View larger
SAC 8P-M M8FR/0,2-PUR/M12FR 1565464 PHOENIX CONTACT Sensor/actuator cable, 8-pole, Elbowed Female M8, to Elb..
SAC 8P-M M8FR/0,2-PUR/M12FR
1565464
PHOENIX CONTACT
100 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for compact machine architectures, the Phoenix Contact SAC 8P-M M8FR/0,2-PUR/M12FR sensor/actuator cable bridges disparate connector interfaces in complex control assemblies. This cable assembly routes power and telemetry data safely between multi-pin industrial peripherals. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles: 8
- Number of cable outlets: 1
- Armored: No
- Keying: A
- Insulation properties Degree of pollution: 3
- Flammability class according to UL 94: HB
- Plug Surface Material: TPU, flame retardant, self-extinguishing
- Contact material: CuSn
- Contact surface material: Ni/Au
- Contact holder material: TPU GF
- Screwed connection material: Zinc die-cast, nickel-plated
- Contact resistance: ≤ 5 mΩ
- Insulation resistance: ≥ 100 MΩ
- Rated voltage U N: 30 V AC
- Rated Current I N: 1.5 A
- Protection circuit: Disconnected
More info
▲| Number of poles | 8 |
| Number of cable outlets | 1 |
| Armored | No |
| Keying | A |
| Insulation properties | |
| Degree of pollution | 3 |
| Flammability class according to UL 94 | HB |
| Plug Surface Material | TPU, flame retardant, self-extinguishing |
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Contact holder material | TPU GF |
| Screwed connection material | Zinc die-cast, nickel-plated |
| Contact resistance | ≤ 5 mΩ |
| Insulation resistance | ≥ 100 MΩ |
| Rated voltage UN | 30 V AC |
| 30 V DC | |
| Rated Current IN | 1.5 A |
| Protection circuit | Disconnected |
| Status display | No |
| Presence of a status display | No |
| Connection 1 | |
| Type | M8 Angled Female Connector |
| Connection 2 | |
| Type | M12 Angled Female Connector |
| Number of poles | 8 |
| Coding Type | A |
| Cable length | 0.2 m |
| PUR free of black halogen [PUR] | |
| Dimensioned drawing | |
| Armored | No |
| Style UL AWM | 20549 |
| Sheath Weight | 31.4 kg/km |
| Type | PUR free of black halogen |
| Abbreviation | Li9Y11Y |
| Cable Type (Symbol) | PURE |
| Outer diameter of the cable | 5.1 mm ±0.15 mm |
| Outer Sheath, Material | PURE |
| Outer sheath, colour | grey-black RAL 7021 |
| Conductive material | Bare Cu Cord |
| Conductor structure signal line | 18x 0.10 mm |
| AWG Signal Line | 26 |
| Cable section | 8x 0.14 mm² (Signal Line) |
| Filling material | PE |
| Wire Insulating Material | PP |
| Insulation thickness | ≥ 0.21 mm (Signal Line) |
| Wire diameter with insulation | 1 mm ±0.02 mm (Signal Line) |
| Yarn, colour | white, brown, green, yellow, grey, pink, blue, red |
| Total wiring | 8 wires with 2 filling masses in the direction of the core |
| No wiring, total wiring | 58 mm |
| Rated cable voltage | ≤ 300 V AC |
| Test Voltage Cable | ≥ 3000 V AC (Spark Test) |
| Line Strength | 139 Ω/km (at 20 °C) |
| Line Insulation Resistance | 1 GΩ*km (at 20°C) |
| Minimum bending radius, fixed position | 5 x D |
| Minimum bend radius, flexible position | 10 x D |
| Number of bending cycles | 4000000 |
| Bend Radius | 51 mm |
| Race | 10 m |
| Movement speed | 3 m/s |
| Acceleration | 10 m/s² |
| Halogen-free | according to DIN VDE 0472 Part 815 |
| according to DIN EN 50267-2-1 | |
| Oil resistance | according to DIN EN 60811-2-1, 168 h at 100 °C |
| Resistance to flame spread | according to UL 758/1581 (horizontal) |
| to UL 758/1581 FT2 | |
| Special Resistance | Resistant to hydrolysis and microbes |
| seawater resistant | |
| Non-adhesive | |
| wear-resistant | |
| relatively UV-resistant according to DIN EN ISO 4892-2-A | |
| Ambient Temperature (Operating) | -25 °C ... 80 °C (Cable, Flexible Laying) |
| -40 °C ... 80 °C (cable, fixed installation) | |
| Environmental conditions | |
| Ingress protection | IP65 |
| IP67 | |
| Ambient Temperature (Operating) | -25 °C ... 90 °C (male/female connector) |
| M8 | |
| Designation of the standard | M8 connector |
| Standards/requirements | IEC 61076-2-104 |