PHOENIX CONTACT SAC-6P-M12MSM/ 3,0-PUR PE SAC-6P-M12MSM/ 3,0-PUR PE 1414953 PHOENIX CONTACT Power cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-6P-M12MSM/ 3,0-PUR PE 1414953 PHOENIX CONTACT Power cable

SAC-6P-M12MSM/ 3,0-PUR PE

1414953

PHOENIX CONTACT

1 Pcs.

Power cable Power cable, 6-pole halogen-free, M12 straight connector, coding: M, to free cable end, cable length: 3 m, for alternating current up to 8 A/690 V Power cable, 6-position, PUR halogen-free, black-gray RAL 7021, Plug straight M12, coding: M, on free cable end, cable length: 3 m, for AC current up to 8 A/690 V

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact power cable (SAC-6P-M12MSM/ 3,0-PUR PE) delivers secure electrical energy distribution to decentralized drives, motors, and high-load automation modules. Industrial power cordsets are built to handle higher current capacities while maintaining secure mechanical engagement under vibration.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Power cable
  • Application: Power supply
  • Number of positions: 6
  • No. of cable outlets: 1
  • Shielded: no
  • Coding: M
  • Data management status Article revision: 06
  • Insulation characteristics Overvoltage category: III
  • Degree of pollution: 3
  • Flammability rating according to UL 94: V0
  • Material of grip body: PP
  • Contact material: CuZn
  • Contact surface material: Ni/Au
  • Contact carrier material: PA
  • Material for screw connection: Zinc die-cast, nickel-plated
  • Insulation resistance: ≥ 100 MΩ

More info

▲
Technical data

Product properties
Product typePower cable
ApplicationPower supply
Number of positions6
No. of cable outlets1
Shieldedno
CodingM
Data management status
Article revision06
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Material of grip bodyPP
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialPA
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties
Insulation resistance≥ 100 MΩ
Nominal voltage UN690 V AC
Nominal current IN8 A

Connector
Connection 1
TypePlug straight M12
Coding typeM (Power)
Connection 2
Typefree cable end

Cable/line
Cable length3 m
PUR halogen-free black [PUR]
Dimensional drawing
Cable weight130 kg/km
Number of positions6
Shieldedno
Cable typePUR halogen-free black [PUR]
Conductor cross section6x 1.5 mm²
Wire diameter incl. insulation2.35 mm ±0.1 mm
External cable diameter8.80 mm ±0.25 mm
Outer sheath, materialPUR
External sheath, colorblack-gray RAL 7021
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorblack 1, black 2, black 3, black 4, black 5, green/yellow
Thickness, insulation≥ 0.36 mm
Thickness, outer sheathapprox. 0.90 mm
Max. conductor resistance≤ 14.1 Ω/km (at 20 °C)
Insulation resistance≥ 1 GΩ*km (at 20 °C)
Nominal voltage, cable≤ 1000 V AC
Test voltage≥ 3000 V AC (Spark test)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation44 mm
Smallest bending radius, movable installation88 mm
Dynamic load capacity (bending)Max. bending cycles: 4000000, Bending radius: 10xD, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s²
Halogen-freein accordance with DIN VDE 0472 part 815
according to DIN EN 60754-1
Flame resistancein accordance with UL 758/1581 FT2
according to DIN EN 60332-2-2
Resistance to oilaccording to DIN EN 60811-404, 168 h at 100 °C
Other resistanceHydrolysis and microbe resistant as per VDE 0282 section 10
Low adhesion
abrasion-resistant
Resistant to salt water
Ambient temperature (operation)-50 °C ... 85 °C (cable, fixed installation)
-30 °C ... 85 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67 (without preloading, as additional test in accordance with IEC 60529)
Ambient temperature (operation)-25 °C ... 85 °C (Plug / socket)

Standards and regulations
Standard designationM12 connector
Standards/specificationsIEC 61076-2-111

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.