PHOENIX CONTACT SAC-8P-5,0-PUR/M12FS SH NC SAC-8P- 5,0-PUR/M12FS SH NC 1402929 PHOENIX CONTACT Sensor/actuator cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-8P- 5,0-PUR/M12FS SH NC 1402929 PHOENIX CONTACT Sensor/actuator cable

SAC-8P-5,0-PUR/M12FS SH NC

1402929

PHOENIX CONTACT

50 Pcs.

Sensor/actuator cable Sensor/actuator cable, 8-pole, halogen-free PUR, grayish black RAL 7021, shielded, free cable end, to M12 straight connection female, coding: A, cable length: 5 m, Screen is not placed on the knurling

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Built to handle complex control signals, the SAC-8P- 5,0-PUR/M12FS SH NC 1402929 PHOENIX CONTACT Sensor/actuator cable from Phoenix Contact provides dependable connectivity in automated machine builds. These multi-conductor cable assemblies connect measurement instruments and feedback devices to industrial input modules. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Number of poles (EF001391): 8
  • Type of electrical connection, box-sided (EF005524): M12
  • Type of plug-in contact, box-sided (EF008386): Female (bus)
  • Positioning cable feed, box-sided (EF005927): Straight
  • Cable length (EF000536): 5 m
  • Halogen free (EF000025): Yes
  • With LED indication (EF005950): No
  • Screened (EF000881): Yes
  • Cable type (EF000081): Multi-core
  • Vulcanize (EF004115): No
  • Material contact body (EF008248): CuZn
  • Rated current In (EF008250): 2 A
  • Rated voltage (EF000228): 30 V
  • Degree of protection (IP) (EF005474): IP65

More info

▲

Key Commercial Data

Orderkey1402929
Packing unit1 pc
Minimum order quantity50 pc
NoteMade to Order (non-returnable)
GTIN4046356636940
Weight per Piece (excluding packing)276.000 g
Custom tariff number85444290
Country of originPL (Poland)

Dimensions

Length of cable5 m
Stripping length of the free conductor end50 mm

Ambient conditions

Degree of protectionIP65
IP67

General

Rated current at 40°C2 A
Rated voltage30 V AC
30 V DC
Number of positions8
Insulation resistance≥ 100 MΩ
CodingA - standard
Status displayNo
Overvoltage categoryII
Degree of pollution3
Insertion/withdrawal cycles≥ 100

Material

Flammability rating according to UL 94HB
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Material, knurlsZinc die-cast, nickel-plated
Sealing materialNBR

Standards and Regulations

Flammability rating according to UL 94HB

Cable

Cable typePUR halogen-free black
Cable type (abbreviation)PUR
Cable abbreviationLiF9YC11Y
UL AWM style20549 / 10493 (80°C/300 V)
Conductor cross section8x 0.25 mm² (Signal line)
AWG signal line24
Conductor structure signal line32x 0.10 mm
Core diameter including insulation1.17 mm ±0.02 mm
Thickness, insulationapprox. 0.2 mm
Wire colorsBrown, white, green, yellow, gray, pink, blue, red
Overall twist8 wires around filler to the core
ShieldingTinned copper braided shield
Optical shield covering85 %
External sheath, colorblack-gray RAL 7021
Outer sheath thicknessapprox. 0.5 mm
External cable diameter D5.9 mm ±0.2 mm
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Number of bending cycles2000000
Minimum bending radius, drag chain applications10 x D
Traversing path10 m
Traversing rate3 m/s
Acceleration10 m/s²
Cable weight53 kg/km
Outer sheath, materialPUR
Material conductor insulationPP
Conductor materialBare Cu litz wires
Insulation resistance≥ 1 GΩ*km (at 20 °C)
Conductor resistance≤ 78 Ω/km (at 20 °C)
Nominal voltage, cable≤ 300 V AC
Test voltage, cable≥ 3000 V AC (Spark test)
Test voltage Core/Shield≥ 2000 V AC (for 60 s)
Special propertiesFlexible cable conduit capable
Flame resistancein acc. with UL FT-2
according to UL 758/1581 (horizontal)
in accordance with UL 758/1581 FT2
According to DIN EN 60332-2-2 (20 s)
Halogen-freein accordance with DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
Other resistancehydrolysis and microbe resistant
Resistant to salt water
Low adhesion
Low adhesion
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (cable, flexible installation)

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.