PHOENIX CONTACT SAC-8P-60,0-PUR/M12FS SH SAC-8P-60,0-PUR/M12FS SH 1401207 PHOENIX CONTACT Sensor/actuator cable, 8-pole, halogen-free PUR, greyish bl.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-8P-60,0-PUR/M12FS SH 1401207 PHOENIX CONTACT Sensor/actuator cable, 8-pole, halogen-free PUR, greyish bl..

SAC-8P-60,0-PUR/M12FS SH

1401207

PHOENIX CONTACT

25 Pcs.

Sensor/actuator cable, 8-pole, halogen-free PUR, greyish black RAL 7021, shielded, free cable end, to straight female M12, coding: A, cable length: 60 m Sensor/actuator cable, 8-position halogen-free, shielded, free cable end, on Socket straight M12, coding: A, cable length: 60 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Configured for robust industrial communication, the SAC-8P-60,0-PUR/M12FS SH 1401207 PHOENIX CONTACT Sensor/actuator cable, 8-pole, halogen-free PUR, greyish bl.. bridges the gap between field-level devices and control cabinets. Pre-wired industrial cords deliver dependable connectivity for complex automated production lines and measurement networks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Sensor/actuator cable
  • Number of positions: 8
  • No. of cable outlets: 1
  • Shielded: yes
  • Coding: A
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Flammability rating according to UL 94: HB
  • Seal material: NBR
  • Material of grip body: TPU, hardly inflammable, self-extinguishing
  • Contact material: CuZn
  • Contact surface material: Ni/Au
  • Contact carrier material: TPU GF
  • Material for screw connection: Zinc die-cast, nickel-plated
  • Contact resistance: ≤ 5 mΩ
  • Insulation resistance: ≥ 100 MΩ

More info

▲
Technical data

Product properties
Product typeSensor/actuator cable
Number of positions8
No. of cable outlets1
Shieldedyes
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94HB
Seal materialNBR
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties
Contact resistance≤ 5 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN30 V
Nominal current IN2 A

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Signaling
Status displayNo
Status display presentNo

Connector
Connection 1
Typefree cable end
Connection 2
TypeSocket straight M12
Number of positions8
Coding typeA

Cable/line
Cable length60 m
PUR halogen-free black [PUR]
Dimensional drawing
Cable weight53 kg/km
UL AWM Style20549 / 10493 (80°C/300 V)
Number of positions8
Shieldedyes
Cable typePUR halogen-free black [PUR]
Conductor structure signal line32x 0.10 mm
AWG signal line24
Conductor cross section8x 0.25 mm² (Signal line)
Wire diameter incl. insulation1.17 mm ±0.02 mm
External cable diameter5.9 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorblack-gray RAL 7021
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorbrown, white, green, yellow, gray, pink, blue, red
Thickness, insulationapprox. 0.2 mm
Thickness, outer sheathapprox. 0.5 mm
Overall twist8 wires around filler to the core
Optical shield covering85 %
Max. conductor resistance≤ 78 Ω/km (at 20 °C)
Insulation resistance≥ 1 GΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V AC
Test voltage≥ 3000 V AC (Spark test)
Test voltage Core/Shield≥ 2000 V AC (for 60 s)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation30 mm
Smallest bending radius, movable installation59 mm
Max. bending cycles2000000
Halogen-freein accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Flame resistancein acc. with UL FT-2
according to UL 758/1581 (horizontal)
in accordance with UL 758/1581 FT2
According to DIN EN 60332-2-2 (20 s)
Resistance to oilin accordance with IEC 60811-404
Other resistancehydrolysis and microbe resistant
Resistant to salt water
low-abrasion
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Special propertiesFlexible cable conduit capable
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
-25 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (Cable, flexible installation)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.