable
Conductor structure signal line32x 0.10 mm
AWG signal line24
Conductor cross section7x 0.25 mm² (Signal line)
Wire diameter incl. insulation1.17 mm ±0.02 mm (Signal line)
External cable diameter6.00 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorblack-gray RAL 7021
Conductor materialBare Cu litz wires
Material, fillerPE
Material wire insulationPP
Single wire, colorwhite, brown, green, yellow, gray, pink, blue
Thickness, insulation≥ 0.21 mm
Thickness, outer sheath≥ 0.38 mm
Overall twistSeven wires around the filler to the core
Shielding materialAl19PES23
Max. conductor resistance≤ 78 Ω/km (at 20 °C)
Insulation resistance≥ 100 GΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation30 mm
Smallest bending radius, movable installation60 mm
Dynamic load capacity (bending)Max. bending cycles: 30000, Bending radius: 50 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s²
Halogen-freein accordance with DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
Flame resistancein accordance with DIN UL-Style 20549
in accordance with UL 758/1581 FT2
Resistance to oilin accordance with DIN EN 60811-2-1
Other resistancehydrolysis and microbe resistant
Resistant to salt water
Special propertiesnot suited to drag chain applications
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
-40 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (Cable, flexible installation)

Standards and regulations
Standard designationM12 connector

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.