View larger
SAC-8P-15,0-28X/M12FS SH OD 1421774 PHOENIX CONTACT Sensor/actuator cable SAC-8P-15,0-28X/M12FS SH OD 1421774
SAC-8P-15,0-28X/M12FS SH OD
1421774
PHOENIX CONTACT
25 Pcs.
Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact SAC-8P-15,0-28X/M12FS SH OD sensor/actuator cable is a specialized connection line used to link industrial sensors and control hardware in automated systems. These shielded assemblies ensure dependable signal and power delivery while protecting against electromagnetic interference in demanding factory environments.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 8
- Type of electrical connection, box-sided (EF005524): M12
- Type of plug-in contact, box-sided (EF008386): Female (bus)
- Positioning cable feed, box-sided (EF005927): Straight
- Cable length (EF000536): 15 m
- Halogen free (EF000025): Yes
- With LED indication (EF005950): No
- Screened (EF000881): Yes
- Cable type (EF000081): Multi-core
- Vulcanize (EF004115): No
- Material contact body (EF008248): CuSn
- Rated current In (EF008250): 2 A
- Rated voltage (EF000228): 30 V
- Degree of protection (IP) (EF005474): IP65
More info
▲Sensor/actuator cable, 8-position, PE-X/PE-X halogen-free, black-gray RAL 7021, shielded, cable length: 15 m, for outdoor applications, with high-grade steel knurl
Key Commercial Data
| Orderkey | 1421774 |
|---|---|
| Packing unit | 1 |
| GTIN | 4055626279688 |
| Custom tariff number | 85444290 |
Dimensions
| Length of cable | 15 m |
|---|
General
| Rated current at 40°C | 2 A |
|---|---|
| Rated voltage | 30 V AC |
| 30 V DC | |
| Number of positions | 8 |
| Coding | A - standard |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Status display | No |
| Protective circuit/component | unwired |
| Degree of pollution | 3 |
Material
| Flammability rating according to UL 94 | V0 |
|---|---|
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Contact carrier material | PP |
| Material of grip body | PP |
| Material, knurls | Stainless steel |
| Sealing material | FPM |
Standards and Regulations
| Standard designation | M12 connector |
|---|---|
| Standards/regulations | IEC 61076-2-101 |
| Flammability rating according to UL 94 | V0 |
Cable
| Cable type | PE-X black |
|---|---|
| Cable type (abbreviation) | 28X |
| Cable abbreviation | Li2X2X-C-V1-2X |
| Conductor cross section | 8x 0.25 mm² |
| AWG signal line | 24 |
| Conductor structure signal line | 32x 0.10 mm |
| Core diameter including insulation | 1.17 mm ±0.02 mm |
| Thickness, insulation | approx. 0.25 mm (Core insulation) |
| Wire colors | white, brown, green, yellow, gray, pink, blue, red |
| Overall twist | 8 wires around filler to the core |
| Length of twist, overall twist | 67 mm |
| Shielding | Braided copper wires |
| Optical shield covering | 85 % |
| External sheath, color | black-gray RAL 7021 |
| Inner sheath thickness | approx. 0.5 mm |
| Outer sheath thickness | approx. 0.7 mm |
| External cable diameter D | 7.25 mm ±0,3 mm |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Number of bending cycles | 1000000 |
| Minimum bending radius, drag chain applications | 10 x D |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Acceleration | 10 m/s² |
| Cable weight | 81 kg/km |
| Outer sheath, material | PE-X |
| Material, inner sheath | PE-X |
| Material, filler | PP yarn |
| Material conductor insulation | PE-X |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 100 MΩ*km (at 20 °C) |
| Conductor resistance | ≤ 78 Ω/km (at 20 °C) |
| Working capacitance | approx. 80 pF (core-core) |
| approx. 125 pF (core-shield) | |
| Nominal voltage, cable | ≤ 300 V AC |
| Test voltage, cable | ≥ 3000 V AC (Spark test) |
| Test voltage Core/Shield | ≥ 1000 V AC (for 10 s) |
| Special properties | Inductance approx. 0.48 mH/km |
| Irradiated | |
| Flame resistance | According to DIN EN 60332-1-2 |
| according to DIN EN 50266-2-5 | |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| in accordance with DIN EN 50267-2-1 | |
| Resistance to oil | According to DIN EN 60811-2-1, 168 h at 100°C |
| According to DIN EN 50306 | |
| Other resistance | Resistance to fuels according to IEC 60811, 168 h at 70°C |
| UV resistant according to DIN VDE 0276-605 | |
| Ambient temperature (operation) | -40 °C ... 105 °C (cable, fixed installation) |
| -15 °C ... 105 °C (cable, flexible installation) | |
| 20 °C ±5 °C (cable, drag chain applications) |
Environmental Product Compliance
| REACh SVHC | |
|---|---|
| Lead 7439-92-1 | |
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Classifications
eCl@ss
| eCl@ss 6.0 | 27279200 |
|---|---|
| eCl@ss 7.0 | 27279218 |
| eCl@ss 9.0 | 27060311 |
ETIM
| ETIM 5.0 | EC001855 |
|---|---|
| ETIM 6.0 | EC001855 |
| ETIM 7.0 | EC001855 |